[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-646008-105":59,"doc-detail-646008-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","dayton-portable-oil-fired-heaters-operating-instructions-and-parts-manual-models-2e510d-2e511d-3e218d-and-3e219c","Dayton Portable Oil-Fired Heaters - Operating Instructions and Parts Manual - Models 2E510D, 2E511D, 3E218D, and 3E219C","","Operating Instructions and Parts Manual for Dayton portable oil-fired heaters covers models 2E510D, 2E511D, 3E218D, and 3E219C. It provides safety-focused guidance for assembly, installation, operation, and maintenance, including carbon monoxide risk, proper fueling procedures, and warning definitions. The manual includes unpacking steps, general specifications (ratings, fuel, capacities, motor RPM), shipping/weight figures, and electrical specifications (input and amperage).",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/dayton-portable-oil-fired-heaters-operating-instructions-and-parts-manual-models-2e510d-2e511d-3e218d-and-3e219c/646008/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/dayton-portable-oil-fired-heaters-operating-instructions-and-parts-manual-models-2e510d-2e511d-3e218d-and-3e219c/646008.png","ImageObject",300,407,{"name":92,"@type":93},"LangkahRina","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-10","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":39},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the intended use of the Dayton portable oil-fired heaters in this manual?","Question",{"text":112,"@type":113},"The heaters are primarily intended for indoor and outdoor temporary heating of buildings under construction, alteration, or repair.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What fueling rules does the manual emphasize?",{"text":117,"@type":113},"Use only kerosene or No. 1 fuel oil, ensure qualified personnel follow regulations, extinguish all flames and allow the heater to cool before fueling, and inspect fuel lines for leaks before returning to service.",{"name":119,"@type":110,"acceptedAnswer":120},"What safety risk related to carbon monoxide is described?",{"text":121,"@type":113},"Carbon monoxide poisoning may lead to death, with early symptoms resembling the flu such as headaches, dizziness, and/or nausea; the manual instructs users to get fresh air immediately and have the heater serviced.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},646008,1792876117,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":39,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":26,"preview_page_count":4},962090893776,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","| Operating Instructions & Parts Manual |  |  |  | 2E510D, 2E511D, 3E218D, and 3E219C |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.\u003Cbr>Dayton® Portable Oil-Fired Heaters |  |  |  |  |  |  |  |  |  |\n| Description\u003Cbr>The Dayton models 2E510D, 2E511D, 3E218D, and 3E219C heaters are 30,000 to 150,000 Btu/Hr heaters. These heaters use Kerosene \\#1 fuel oil for combustion and electricity to run the motor. They are primarily intended for indoor and outdoor temporary heating of buildings under construction, alteration, or repair. They may be used in agricultural, industrial, and commercial environments. |  |  |  |  |  |  |  | Unpacking\u003Cbr>1. Remove all packing items supplied with heater for shipment.\u003Cbr>2. Remove all items from carton.\u003Cbr>3. Check heater for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater. |  |\n| \u003Cbr>Figure 1 – Models 2E510D and 2E511D |  |  | |  |  | \u003Cbr>Figure 2 – Models 3E218D and 3E219C |  |  |  |\n| GENERAL SPECIFICATIONS |  |  |  |  |  |  |  |  |  |\n| Model | Output Rating Btu | Fuel | Fuel Tank Capacity Fuel Consumption\u003Cbr>(U.S. Gallons) (U.S. Gallons/Hr.) |  |  |  |  |  | Motor RPM |\n| 2E510D | 35,000 | Kerosene or No. 1 | fuel oil |  | 3.0 |  | 0.3 |  | 1725 |\n| 2E511D | 55,000 | Kerosene or No. 1 | fuel oil |  | 5.0 |  | 0.4 |  | 1725 |\n| 3E218D | 110,000 | Kerosene or No. 1 | fuel oil |  | 9.0 |  | 0.8 |  | 3450 |\n| 3E219C | 150,000 | Kerosene or No. 1 | fuel oil 1 |  | 3.5 |  | 1.1 |  | 3450 |\n| Model | Hot Air\u003Cbr>Output (CFM) | Air Pump Pressure (PSI) | Shipping\u003Cbr>(Pounds) |  | Weight |  | Heater Weight\u003Cbr>(Pounds - without fuel) |  | Spark Plug Gap (Inches) |\n| 2E510D | 165 | 3.0 | 38 |  |  |  | 35 |  | .055 |\n| 2E511D | 175 | 3.4 | 39 |  |  |  | 36 |  | .075 |\n| 3E218D | 490 | 4.5 | 65 |  |  |  | 55 |  | .075 |\n| 3E219C | 500 | 5.0 | 65 |  |  |  | 55 |  | .075 |\n\nForm 5S1792  \nVersion B-For Reduction G016 .J  \n© 1995 W.W. Grainger, Inc.  \n®  \nPrinted in U.S.A.  \n03430  \n0895/206/VCPVP  \nDayton Operating Instructions and Parts Manual  \nDayton® Portable Oil-Fired Heaters  \nELECTRICAL SPECIFICATIONS  \nAmperage  \nModel Electrical Input (during normal run)  \n2E510D  \n2E511D 3E218D  \n3E219C  \n120 Volt/60 Hertz  \n120 Volt/60 Hertz  \n120 Volt/60 Hertz  \n120 Volt/60 Hertz  \n2.0  \n2.0  \n4.5  \n4.5  \nUpper Shell  \nProduct Identification Hot Air  \nOutlet  \nHandle  \nLower Shell  \nFuel  \nTank  \nFan Guard  \nAir Filter End Cover  \nFuel Cap  \nSide Cover  \nFigure 3 – Models 2E510D and 2E511D  \nFlame-Out Control Power Cord Reset Button  \nHot Air Outlet  \nFuel Cap  \nUpper Shell  \nFigure 4 – Models 3E218D and 3E219C  \nFlame-Out Control Reset Button  \nFan Guard  \nFuel  \nTank  \nPower Cord  \nLower Shell  \nSide Cover  \n101421  \nModels 2E510D, 2E511D, 3E218D, and 3E219C  \nGeneral Safety Information  \nMake certain you read and understand all warnings. Keep these instructions for reference. They are your guide to safe and proper operation of this heater. Safety information appears throughout these instructions. Pay close attention to them. Below are definitions for the safety information listed throughout this manual.  \nUnder this heading, installation, operat  \ning and maintenance procedures or practices will be found that, if not carefully followed, WILL result in IMMEDIATE serious personal injury or death.  \nUnder this heading, installation, operating, and maintenance procedures or practices will be found that, if not carefully followed, COULD result in severe personal injury or death.  \nUnder this heading, installation, operating, and maintenance procedures or practices will be found that, if not carefully followed, COU","cbCaidyq6F1nZLBp","https://ap.wps.com/l/cbCaidyq6F1nZLBp","pdf",706750,24,"English","# General Specifications\n## Models and Output Ratings\n## Fuel, Tank Capacity, Consumption, and Motor RPM\n## Hot Air Output, Air Pump Pressure, and Weights\n# Electrical Specifications\n## Electrical Input and Amperage\n# General Safety Information\n## Safety Warning Definitions\n## Carbon Monoxide Poisoning Hazards\n## Fueling Requirements","[{\"question\":\"What is the intended use of the Dayton portable oil-fired heaters in this manual?\",\"answer\":\"The heaters are primarily intended for indoor and outdoor temporary heating of buildings under construction, alteration, or repair.\"},{\"question\":\"What fueling rules does the manual emphasize?\",\"answer\":\"Use only kerosene or No. 1 fuel oil, ensure qualified personnel follow regulations, extinguish all flames and allow the heater to cool before fueling, and inspect fuel lines for leaks before returning to service.\"},{\"question\":\"What safety risk related to carbon monoxide is described?\",\"answer\":\"Carbon monoxide poisoning may lead to death, with early symptoms resembling the flu such as headaches, dizziness, and/or nausea; the manual instructs users to get fresh air immediately and have the heater serviced.\"}]","Dayton Portable Oil-Fired Heaters - Operating Instructions and Parts Manual - Models 2E510D, 2E511D, 3E218D, and 3E219C | PDF",1792745656]