[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-403320-105":59,"doc-detail-403320-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","department-of-environmental-quality-air-quality-division-activity-report-scheduled-inspection-p0344","DEPARTMENT OF ENVIRONMENTAL QUALITY - AIR QUALITY DIVISION - ACTIVITY REPORT: Scheduled Inspection - P0344","","Activity report for an Air Quality Division scheduled inspection of Ground Effects LLC (SRN/ID: P0344) in Dearborn, Michigan, dated 01/11/2018. The report documents facility background, operating conditions, spray-on bed liner coating process, and personnel present. It records prior compliance issues from PTI 59-12 and related violations resolved via PTI 59-12A and removal of a heated cold cleaner. It also notes no current complaints on file.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/department-of-environmental-quality-air-quality-division-activity-report-scheduled-inspection-p0344/403320/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/department-of-environmental-quality-air-quality-division-activity-report-scheduled-inspection-p0344/403320.png","ImageObject",300,407,{"name":92,"@type":93},"Genevieve","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-28","2026-09-27",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What facility was inspected and what was its location?","Question",{"text":112,"@type":113},"Ground Effects LLC in Dearborn, Michigan (15200 Commerce Dr North).","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What is the coating process described in the report?",{"text":117,"@type":113},"The spray-on bed liner is applied robotically in designated spray booths using Component A (urethane pre-polymer) and Component B reacting to form a protective coating, with bed preparation using isopropyl alcohol (Prep Wash).",{"name":119,"@type":110,"acceptedAnswer":120},"Were there prior noncompliance issues, and how were they resolved?",{"text":121,"@type":113},"Yes. In 2016 the facility was determined noncompliant with several PTI 59-12 emission limits and cold cleaner requirements, followed by a violation notice. The violations were resolved through PTI 59-12A issuance on 11/22/2017 and removal of the heated cold cleaner.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},403320,1792170644,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":24,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144,"preview_page_count":19,"preview_urls":145},1374391974585,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","# DEPARTMENT OF ENVIRONMENTAL QUALITYAIR QUALITY DIVISIONACTIVITY REPORT:Scheduled Inspection\n\nP034443118  \n\n| FACILITY:GROUNDEFFECTS,LLC   | SRN/ID:P0344   |\n| --- | --- |\n| LOCATION:15200 COMMERCE DR NORTH,DEARBORN   | DISTRICT:Detroit   |\n| CITY:DEARBORN   | COUNTY:WAYNE   |\n| CONTACT:Jack Preston,Plant Manager   | ACTIVITY DATE:01/11/2018   |\n| COMPLIANCE STATUS:Compliance  \u003Cbr>STAFF:Todd Zynda   | SOURCE CLASS:SM OPT OUT   |\n| SUBJECT:Scheduled Inspection   |  |\n| RESOLVED COMPLAINTS:   |  |\n\nREASON FOR INSPECTION:Scheduled InspectionINSPECTED BY:Todd Zynda,AQD  \nPERSONNEL PRESENT:Jack Preston,Plant Manager;Grover Thomas,Environmental Engineer,BrooksPattison,Quality Manager  \nFACILITY PHONE NUMBER:313-462-2290FACILITY WEBSITE:www.gfxltd.com  \n## FACILITY BACKGROUND\n\nGround Effects LLC(Ground Effects)completes spray-on bed liners for the Ford F-150.Ground Effects islocated in the City of Dearborn,at 15200 Commerce Drive North in a primarily industrial and commercial area.The nearest residential property is located approximately 850 feet to the west southwest.  \nCurrently the facility has approximately 170 employees.The facility operates two 10-hour shifts,Monday throughFriday,1 shift on Saturday,and one shift on Sunday.Hours are subject to change depending on the Ford F-150production  \nThe facility operates the spray-on bed liner coating lines under permit to install(PTI)59-12A.The permit includesenforceable limits for hazardous air pollutants(HAPs)to restrict the facility's potential to emit(PTE)to less thanthe National Emission Standards for Hazardous Air Pollutants(NESHAP),Part 63,Subpart MMMM and lessthan the major source threshold to opt out of the Renewable Operating Permit(ROP)program.  \n## PROCESS OVERVIEW\n\nThe facility operates three spray-on bed liner coating lines.Each coating line contains its own designated spraybooth,where the spray-on bed liner is applied robotically.The spray-on bed liner application process consists oftwo component coating application.Component A consists of urethane pre-polymer which reacts with amines inComponent B to form a thick protective coating.Prior to coating application,the beds are prepared by washingwith an isopropyl alcohol (IPA)solution(Prep Wash).The exterior portion of the vehicle that does not receivespray coating,is tarped and taped off to protect the exterior finish.The bonding agent,which previously used tobe hand painted on_prior to the paint booth,is now applied robotically in the spray booth,prior to Component Aand B application.Following application of the spray-on bed liner,the trucks are air dried before transporting tothe customer(Ford).  \nThe facility also operates a parts washer and a small enclosed cabinet for grinding residual pieces of spray-on  \nbed liner for reuse during touch-up.  \n## COMPLAINTICOMPLIANCE HISTORY\n\nThere are no complaints for this facility on file.  \nDuring the inspection on January 28,2016,the facility was determined to be in noncompliance with severalemission limits of PTI 59-12(VOC limits and hexamethylene-1,6-diisocyanate limit).In addition,the cold cleanerat the facility was not in compliance with R336.1707(3)(a)and R336.1707(4).On February 29,2016 a violationnotice was issued for the identified violations.The violations were resolved through the issuance of PTI 59-12Aon November 22,2017 and the removal of the heated cold cleaner.  \nDuring the inspection on August 15,2013,the facility was determined to be in compliance with applicable permitconditions and regulations.  \nhttp://intranet.deq.state.mi.us/maces/WebPages/ViewActivityReport.aspx?ActivityID=246..3/26/2018  \n## OUTSTANDING CONSENT ORDERS\n\nNone  \nOUTSTANDING VNs  \nNone  \n## INSPECTION NARRATIVE\n\nOn January 11,2018 the Michigan Department of Environmental Quality(MDEQ)Air Quality Division(AQD)inspector,Mr.Todd Zynda,conducted an inspection of Ground Effects.During the inspection,Mr.Jack Preston,Plant Manager,Mr.Grover Thomas,Environmental Engineer,and Mr.Brooks Pattison,Quality","cbCaii7AmpaZVZAg","https://ap.wps.com/l/cbCaii7AmpaZVZAg","pdf",566220,"English","# Facility Background\n# Process Overview\n# Complaint Compliance History\n# Outstanding Consent Orders\n# Inspection Narrative","[{\"question\":\"What facility was inspected and what was its location?\",\"answer\":\"Ground Effects LLC in Dearborn, Michigan (15200 Commerce Dr North).\"},{\"question\":\"What is the coating process described in the report?\",\"answer\":\"The spray-on bed liner is applied robotically in designated spray booths using Component A (urethane pre-polymer) and Component B reacting to form a protective coating, with bed preparation using isopropyl alcohol (Prep Wash).\"},{\"question\":\"Were there prior noncompliance issues, and how were they resolved?\",\"answer\":\"Yes. In 2016 the facility was determined noncompliant with several PTI 59-12 emission limits and cold cleaner requirements, followed by a violation notice. The violations were resolved through PTI 59-12A issuance on 11/22/2017 and removal of the heated cold cleaner.\"}]","DEPARTMENT OF ENVIRONMENTAL QUALITY - AIR QUALITY DIVISION - ACTIVITY REPORT: Scheduled Inspection - P0344 | PDF",1790538881,13,[146,150,154,158],{"page_no":8,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/68bc42a038d5934a39978dce27c49aac.webp",983,1272,{"page_no":14,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/3cabce1d95ef6acc3b24d1b00a284e02.webp",982,1270,{"page_no":81,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/31977c95dc73263f527e0d300820bf33.webp",981,1269,{"page_no":19,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/ca26c4fffcbacd8ba49b0ec6973ae757.webp",980,1268]