[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-646010-105":59,"doc-detail-646010-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","dayton-high-intensity-heaters-installation-operation-maintenance-and-parts-manual","Dayton® High-Intensity Heaters - Installation, Operation, Maintenance and Parts Manual","","Installation, operation, and maintenance instructions for Dayton high-intensity infrared heaters, covering safety requirements, installation planning, and ongoing service responsibilities. Describes how the heaters generate infrared radiation by igniting a gas-air mixture on a heated ceramic refractory, along with typical workplace applications and clearance considerations. Includes safety symbols and hazard warnings, installation-related requirements such as ventilation and gas/electrical supply, operational guidance, troubleshooting, heater assembly components, parts listing, and a limited warranty for specified models.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/dayton-high-intensity-heaters-installation-operation-maintenance-and-parts-manual/646010/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/dayton-high-intensity-heaters-installation-operation-maintenance-and-parts-manual/646010.png","ImageObject",300,407,{"name":92,"@type":93},"hdkawk","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-13","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",12,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What is the required installation and service qualification for these heaters?","Question",{"text":113,"@type":114},"They must be installed and serviced only by trained gas installation and service personnel. Improper installation or maintenance can result in property damage, serious injury, or death.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How do these Dayton high-intensity heaters produce heat?",{"text":118,"@type":114},"A gas-air mixture is passed through a perforated ceramic refractory and ignited on the refractory surface, heating the ceramic to incandescence and generating infrared radiation.",{"name":120,"@type":111,"acceptedAnswer":121},"What should be done if gas is smelled?",{"text":122,"@type":114},"Do not try to light appliances, do not touch electrical switches, do not use a phone in the building, call the gas supplier from a neighbor’s phone, follow instructions, and if unable to reach the supplier, call the fire department.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},646010,1792789731,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":26,"preview_page_count":4},3985747859855,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","Installation, Operation, Maintenance and Parts Manual  \n3E132 thru 3E134, 3E460 thru 3E462, 5VD57 thru 5VD66, 3VH34 thru 3VH37  \nPlease read and save these instructions. This heater must be installed and serviced by trained gas installation and service personnel only! Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain these instructions for future reference.  \nDayton® High-Intensity Heaters  \nDescription  \nDayton high-intensity heaters become highly efficient generators of infrared radiation by heating a ceramic refractory material to incandescence. The principal operation is to pass a gas-air mixture through a perforated ceramic refractory, and ignite it on the refractory surface. This causes the ceramic material to be heated to approximately 1780°F and generate large amounts of infrared radiation that may be directed anywhere heat is desired. Infrared radiation heats people and objects it strikes and not the intervening air. Included is a direct spark ignition system, manifold pressure tap, porous ceramic grids, a polished aluminum reflector and a chain set for hanging the heater. Typical applications are loading docks, warehouses, service garages, factories, aircraft hangars, etc.  \n\n|  ! WARNING |  |  |  |  ! WARNING |\n| --- | --- | --- | --- | --- |\n| |  | Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read and understand the installation, |  | In locations used for the storage of combustible materials, signs must be posted to specify the maximum permissible stacking height to maintain\u003Cbr>the required clearances from the heater to the combustibles. Signs must either be posted adjacent to the heater thermostats or in the absence of such thermostats, in a conspicuous location.\u003Cbr>|\n| operating and maintenance instructions thoroughly before installing or servicing this equipment.\u003Cbr>This heater must be installed and serviced by trained gas installation and service personnel only. Failure to comply could result in personal injury, asphyxiation, death, fire and/or property damage. |  |  |  |  |\n|  |  |  | For Your Safety If you smell gas:\u003Cbr>• Do not try to light any appliance.\u003Cbr>• Do not touch any electrical switch.\u003Cbr>• Do not use any phone in your building.\u003Cbr>• Immediately call your gas supplier from a neighbor’s phone.\u003Cbr>• Follow the gas supplier’s instructions.\u003Cbr>• If you cannot reach your gas supplier, call the fire department.\u003Cbr>Keep these instructions for future reference. |  |\n|  |  |  |  |  |\n| \u003Cbr> ! WARNING\u003Cbr>Not for residential use!\u003Cbr>This heater is not approved in any residential application. This includes (but is not limited to) the home, living\u003Cbr>quarters, attached garages, etc. Installation in residential indoor spaces may result in property damage, serious injury or death.\u003Cbr>|  |  |  |  |\n|  |  |  |  |  |\n\nForm 5S4078 Printed in U. S.A.  \n03460  \n1006/281/VCPVP  \n®  \nE  \nN  \nG  \nL  \nI  \nS  \nH  \nE  \nN  \nG  \nL  \nI  \nS  \nH  \nDayton® High Intensity Heaters  \n1.0 Safety .................................................................... 3  \nSafety Symbols ........................................................ 3  \nApplications .......................................................... 3  \nClearance to Combustibles ............................................... 4  \nStandards, Certifications and Government Regulations .......................... 6  \nHeater Dimensions ..................................................... 7  \nSafety Signs and Labels .................................................. 8  \n2.0 Installation ............................................................... 9  \nDesign .............................................................. 9  \nHeater Placement ...................................................... 10  ","cbCaisx6GjhOanCE","https://ap.wps.com/l/cbCaisx6GjhOanCE","pdf",3717599,24,"English","# 1.0 Safety\n## Safety Symbols\n## Applications\n## Clearance to Combustibles\n## Standards, Certifications and Government Regulations\n## Heater Dimensions\n## Safety Signs and Labels\n# 2.0 Installation\n## Design\n## Heater Placement\n## Heater Mounting\n## Ventilation\n## Gas Supply\n## Electrical\n# 3.0 Operation\n# 4.0 Maintenance\n## Troubleshooting Guide\n## Heater Assembly Components\n## Parts Listing\n# 5.0 Limited Warranty","[{\"question\":\"What is the required installation and service qualification for these heaters?\",\"answer\":\"They must be installed and serviced only by trained gas installation and service personnel. Improper installation or maintenance can result in property damage, serious injury, or death.\"},{\"question\":\"How do these Dayton high-intensity heaters produce heat?\",\"answer\":\"A gas-air mixture is passed through a perforated ceramic refractory and ignited on the refractory surface, heating the ceramic to incandescence and generating infrared radiation.\"},{\"question\":\"What should be done if gas is smelled?\",\"answer\":\"Do not try to light appliances, do not touch electrical switches, do not use a phone in the building, call the gas supplier from a neighbor’s phone, follow instructions, and if unable to reach the supplier, call the fire department.\"}]","Dayton® High-Intensity Heaters - Installation, Operation, Maintenance and Parts Manual | PDF",1792745660]