[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-662348-105":59,"doc-detail-662348-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","desert-aire-cm3530-series-controller-installation-and-operations-manual-for-lclv-units","Desert Aire CM3530 Series Controller - Installation and Operations Manual for LC/LV Units","","Desert Aire CM3530 Series Controller installation and operations manual for LC/LV dehumidification units, including safety cautions, interface and control capabilities, and system communication options such as LonWorks, BACnet Ethernet, BACnet MS/TP, and Modbus. The document covers alarm history retention and remote access capability, along with warranty terms detailing coverage duration, required installation and start-up reporting, exclusions, and conditions for valid service and repairs. It also provides key product warnings and a structured table of contents for installation topics.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/desert-aire-cm3530-series-controller-installation-and-operations-manual-for-lclv-units/662348/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/desert-aire-cm3530-series-controller-installation-and-operations-manual-for-lclv-units/662348.png","ImageObject",300,407,{"name":92,"@type":93},"Franzy","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What communication protocols are supported by the CM3530 controller?","Question",{"text":112,"@type":113},"The manual lists LonWorks, BACnet Ethernet, BACnet MS/TP, and Modbus as supported communication options.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What is required to validate the standard limited warranty?",{"text":117,"@type":113},"The Start-Up Report must be completed and returned to Desert Aire Service for evaluation. If no deficiencies are identified, a Warranty Validation Letter is issued; otherwise, installation or start-up deficiencies must be corrected and communicated to activate warranty.",{"name":119,"@type":110,"acceptedAnswer":120},"Which items are excluded from the standard limited warranty?",{"text":121,"@type":113},"Excluded components include belts, filters, driers, fuses, and refrigerant. The manual also excludes coils or components that corrode due to improperly balanced pool chemistry or corrosive air quality.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},662348,1793212734,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144},2336478945519,"https://ap-avatar.wpscdn.com/davatar_085a072bc5b1113ac321206ff7593b45","Backlit LCD User Interface  \nCustom programming for complex dehumidification temperature & humidity control  \nMultiple communication options:  \n-LonWorks®  \n-BACnet™ Ethernet  \n-BACnet™ MS/TP  \n-Modbus®  \nAlarm history retention  \nIntegral remote access capability  \nCM3530 Series Controller  \nInstallation and Operations Manual for LC/LV Units  \n| |\n| --- |\n| ONLY TRAINED, QUALIFIED PERSONNEL SHOULD INSTALL AND/OR SERVICE\u003Cbr>DESERT AIRE EQUIPMENT. SERIOUS INJURY, DEATH AND PROPERTY DAMAGE CAN RESULT FROM IMPROPER INSTALLATION/SERVICE OF THIS EQUIPMENT. HIGH VOLTAGE\u003Cbr>ELECTRICAL COMPONENTS AND REFRIGERANT UNDER PRESSURE ARE PRESENT. |\n\nDesert Aire  \nDehumidification Equipment Standard Limited Warranty  \nDesert Aire warrants the dehumidifying unit to be free from defects in materials and workmanship subject to the terms, conditions and limitations stated herein.  \nTERMS  \nDesert Aire warrants all components (except as noted) for a period of two (2) years from the date of shipment. This warranty shall be limited to the supply of new or rebuilt parts for the part which has failed because of  \ndefects in workmanship or material, and does not include the cost for labor, transportation or other costs not herein provided for. Replaced parts are warranted only for the remaining portion of the original warranty period.  \nCONDITIONS  \nThe warranty is subject to the following conditions:  \n1. The unit must be properly installed and maintained in accordance with the Desert Aire“Installation and Operation Manual” provided with each unit and/or other documentation provided.  \n2. The Start-Up Report must be completed and returned to Desert Aire Service for evaluation. If no deficiencies are identified a Warranty Validation Letter will be issued that provides all warranty dates and coverage. If installation or start-up deficiencies are present, these must be corrected and communicated to Desert Aire in order to activate warranty.  \n3. This warranty shall not apply to any part that has been tampered with, or has been subject to misuse, negligence or accident. A warranty can be obtained for altered equipment but only with written consent from Desert Aire.  \n4. The following parts and components are excluded from the warranty: belts, filters, driers, fuses and refrigerant.  \n5. Refrigerant coils or other components that corrode due to improperly balanced pool chemistry or corrosive air quality will not be warranted.  \n6. All replacements or repairs will be FOB Germantown, WI.  \n7. This warranty shall be null and void if defects or damages result from unauthorized opening of the refrigerant circuit, tampering with factory set controls, or operating outside the original design conditions.  \n8. Desert Aire shall not be liable for labor costs incurred in diagnosing the problem, or the removal or replacement of the part or parts being repaired.  \n9. Desert Aire must preauthorize all warranty coverage described herein.  \nDesert Aire-CM3530 Manual 3  \nExtended Warranty:  \nYour Desert Aire unit may have extended warrantees beyond this Standard Limited Warranty document.  \nExtended warrantees are only available at the time of the purchase of the original equipment. These extended warrantees are covered under a separate document and their terms and conditions are separate from this document. It is mentioned in this document for informational purposes only. Any Extended Warranties will be identified on the Warranty Validation Letter.  \nAny and all incidental or consequential damages are expressly excluded from this warranty. Some states do not allow the exclusion of incidental or consequential damages for personal injury, so the above limitations may not apply to you for certain damages. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. No person or representative is authorized to make any warranty or assume any liability not strictly in accordance with the aforementioned.  \nInquiries regardin","cbCaigeSNnAUyBTZ","https://ap.wps.com/l/cbCaigeSNnAUyBTZ","pdf",3188325,54,"English","# Installation\n## Introduction\n## Sensor Installation\n## Auxiliary Air Heating Control Wiring\n## CM3530 Controller Overview\n# LC / LV Controller Details","[{\"question\":\"What communication protocols are supported by the CM3530 controller?\",\"answer\":\"The manual lists LonWorks, BACnet Ethernet, BACnet MS/TP, and Modbus as supported communication options.\"},{\"question\":\"What is required to validate the standard limited warranty?\",\"answer\":\"The Start-Up Report must be completed and returned to Desert Aire Service for evaluation. If no deficiencies are identified, a Warranty Validation Letter is issued; otherwise, installation or start-up deficiencies must be corrected and communicated to activate warranty.\"},{\"question\":\"Which items are excluded from the standard limited warranty?\",\"answer\":\"Excluded components include belts, filters, driers, fuses, and refrigerant. The manual also excludes coils or components that corrode due to improperly balanced pool chemistry or corrosive air quality.\"}]","Desert Aire CM3530 Series Controller - Installation and Operations Manual for LC/LV Units | PDF",136]