[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-662323-105":3,"detail-sidebar-cat-0-en-105":85,"doc-detail-662323-en":134},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":78,"head_meta":80,"extra_data":82,"updated_unix":84},105,"en","dc-inverter-free-installation-manual","DC INVERTER FREE - Installation Manual","","DC inverter free air conditioner installation instructions guide the correct setup process from unpacking and preliminary precautions to outdoor unit installation, refrigerant piping, electrical wiring, and test running. The manual emphasizes safety measures such as authorized installation, correct power-off procedures before electrical work, proper cable connection, grounding, and preventing moisture or contaminants from entering the refrigeration cycle. Special requirements for R410A refrigerant, leak detection, ventilation, and customer handover are included, alongside a list of required tools and checklists for attached fittings.",{"@graph":14,"@context":77},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/dc-inverter-free-installation-manual/662323/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/dc-inverter-free-installation-manual/662323.png","ImageObject",300,407,{"name":42,"@type":43},"Bintang","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-29","2026-10-28",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",5,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69,73],{"name":60,"@type":61,"acceptedAnswer":62},"Who should install or maintain the air conditioner?","Question",{"text":63,"@type":64},"Use an authorized dealer or a qualified installation professional to install or maintain the air conditioner.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"What safety steps must be taken before electrical work?",{"text":68,"@type":64},"Turn off the main power supply switch or breaker, and confirm all power switches are off before attempting any electrical work.",{"name":70,"@type":61,"acceptedAnswer":71},"Why is R410A special during installation?",{"text":72,"@type":64},"This unit uses R410A refrigerant, which has higher pressure than R22 and requires ensuring water, dust, former refrigerant, or refrigerating oil does not enter the refrigeration cycle.",{"name":74,"@type":61,"acceptedAnswer":75},"What should be done if refrigerant gas leaks during installation?",{"text":76,"@type":64},"Ventilate the room immediately. If leaked refrigerant gas comes into contact with fire, noxious gas may generate.","https://schema.org",{"og:url":32,"og:type":79,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":81,"canonical":32},"index,follow",{"doc_id":83,"site_id":7},662323,1793211787,{"code":4,"msg":86,"data":87},"success",[88,92,96,100,104,108,113,118,123,126,130],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},"Exam",70,"exam",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":101,"show_sort_weight":102,"slug":103},"Comic",60,"comic",{"id":105,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":106,"slug":107},6,50,"technology",{"id":109,"doc_module":4,"doc_module_name":25,"category_name":110,"show_sort_weight":111,"slug":112},7,"Healthcare",40,"healthcare",{"id":114,"doc_module":4,"doc_module_name":25,"category_name":115,"show_sort_weight":116,"slug":117},8,"Research & Report",30,"research-report",{"id":119,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":121,"slug":122},9,"Religion & Spirituality",20,"religion-spirituality",{"id":121,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":121,"slug":125},"World Cup","world-cup",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":127,"slug":129},10,"Lifestyle","lifestyle",{"id":131,"doc_module":4,"doc_module_name":25,"category_name":132,"show_sort_weight":55,"slug":133},19,"General","general",{"code":4,"msg":86,"data":135},{"doc_id":83,"user_id":136,"nickname":42,"user_avatar":137,"doc_module":4,"category_id":105,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":138,"file_id":139,"file_url":140,"file_type":141,"file_size":142,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":143,"language":144,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":145,"faqs":146,"seo_title":147,"seo_description":12,"update_tm":84,"read_time":111},962085564381,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","INSTALLATION MANUAL  \nDC INVERTER FREE  \nThank you very much for purchasing our air conditioner,  \nBefore using your air conditioner, please read this manual carefully and keep it for future reference.  \nCONTENTS PAGE  \nPRECAUTIONS........................................................................................1  \nATTACHED FITTINGS..............................................................................2  \nOUTDOOR UNIT INSTALLATION..............................................................3  \nINSTALL THE CONNECTING PIPE............................................................4  \nELECTRICAL WIRING..............................................................................9  \nTEST RUNNING.....................................................................................11  \nPRECAUTIONS ON REFRIGERANT LEAKAGE.........................................12  \nTURN OVER TO CUSTOMER..................................................................12  \nCUSTOMER DETAILS............................................................................13  \n1. PRECAUTIONS  \nCAUTION  \nNew Refrigerant Air Conditioner Installation  \nTHIS AIR CONDITIONER ADOPTS THE NEW HFC  \nREFRIGERANT(R410A)WHICH DOES NOT DESTROY OZONE  \nLAYER.  \nThe characteristics of R410A refrigerant are; Hydrophilic, oxidizing membrane or oil, and its pressure is approx.1.6 times higher than that of refrigerant R22.Accompanied with the new refrigerant, refrigerating oil has also been changed ,Therefore, during installation work, be sure that water, dust, former refrigerant, or refrigerating oil does not enter the refrigerating cycle. To prevent charging an incorrect refrigerant and refrigerating oil, the sizes of connecting sections of charging port of the main unit and installation tools are charged from those for the conventional refrigerant.  \nAsk an authorized dealer or qualified installation professional to install/maintain the air conditioner.  \nInappropriate installation may result in water leakage,electric shock or fire.  \nTurn off the main power supply switch or breaker before attempting any electrical work.  \nMake sure all power switches are off. Failure to do so may cause electric shock.  \nConnect the connecting cable correctly.  \nIf the connecting cable is connected in a wrong way, electric parts may be damaged.  \nWhen moving the air conditioner for the installation into another place, be very careful not to enter any gaseous matter other than the specified refrigerant into the refrigeration cycle.  \nIf air or any other has is mixed in refrigerant, the gas pressure in the refrigeration cycle becomes abnormally high and it may resultingly causes pipe burst and injuries on persons.  \nDo not modify this unit by removing any of the safety guards or by by-passing any of the safety interlock switches.  \nExposure of unit to water or other moisture before installation may cause a short-circuit of electrical parts.  \nDo not store it in a wet basement or expose to rain or water.  \nAfter unpacking the unit, examine it carefully if there are possible damage.  \nDo not install in a place that might increase the vibration of the unit.  \nTo avoid personal injury (with sharp edges), be careful when handling parts.  \nPerform installation work properly according to the Installation Manual.  \nInappropriate installation may result in water leakage, electric shock or fire.  \nWhen the air conditioner is installed in a small room, provide appropriate measures to ensure that the concentration of refrigerant leakage occur in the room does not exceed the critical level.  \nInstall the air conditioner securely in a location where the base can sustain the weight adequately.  \nPerform the specified installation work to guard against an earthquake.  \nIf the air conditioner is not installed appropriately, accidents may occur due to the falling unit.  \nIf refrigerant gas has leaked during the installation work, ventilate the room immediately.  \nIf the leaked refrigerant gas comes","cbCaicA9C3PrncJ7","https://ap.wps.com/l/cbCaicA9C3PrncJ7","pdf",6949293,16,"English","# PRECAUTIONS\n## New Refrigerant Air Conditioner Installation\n# ATTACHED FITTINGS\n# OUTDOOR UNIT INSTALLATION\n# INSTALL THE CONNECTING PIPE\n# ELECTRICAL WIRING\n# TEST RUNNING\n# PRECAUTIONS ON REFRIGERANT LEAKAGE\n# TURN OVER TO CUSTOMER\n# CUSTOMER DETAILS","[{\"question\":\"Who should install or maintain the air conditioner?\",\"answer\":\"Use an authorized dealer or a qualified installation professional to install or maintain the air conditioner.\"},{\"question\":\"What safety steps must be taken before electrical work?\",\"answer\":\"Turn off the main power supply switch or breaker, and confirm all power switches are off before attempting any electrical work.\"},{\"question\":\"Why is R410A special during installation?\",\"answer\":\"This unit uses R410A refrigerant, which has higher pressure than R22 and requires ensuring water, dust, former refrigerant, or refrigerating oil does not enter the refrigeration cycle.\"},{\"question\":\"What should be done if refrigerant gas leaks during installation?\",\"answer\":\"Ventilate the room immediately. If leaked refrigerant gas comes into contact with fire, noxious gas may generate.\"}]","DC INVERTER FREE - Installation Manual | PDF"]