[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-641587-105":59,"doc-detail-641587-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","datex-ohmeda-s5tm-compact-anesthesia-monitor-technical-reference-manual","Datex-Ohmeda S/5TM Compact Anesthesia Monitor - Technical Reference Manual","","Technical reference manual for the GE Datex-Ohmeda S/5TM Compact Anesthesia Monitor and the S/5TM Compact Critical Care Monitor. Defines intended purposes for multiparameter monitoring across hemodynamic, respiratory, ventilatory, gastrointestinal/regional perfusion, BIS, Entropy, and neurophysiological status, including BIS-assisted monitoring of anesthetic effects. Covers key classifications and electromagnetic-related conformance references, manufacturer responsibility conditions, trademarks, availability notes, and service guide partitions for general and product-specific maintenance tasks.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/datex-ohmeda-s5tm-compact-anesthesia-monitor-technical-reference-manual/641587/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/datex-ohmeda-s5tm-compact-anesthesia-monitor-technical-reference-manual/641587.png","ImageObject",300,407,{"name":92,"@type":93},"Aria Callaghan","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-07","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":29},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the intended purpose of the Datex-Ohmeda S/5 Compact Anesthesia Monitor with L-CANE06 or L-CANE06A software?","Question",{"text":112,"@type":113},"It is intended for multiparameter patient monitoring with optional patient care documentation. It monitors hemodynamic, respiratory, ventilatory, gastrointestinal/regional perfusion, BIS, Entropy, and neurophysiological status for all hospital patients.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How does BIS support clinical monitoring with the S/5 Compact monitors?",{"text":117,"@type":113},"When using BIS, the monitors support monitoring the state of the brain by acquiring and processing electroencephalograph signals. The BIS function may aid in monitoring effects of certain anesthetic agents.",{"name":119,"@type":110,"acceptedAnswer":120},"What conditions must be met for the manufacturer to be responsible for safety, reliability, and performance?",{"text":121,"@type":113},"Responsibility applies only if assembly/modifications/servicing and repairs are performed by GE-authorized personnel, the monitor room electrical installation meets requirements, and the equipment is used according to the User's Guide and maintained per the Technical Reference Manual.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},641587,1792910161,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":29,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":4},962084926284,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","GE Healthcare  \nDatex-Ohmeda S/5TM Compact Anesthesia Monitor Datex-Ohmeda S/5TM Compact Critical Care Monitor Technical Reference Manual  \nConformity according to the Council Directive 93/42/EEC concerning Medical Devices  \nCAUTION: U.S. Federal law restricts this device to sale by or on the order of a licensed medical practitioner. Outside the USA, check local laws for any restriction that may apply.  \nAll specifications subject to change without notice.  \nOrder code M1065281 1st edition  \nJune 2, 2008  \nGE Healthcare Finland Oy Helsinki, Finland  \nP. O. Box 900  \nFI-00031 GE, FINLAND Tel: +358 10 39411  \nFax: +358 9 1463310  \n[www.gehealthcare.com](www.gehealthcare.com)  \nCopyright © 2008 General Electric Company. All rights reserved.  \nDatex-Ohmeda Inc.  \nP.O. Box 7550  \nMadison, WI 53707-7550, USA Tel: +1 608 221 1551  \nFax: +1 608 222 9147  \nIntended purpose (Indications for use)  \nThe Datex-Ohmeda S/5 Compact Anesthesia Monitor with L-CANE06 or L-CANE06A software is intended for multiparameter patient monitoring with optional patient care documentation.  \nThe S/5 Compact Anesthesia Monitor with L-CANE06 or L-CANE06A software is indicated for monitoring of hemodynamic (including arrhythmia and ST-segment analysis), respiratory, ventilatory, gastrointestinal/regional perfusion, Bispectral index (BIS), Entropy (State Entropy and Response Entropy) and neurophysiological status of all hospital patients.  \nThe S/5 Compact Anesthesia Monitor with L-CANE06 and L-CANE06A software when using BIS is for monitoring the state of the brain by data acquisition and processing of electroencephalograph signals and may be used as an aid in monitoring the effects of certain anesthetic agents.  \nThe S/5 Compact Anesthesia Monitor with L-CANE06 or L-CANE06A software is also indicated for documenting patient care related information.  \nThe S/5 Compact Anesthesia Monitor with L-CANE06 or L-CANE06A software is indicated for use by qualified medical personnel only.  \nThe Datex-Ohmeda S/5 Compact Critical Care Monitor with L-CICU06 or L-CICU06A software is intended for multiparameter patient monitoring.  \nThe S/5 Compact Critical Care Monitor with L-CICU06 and L-CICU06A software is indicated for monitoring of hemodynamic (including arrhythmia and ST-segment analysis), respiratory, ventilatory, gastrointestinal/regional perfusion, Bispectral index (BIS) and neurophysiological status of all hospital patients.  \nThe S/5 Compact Critical Care Monitor with L-CICU06 and L-CICU06A software when using BIS is for monitoring the state of the brain by data acquisition and processing of electroencephalograph signals and may be used as an aid in monitoring the effects of certain anesthetic agents.  \nThe S/5 Compact Critical Care Monitor with L-CICU06 and L-CICU06A software is indicated for use by qualified medical personnel only.  \nClassifications  \nIn accordance with IEC 60601-1  \nClass I and internally powered equipment – the type of protection against electric shock.  \nType BF or CF equipment. The degree of protection against electric shock is indicated by a symbol on each parameter module.  \nEquipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide.  \nContinuous operation according to the mode of operation.  \nIn accordance with IEC 60529  \nIn accordance with EU Medical Device Directive  \nThe Datex-Ohmeda S/5 Compact Anesthesia Monitor is classified as IIb.  \nThe Datex-Ohmeda S/5 Compact Critical Care Monitor is classified as IIb.  \nIn accordance with CISPR 11:  \nGroup 1, Class A  \n• Group 1 contains all ISM (industrial, scientific and medical) equipment in which there is intentionally generated and/or used conductively coupled radio-frequency energy which is necessary for the internal functioning of the equipment itself.  \nResponsibility of the manufacturer  \nGE Healthcare Finland Oy (GE) is responsible for the effects on safety, reliability and performance of the equipment only if:  \n• assem","cbCaiq4kTnJejywl","https://ap.wps.com/l/cbCaiq4kTnJejywl","pdf",4827642,335,"English","# Intended purpose (Indications for use)\n# Classifications\n# Responsibility of the manufacturer\n# Trademarks\n# Product availability\n# Part I, General Service Guide\n## Introduction, System description, Installation, Interfacing, Functional check, General troubleshooting\n## Planned Maintenance Instructions\n# Part II, Product Service Guide\n## CAM, CCCM Service Menu\n## Display Unit for F-CM1, F-CMC1\n## Frame Unit for F-CM1, F-CMC1\n## Spare parts","[{\"question\":\"What is the intended purpose of the Datex-Ohmeda S/5 Compact Anesthesia Monitor with L-CANE06 or L-CANE06A software?\",\"answer\":\"It is intended for multiparameter patient monitoring with optional patient care documentation. It monitors hemodynamic, respiratory, ventilatory, gastrointestinal/regional perfusion, BIS, Entropy, and neurophysiological status for all hospital patients.\"},{\"question\":\"How does BIS support clinical monitoring with the S/5 Compact monitors?\",\"answer\":\"When using BIS, the monitors support monitoring the state of the brain by acquiring and processing electroencephalograph signals. The BIS function may aid in monitoring effects of certain anesthetic agents.\"},{\"question\":\"What conditions must be met for the manufacturer to be responsible for safety, reliability, and performance?\",\"answer\":\"Responsibility applies only if assembly/modifications/servicing and repairs are performed by GE-authorized personnel, the monitor room electrical installation meets requirements, and the equipment is used according to the User's Guide and maintained per the Technical Reference Manual.\"}]","Datex-Ohmeda S/5TM Compact Anesthesia Monitor - Technical Reference Manual | PDF",1792715049,844]