[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-652366-105":59,"doc-detail-652366-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","dayton-motor-guide-popular-hvac-motors","Dayton Motor Guide - Popular HVAC Motors","","Dayton motor guide compiling popular HVAC motor models and specifications, organized by base type and electrical configuration. Tables list horsepower, frame, voltage ranges, RPM, rotation, overload protection type, required capacitor/shaft data, and Dayton item numbers. Coverage includes cradle base single phase split-phase and capacitor-start blower/fan motors, rigid base general-purpose units, direct drive shaded-pole/PSC blower motors, condenser fan motors, and three-phase condenser fan motors. Also includes EPACT efficient motors with warranty notes and efficiency listings.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/dayton-motor-guide-popular-hvac-motors/652366/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/dayton-motor-guide-popular-hvac-motors/652366.png","ImageObject",300,407,{"name":92,"@type":93},"Kyle","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-28","2026-10-24",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What information is provided for each Dayton HVAC motor model in the guide?","Question",{"text":112,"@type":113},"Each entry lists horsepower, frame, voltage, RPM, rotation, overload/protection construction notes, capacitor requirement where applicable, shaft dimensions, and the Dayton item number (plus short notes).","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Which motor categories are included in the “Popular HVAC Motors—Dayton” section?",{"text":117,"@type":113},"The guide covers cradle base split-phase and capacitor-start fan/blower motors, rigid base capacitor-start general-purpose motors, direct drive blower shaded-pole and PSC motors, condenser fan PSC motors, residential direct drive blower PSC models, double-shaft PSC OAO units, and condenser fan three-phase motors.",{"name":119,"@type":110,"acceptedAnswer":120},"What does the guide say about Dayton EPACT efficient motors?",{"text":121,"@type":113},"It specifies that Dayton EPACT motors from the -140 frame through the 284T frame have a 3-year warranty, and it provides tables with horsepower, frame, voltage, RPM, construction, efficiency, and item numbers.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},652366,1793016483,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":34,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144},3985741905716,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","[http://waterheatertimer.org/Color-codewire2.html\\#motor](http://waterheatertimer.org/Color-codewire2.html#motor)  \nPopular HVAC Motors—Dayton  \n|  | HP | Frame | Volts | RPM | Rot. | Cap. Req’d | Shaft Lng. (In.) | Shaft Dia. (In.) | Item No. | Notes** |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n\nCradle Base, Single Phase/Split Phase, Fan and Blower Motors, Open Drip-Proof  \n\n| 1/4 | 48 | 115 | 1725 | CW/CCW | no | 1 1/2 | 1/2* | 3K771 | Auto O/L, SB |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| 1/3 | 48 | 115 | 1725 | CW/CCW | no | 1 1/2 | 1/2* | 6K778 | Auto O/L SB |\n| 1/2 | 48 | 115 | 1725 | CW/CCW | no | 1 1/2 | 1/2* | 3K772 | Auto O/L SB |\n| 1/4 | 48 | 115/208-230 | 1725 | CW/CCW | no | 1 1/2 | 1/2* | 3ZP92 | Auto O/L, BB |\n| 1/3 | 48 | 115/208-230 | 1725 | CW/CCW | no | 1 1/2 | 1/2* | 3LY10 | Auto O/L, BB |\n| 1/2 | 48 | 115/208-230 | 1725 | CW/CCW | no | 1 1/2 | 1/2* | 3LY11 | Auto O/L, BB |\n\n*Motors in this section with 1/2 inch shafts are supplied with 5/8 inch bushing adaptor  \nCradle Base, Single Phase/Capacitor Start, Fan and Blower Motors, Open Drip-Proof  \n\n| 1/4 | 48 | 115/230 | 1725 | CW/CCW | no | 1 1/2 | 1/2 | 6K438 | Auto O/L BB |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| 1/3 | 48 | 115/230 | 1725 | CW/CCW | no | 1 1/2 | 1/2 | 6K490 | Auto O/L BB |\n| 1/2 | 48 | 115/230 | 1725 | CW/CCW | no | 1 1/2 | 1/2 | 6K965 | Auto O/L BB |\n| 3/4 | 56 | 115/230 | 1725 | CW/CCW | no | 1 7/8 | 5/8 | 6K376 | Auto O/L BB |\n| 1 | 56 | 115/208-230 | 1725 | CW/CCW | no | 1 7/8 | 5/8 | 6K321 | Auto O/L BB |\n\nRigid Base, Single Phase/Capacitor Start, General Purpose, Open Drip-Proof  \n\n| 1/3 | 56 | 115/230 | 1725 | CW/CCW | no | 1 7/8 | 5/8 | 5K115 | Auto O/L BB |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| 1/2 | 56 | 115/230 | 1725 | CW/CCW | no | 1 7/8 | 5/8 | 5K116 | Auto O/L BB |\n| 3/4 | 56 | 115/230 | 1725 | CW/CCW | no | 1 7/8 | 5/8 | 5K117 | Auto O/L BB |\n| 1 | 56H | 115/230 | 1725 | CW/CCW | no | 1 7/8 | 5/8 | 6K148 | Auto O/L BB |\n\nDirect Drive Blower, Single Phase/Shaded Pole and Permanent Split Capacitor, Open Air Over (A.O. Smith)  \n\n| 1/8 | 42Y | 115 | 1050/1 | CW/CCW | no | 5 | 1/2 | 4KA21 | Auto O/L SP |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| 1/8 | 42Y | 208-230 | 1050/1 | CW/CCW | no | 5 | 1/2 | 4KA45 | Auto O/L SP |\n| 1/5 | 42Y | 115 | 1050/1 | CW/CCW | no | 5 | 1/2 | 4KA46 | Auto O/L SP |\n| 1/5 | 42Y | 115 | 1050/3 | CW/CCW | no | 5 | 1/2 | 4KA41 | Auto O/L SP |\n| 1/5 | 42Y | 208-230 | 1050/3 | CW/CCW | no | 5 | 1/2 | 4KA42 | Auto O/L SP |\n| 1/5 | 42Y | 115 | 1075/3 | CW/CCW | 2GE78 | 5 | 1/2 | 4KA43 | Auto O/L PSC |\n| 1/5 | 42Y | 230 | 1075/3 | CW/CCW | 2GE78 | 5 | 1/2 | 4KA44 | Auto O/L PSC |\n\nCondenser Fan All Angle, Totally Enclosed, Permanent Split Capacitor (PSC), Stud Mount  \n\n| 1/6 | 48 | 208-230 | 1075 | CW/CCW | 2GE74 | 6 | 1/2 | 4M261 | Auto O/L BB |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| 1/4 | 48 | 208-230 | 1075 | CW/CCW | 2GE76 | 6 | 1/2 | 4M205 | Auto O/L BB |\n| 1/3 | 48 | 208-230 | 1075 | CW/CCW | 2GE78 | 6 | 1/2 | 4M206 | Auto O/L BB |\n| 1/2 | 48 | 208-230 | 1075 | CW/CCW | 2GE78 | 6 | 1/2 | 4M207 | Auto O/L BB |\n| 3/4 | 48 | 208-230 | 1075 | CW/CCW | 2GE79 | 6 | 1/2 | 4M208 | Auto O/L BB |\n| 1/6 | 48 | 208-230 | 825 | CW/CCW | 2GE76 | 6 | 1/2 | 4M225 | Auto O/L SB |\n| 1/4 | 48 | 208-230 | 825 | CW/CCW | 2GE76 | 6 | 1/2 | 4M226 | Auto O/L SB |\n| 1/3 | 48 | 208-230 | 825 | CW/CCW | 2GE80 | 6 | 1/2 | 4M262 | Auto O/L BB |\n| 1/2 | 48 | 208-230 | 825 | CW/CCW | 2GE80 | 6 | 1/2 | 4M263 | Auto O/L SB |\n\nResidential Direct Drive Blower, Open Air Over, Single Phase PSC (Stud-Ring, Torsion Flex Kits available)  \n\n| 1/4 | 48 | 115 | 1075/3 | CW/CCW | 2GE76 | 4 | 1/2 | 4M096 | Auto O/L SB |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| 1/4 | 48 | 208-230 | 1075/3 | CW/CCW | 2GE76 | 4 | 1/2 | 4M097 | Auto O/L SB |\n| 1/3 | 48 | 115 | 1075/3 | CW/CCW | 2GE7","cbCaiepOXk1qgWSL","https://ap.wps.com/l/cbCaiepOXk1qgWSL","pdf",290094,"English","# Popular HVAC Motors—Dayton\n## Cradle Base: Single Phase / Split Phase, Open Drip-Proof\n## Cradle Base: Single Phase / Capacitor Start, Open Drip-Proof\n## Rigid Base: Single Phase / Capacitor Start, General Purpose, Open Drip-Proof\n## Direct Drive Blower: Single Phase/Shaded Pole & Permanent Split Capacitor\n## Condenser Fan: All Angle, Totally Enclosed, Permanent Split Capacitor\n## Residential Direct Drive Blower: Single Phase PSC\n## Double Shaft Single Phase / PSC OAO (A.O. Smith)\n## Condenser Fan: Three Phase\n# EPACT Efficient Motors—Dayton","[{\"question\":\"What information is provided for each Dayton HVAC motor model in the guide?\",\"answer\":\"Each entry lists horsepower, frame, voltage, RPM, rotation, overload/protection construction notes, capacitor requirement where applicable, shaft dimensions, and the Dayton item number (plus short notes).\"},{\"question\":\"Which motor categories are included in the “Popular HVAC Motors—Dayton” section?\",\"answer\":\"The guide covers cradle base split-phase and capacitor-start fan/blower motors, rigid base capacitor-start general-purpose motors, direct drive blower shaded-pole and PSC motors, condenser fan PSC motors, residential direct drive blower PSC models, double-shaft PSC OAO units, and condenser fan three-phase motors.\"},{\"question\":\"What does the guide say about Dayton EPACT efficient motors?\",\"answer\":\"It specifies that Dayton EPACT motors from the -140 frame through the 284T frame have a 3-year warranty, and it provides tables with horsepower, frame, voltage, RPM, construction, efficiency, and item numbers.\"}]","Dayton Motor Guide - Popular HVAC Motors | PDF",1792880006,18]