[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-652957-105":59,"doc-detail-652957-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","deadfront-distribution-switchboards-600v-or-less-installation-operation-maintenance-manual","DEADFRONT DISTRIBUTION SWITCHBOARDS 600V OR LESS - Installation, Operation & Maintenance Manual","","Installation, operation, and maintenance manual for DEADFRONT DISTRIBUTION SWITCHBOARDS (600V OR LESS). Covers switchboard storage and handling conditions, site location and required clearances, wiring and grounding/bonding procedures, conduit and conductor installation, inspection and maintenance steps, and energizing requirements for qualified personnel. Includes limited warranty terms, implementation conditions, and limitations on responsibility, specifying defect correction options, time limits, and exclusions related to access, transportation, and unauthorized work.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/deadfront-distribution-switchboards-600v-or-less-installation-operation-maintenance-manual/652957/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/deadfront-distribution-switchboards-600v-or-less-installation-operation-maintenance-manual/652957.png","ImageObject",300,407,{"name":92,"@type":93},"jayni","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-24",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What time limits apply to the equipment limited warranty after shipment?","Question",{"text":112,"@type":113},"The warranty covers defects that appear within one year after shipment. If installation is handled by the manufacturer and the purchaser does not delay installation, the one-year period runs from completion of installation; in any case the total warranty period does not exceed 18 months from shipment.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What conditions can void the warranty when service help is required?",{"text":117,"@type":113},"Service should be requested immediately through the service department, and no unauthorized charges or expenses should be incurred. Making unauthorized corrections or performing unauthorized work voids the warranty and renders reimbursement impossible.",{"name":119,"@type":110,"acceptedAnswer":120},"What safety and qualification requirements are required before energizing and during maintenance?",{"text":121,"@type":113},"The manual emphasizes danger and hazardous voltage safety and requires qualified personnel for inspection/maintenance and for energizing. It also specifies steps such as tightening electrical connections and performing insulation resistance testing before energizing.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},652957,1793052189,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":41},3985747859343,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","American Midwest Power  \nSolutions for Power  \nDEADFRONT DISTRIBUTION SWITCHBOARDS 600V OR LESS  \nINSTALLATION OPERATION & MAINTENANCE MANUAL  \nAMP is the premier manufacturer of standard & custom electrical distribution products, committed to finding you Solutions For Power.  \nAmerican Midwest Power  \n3131 Vicksburg Lane Plymouth, MN 55447  \n[www.ampmfg.com](www.ampmfg.com)[ ](www.ampmfg.com)(800) 328-8658  \nTABLE OF CONTENTS  \nSection 1  \nSection 2  \nSection 3  \nLimited Warranty  \nWarranty Implementations and Conditions Handling  \nCare in Handling Upright Position Concealed Damage Shipping Skid Fork Lifting Overhead Hoisting  \nRigid Spreaders and Spanner Bars Unequal Weight Distribution Safety Hooks or Shackles  \nStorage  \nClean and Dry Space Outdoor Switchboards  \nUn-Energized Switchboards Should Be Kept Dry  \nInstallation of Switchboard  \nLocation  \nClearance From Walls/Working Clearance Conduit Raceways  \nBolt Sections Together Leveling and Securing Splice Plates  \nInternal Cabling & Cabling Between Sections  \nGrounding and Bonding Service Entrance Grounding Neutral Disconnection Link Unused Openings  \nService Conditions  \nSection 4  \nSection 5  \nSection 6  \nSection 7  \nInstallation of Conduit and Conductors  \nPrevent Moisture from Entering Conductor Locations  \nCable Lashing  \nProper Wiring Methods  \nBefore Energizing  \nTighten Electrical Connections Insulation Resistance Testing  \nBus Mounting Enclosure  \nOperating Mechanisms Ground Fault Systems Foreign Material Covers & Doors  \nEnergizing  \nQualified Personnel No Load on Switchboard Sequence of Energizing  \nMaintenance  \nDanger–Hazardous Voltage Safety  \nQualified Personnel  \nSwitchboard Inspection/Maintenance Cleaning  \nInspect All Electrical Joints & Terminations Fuse Clip Contact Pressure  \nCorrect Device Ratings Operate Devices Lubrication  \nInsulators and Insulating Material Interior Moisture and Condensation Severe Electrical Short Circuit Ground Fault Protection  \nLIMITED WARRANTY  \nAmerican Midwest Power warrants that the equipment delivered by it will be of the kind and quality described in the order or contract and will be free of defects in workmanship and material. Should any failure to conform to this warranty appear within one year after date of shipment, American Midwest Power shall, upon prompt notification, with the knowledge that the equipment has been stored, installed, operated and maintained in accordance with American Midwest Power recommendations and standard industry practice, correct such nonconformities, at its option, either by repairing any defective part or parts or by supplying a repaired or replacement part or parts F.O.B. factory. However, if American Midwest Power has installed the equipment or furnished field engineering services with respect to its installation, and if the Purchaser has not delayed the installation, the one-year shall run from the completion of the installation. The total warranty period shall not exceed 18 months from the date of shipment in any case.  \nIn no event shall American Midwest Power be responsible for providing working access to the defect, including the removal, disassembly, replacement or reinstallation of any equipment, materials or structures to the extent necessary to permit American Midwest Power to perform its warranty obligations, or transportation costs to and from the American Midwest Power factory. The conditions of any tests shall be mutually agreed upon and American Midwest Power shall be notified of, and may be present at all tests that may be made.  \nThe warranties set forth in this provision are exclusive and in lieu of all other warranties whether statutory, express or implied (including all warranties of merchantability and fitness for particular purpose and all warranties arising from course of dealing or usage of trade), except of title and against patent infringement. The remedies provided above are the Purchaser's sole remedies for any failure of American Midwest Power to comply with","cbCait23BxeB2S8f","https://ap.wps.com/l/cbCait23BxeB2S8f","pdf",1456321,12,"English","# Installation of Switchboard\n## Location\n## Clearance From Walls / Working Clearance\n## Conduit Raceways\n## Bolt Sections Together, Leveling and Securing Splice Plates\n## Internal Cabling & Cabling Between Sections\n## Grounding and Bonding\n## Service Conditions\n# Installation of Conduit and Conductors\n## Prevent Moisture from Entering Conductor Locations\n## Cable Lashing\n## Proper Wiring Methods\n# Before Energizing\n## Tighten Electrical Connections\n## Insulation Resistance Testing\n# Bus Mounting Enclosure\n## Operating Mechanisms\n## Energizing\n# Maintenance\n## Switchboard Inspection / Maintenance\n## Cleaning\n## Inspect All Electrical Joints & Terminations\n## Lubrication\n## Insulators and Insulating Material\n## Ground Fault Protection\n# Limited Warranty","[{\"question\":\"What time limits apply to the equipment limited warranty after shipment?\",\"answer\":\"The warranty covers defects that appear within one year after shipment. If installation is handled by the manufacturer and the purchaser does not delay installation, the one-year period runs from completion of installation; in any case the total warranty period does not exceed 18 months from shipment.\"},{\"question\":\"What conditions can void the warranty when service help is required?\",\"answer\":\"Service should be requested immediately through the service department, and no unauthorized charges or expenses should be incurred. Making unauthorized corrections or performing unauthorized work voids the warranty and renders reimbursement impossible.\"},{\"question\":\"What safety and qualification requirements are required before energizing and during maintenance?\",\"answer\":\"The manual emphasizes danger and hazardous voltage safety and requires qualified personnel for inspection/maintenance and for energizing. It also specifies steps such as tightening electrical connections and performing insulation resistance testing before energizing.\"}]","DEADFRONT DISTRIBUTION SWITCHBOARDS 600V OR LESS - Installation, Operation & Maintenance Manual | PDF",1792884675]