[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-646014-105":59,"doc-detail-646014-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","dayton-electric-utility-heaters-installation-and-safety-instructions","Dayton Electric Utility Heaters - Installation and Safety Instructions","","Dayton electric utility heaters deliver 6,396 to 17,065 BTU per hour with adjustable wiring configurations, supporting both horizontal and vertical air flow, a built-in thermostat, and a high-limit thermal cutout. The manual provides general safety guidance covering wiring requirements, grounding, fuse protection, mounting and clearance distances, and prohibitions for hazardous and corrosive environments. It also explains locating the heater for unobstructed circulation and describes bracket mounting and hanging procedures for the 3UG73D and 3UG74D models.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/dayton-electric-utility-heaters-installation-and-safety-instructions/646014/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/dayton-electric-utility-heaters-installation-and-safety-instructions/646014.png","ImageObject",300,407,{"name":92,"@type":93},"CatatanPagi","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-12","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":52},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What safety precautions must be followed during installation and servicing?","Question",{"text":112,"@type":113},"Read and understand the installation and operation instructions and observe all safety information. Disconnect all electrical power and lock the main service box before installing, inspection, cleaning, or servicing to prevent serious electrical shock.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What wiring and grounding requirements are specified?",{"text":117,"@type":113},"Use only copper wire rated at least 60°C. All wiring must conform to national and local electrical codes in the United States, and the heater must be grounded. The heater circuit must be protected with proper fuses.",{"name":119,"@type":110,"acceptedAnswer":120},"Where can these heaters not be used?",{"text":121,"@type":113},"These heaters are not suitable for hazardous locations or for corrosive atmospheres such as marine, greenhouses, or chemical storage areas. Do not use where gasoline, paint, or flammable liquids are used or stored.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},646014,1792789731,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":52,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":34,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144,"preview_page_count":4},962090894170,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","Please read and save these instructions.Read carefully before attempting to assemble,install,operate or maintain the productdescribed.Protect yourself and othersby observing all safety information.Failure to comply with instructions could result inpersonal injury and/or property damage!Retain instructions for future reference.  \n# Dayton°ElectricUtility Heaters\n\n## Description\n\nDayton electric utility heaters are designed to meet a variety of heatingrequirements by switching a few wires located in the base of the unit.Heatoutput ranges from 6,396 to 17,065 BTU per hour.Features horizontal andvertical flow (horizontal air throw approximately 18 ft.),built-in thermostat,and high limit thermal cutout.  \n## Specifications\n\nAmpsBTU/hour3UG73D(Can be operated at 208VSee Table 1 for ratings)240V 208VCFMRise 240V208V*5000 W@240/208V-1-6020.918.027060°F 17,06512,7994165W@240/208V-1-6017.415.027014,21510,6593332 W@240/208V-1-6013.912.027011,3658,5332500 W@240/208V-1-6010.49.02708,5336,393*5000 W@208V-1-6024.027060°F17,0654165W@208V-1-6020.0  27014,2153332 W@208V-1-6011,3652500 W@208V-1-608,533  \n3UG74D  \n(*)Heater is shipped from factory wired for these wattages.Heater can be fieldadjusted to the other wattages(Refer to\"Adjusting the Heat Output\"on page 4).  \nNote:Min.clearance to ceilingwhen not using mounting bracketsis 15/8 in.  \nTO FIOOR6 ft.  \nMAXIMIUM MOUNTING HEIGHT FOR:Vertical air delivery unit=11 ft.Horizontal air delivery unit=8ft.SIDE VIEW  \nFRONT VIEW  \nFigure 2-Dimensions  \nE154218  \nFigure 1  \nUnpacking  \nRemove the heater from box and inspectfor any damage.If it appears to bedamaged,immediately return.  \nCheck the contents of the box to makesure it contains one heating unit andone mounting bracket.  \n## General Safety Information\n\nRead and understand  \nAWARNING  \ninstallation and  \noperation instructions and observe allsafety instructions.  \n1.Use only copper wire rated at least 60℃.  \n2.Heater air flow must be directed parallelto,or away from,adjacent walls.  \n3.Observe wall,floor,and ceiling clearancerequirements.  \n4.All wiring must conform to national andlocal electrical codes in the United Statesand the heater must be grounded as aprecaution against possible electricalshock.Heater circuit must be protectedwith proper fuses (See Table 1 page 4).  \nENGLiSH  \n## General Safety Information(Continued)\n\n5.The mounting structure and theanchoring hardware must be capable ofreliably supporting the weight of theheater and,if used,the mountingbracket.  \n6.All electrical power must bedisconnected and the main serviceboxmust be locked before installinginspection,cleaning or servicing theheater.This is a precaution to preventserious electrical shock.  \n7.This heater is not suitable for use inhazardous locations as defined by theNational Fire Protection Association(NFPA)in the United States.This heaterhas hot and arcing(sparking)partsinside.Do not use in areas wheregasoline,paint,or flammable liquids areused or stored.  \n8.This heater is not suitable for use incorrosive atmospheres such as marine,greenhouses or chemical storage areas.  \n9.This heater must be mounted at least 6feet off the floor.  \nImproper installation  \n▲ CAUTION  \nor failure to follow the  \n   \nprocedures outlined in this instruction  \nmanual can result in serious electrical  \nshock.  \n### LOCATING HEATER\n\nInstall heater out of traffic areasmaintaining clearances stated in Figure 2.The direction of air flow should not berestricted (ie:by columns or machinery)and the air flow should wipe exposedwalls,rather than blowing directly atthem.When more than one heater is usedin an area,the heaters should bearranged so that the air discharge of eachheater supports the air flow of the othersto provide best circulation of warm air,asindicated in Figure 3.  \n## Dayton°Electric Utility Heaters\n\nFigure 3  \n### InstallationMOUNTING THE BRACKET\n\nRefer to Figures 4a and 4b.  \n1.Locate a stud in the ceiling joist.  \n2.Remove the mounting bracket from theheating unit by loosening ","cbCaipUo3UbkV1aI","https://ap.wps.com/l/cbCaipUo3UbkV1aI","pdf",837921,"English","# Dayton Electric Utility Heaters\n## Description\n## Specifications\n## Unpacking\n## General Safety Information\n## Locating Heater\n## Installation\n## Mounting the Bracket\n## Hanging the Heater\n## Models 3UG73D and 3UG74D\n## Connecting the Power","[{\"question\":\"What safety precautions must be followed during installation and servicing?\",\"answer\":\"Read and understand the installation and operation instructions and observe all safety information. Disconnect all electrical power and lock the main service box before installing, inspection, cleaning, or servicing to prevent serious electrical shock.\"},{\"question\":\"What wiring and grounding requirements are specified?\",\"answer\":\"Use only copper wire rated at least 60°C. All wiring must conform to national and local electrical codes in the United States, and the heater must be grounded. The heater circuit must be protected with proper fuses.\"},{\"question\":\"Where can these heaters not be used?\",\"answer\":\"These heaters are not suitable for hazardous locations or for corrosive atmospheres such as marine, greenhouses, or chemical storage areas. Do not use where gasoline, paint, or flammable liquids are used or stored.\"}]","Dayton Electric Utility Heaters - Installation and Safety Instructions | PDF",1792745671,18]