[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-646011-105":59,"doc-detail-646011-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","dayton-high-intensity-heaters-installation-operation-maintenance-and-parts-manual-646011","Dayton - High-Intensity Heaters - Installation, Operation, Maintenance and Parts Manual","","Instruction manual for Dayton high-intensity infrared heaters, covering safe installation, operation, maintenance, and parts support for specified heater model ranges. Explains how the heaters generate infrared radiation by igniting a gas-air mixture on a perforated ceramic refractory, highlights warnings including trained gas personnel requirements, combustible-clearance posting, and non-residential limitations. Provides structured sections for safety symbols, clearance guidance, installation design and placement, ventilation, gas supply, electrical requirements, operation, maintenance, troubleshooting, component identification, parts listing, and limited warranty.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/dayton-high-intensity-heaters-installation-operation-maintenance-and-parts-manual-646011/646011/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/dayton-high-intensity-heaters-installation-operation-maintenance-and-parts-manual-646011/646011.png","ImageObject",300,407,{"name":92,"@type":93},"mieayamfan","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-06","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":44},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Who is allowed to install and service these heaters?","Question",{"text":112,"@type":113},"Only trained, qualified gas installation and service personnel may install or service the equipment.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What should be followed before installing or servicing the heater?",{"text":117,"@type":113},"Read and understand the installation, operating, and maintenance instructions thoroughly, and observe all safety information to prevent personal injury and/or property damage.",{"name":119,"@type":110,"acceptedAnswer":120},"Are these heaters approved for residential use?",{"text":121,"@type":113},"No. The manual states the heater is not for residential use and is not approved for residential applications, including homes and living quarters.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},646011,1792789731,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":44,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":26,"preview_page_count":4},962090893677,"https://ap-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","Installation, Operation, Maintenance and Parts Manual  \n3E132E thru 3E134E, 3E460C thru 3E462C, 5VD57 thru 5VD66, 3VH34 thru 3VH37  \nPlease read and save these instructions. This heater must be installed and serviced by trained gas installation and service personnel only! Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain these instructions for future reference.  \nDayton® High-Intensity Heaters  \nDescription  \nDayton high-intensity heaters become highly efficient generators of infrared radiation by heating a ceramic refractory material to incandescence. The principal operation is to pass a gas-air mixture through a perforated ceramic refractory, and ignite it on the refractory surface. This causes the ceramic material to be heated to approximately 1780°F and generate large amounts of infrared radiation that may be directed anywhere heat is desired. Infrared radiation heats people and objects it strikes and not the intervening air. Included is a direct spark ignition system, manifold pressure tap, porous ceramic grids, a polished aluminum reflector and a chain set for hanging the heater. Typical applications are loading docks, warehouses, service garages, factories, aircraft hangars, etc.  \n\n|  ! WARNING |  |  |  ! WARNING |\n| --- | --- | --- | --- |\n| Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read and understand the installation,\u003Cbr>operating and maintenance instructions thoroughly before installing or servicing this equipment.\u003Cbr>This heater must be installed and serviced by trained gas installation and service personnel only. Failure to comply could result in personal injury, asphyxiation, death, fire and/or property damage.\u003Cbr>|  |  | In locations used for the storage of combustible materials, signs must be posted to specify the maximum permissible stacking height to maintain\u003Cbr>the required clearances from the heater to the combustibles. Signs must either be posted adjacent to the heater thermostats or in the absence of such thermostats, in a conspicuous location.\u003Cbr>|\n|  |  | For Your Safety If you smell gas:\u003Cbr>• Do not try to light any appliance.\u003Cbr>• Do not touch any electrical switch.\u003Cbr>• Do not use any phone in your building.\u003Cbr>• Immediately call your gas supplier from a neighbor’s phone.\u003Cbr>• Follow the gas supplier’s instructions.\u003Cbr>• If you cannot reach your gas supplier, call the fire department.\u003Cbr>Keep these instructions for future reference. |  |\n|  |  |  |  |\n| \u003Cbr> ! WARNING\u003Cbr>Not for residential use!\u003Cbr>This heater is not approved in any residential application. This includes (but is not limited to) the home, living\u003Cbr>quarters, attached garages, etc. Installation in residential indoor spaces may result in property damage, serious injury or death.\u003Cbr>|  |  |  |\n|  |  |  |  |\n\nForm 5S4078 Printed in U. S.A.  \n03460  \n1006/281/VCPVP  \n02/2016  \nE  \nN  \nG  \nL  \nI  \nS  \nH  \nE  \nN  \nG  \nL  \nI  \nS  \nH  \nDayton® High Intensity Heaters  \n1.0 Safety .................................................................... 3  \nSafety Symbols ........................................................ 3  \nApplications .......................................................... 3  \nClearance to Combustibles ............................................... 4  \nStandards, Certifications and Government Regulations .......................... 6  \nHeater Dimensions ..................................................... 7  \nSafety Signs and Labels .................................................. 8  \n2.0 Installation ............................................................... 9  \nDesign .............................................................. 9  \nHeater Placement ...................................................... 10  \nHeater Mounting ......","cbCaidi70Qo9socf","https://ap.wps.com/l/cbCaidi70Qo9socf","pdf",2861881,24,"English","# 1.0 Safety\n## Safety Symbols\n## Applications\n## Clearance to Combustibles\n## Standards, Certifications and Government Regulations\n## Heater Dimensions\n## Safety Signs and Labels\n# 2.0 Installation\n## Design\n## Heater Placement\n## Heater Mounting\n## Ventilation\n## Gas Supply\n## Electrical Requirements and Diagrams\n# 3.0 Operation\n# 4.0 Maintenance\n## Troubleshooting Guide\n## Heater Assembly Components\n## Parts Listing\n# 5.0 Limited Warranty","[{\"question\":\"Who is allowed to install and service these heaters?\",\"answer\":\"Only trained, qualified gas installation and service personnel may install or service the equipment.\"},{\"question\":\"What should be followed before installing or servicing the heater?\",\"answer\":\"Read and understand the installation, operating, and maintenance instructions thoroughly, and observe all safety information to prevent personal injury and/or property damage.\"},{\"question\":\"Are these heaters approved for residential use?\",\"answer\":\"No. The manual states the heater is not for residential use and is not approved for residential applications, including homes and living quarters.\"}]","Dayton - High-Intensity Heaters - Installation, Operation, Maintenance and Parts Manual | PDF",1792745662]