[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-289228-105":59,"doc-detail-289228-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","dat-negative-hemolytic-anemia-evaluation-versiti-enhanced-direct-antiglobulin-super-coombs-test","DAT Negative Hemolytic Anemia Evaluation - Versiti Enhanced Direct Antiglobulin (“super Coombs”) Test","","DAT Negative Hemolytic Anemia Evaluation by Versiti provides serological testing to detect C3, IgA and/or IgG on red blood cells when conventional direct antiglobulin testing is negative or inconclusive. A negative DAT occurs in about 5–10% of suspected hemolytic anemia cases, so the lab uses a more sensitive enhanced DAT (“super Coombs”) to confirm autoimmune hemolytic anemia and clarify cases with low IgG levels, eluted low-affinity antibodies, or IgA autoantibodies missed by standard monoclonal AHG testing.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/dat-negative-hemolytic-anemia-evaluation-versiti-enhanced-direct-antiglobulin-super-coombs-test/289228/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/dat-negative-hemolytic-anemia-evaluation-versiti-enhanced-direct-antiglobulin-super-coombs-test/289228.png","ImageObject",300,407,{"name":92,"@type":93},"Ivy","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-20","2026-09-17",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",15,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"When is the enhanced DAT (“super Coombs”) recommended?","Question",{"text":113,"@type":114},"It is used when a standard DAT is negative or inconclusive and investigation is needed for an immune-mediated cause of autoimmune hemolytic anemia.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"What situations can produce a negative standard DAT despite autoimmune hemolytic anemia?",{"text":118,"@type":114},"Examples include sensitized RBCs with IgG below detection, low-affinity IgG eluted during routine washing, or IgA autoantibodies missed by standard monoclonal AHG testing.",{"name":120,"@type":111,"acceptedAnswer":121},"What specimens and volumes are required for this test?",{"text":122,"@type":114},"Three 7 mL clot tubes (red top) and two 5 mL EDTA (lavender top) whole blood samples are required.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},289228,1789634785,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":14,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":130,"read_time":24,"preview_page_count":14,"preview_urls":144},549758252649,"https://ap-avatar.wpscdn.com/avatar/8000253669c5317157?_k=1778319167496531819","DAT Negative Hemolytic Anemia Evaluation  \nHemolytic Anemia is a serious condition that can be fatal. Versiti offers serological testing to identify the presence of C3, IgA and/or IgG molecules on the surface of the patient’s red blood cell when conventional direct antiglobulin tests are negative or inconclusive.  \nA negative Direct Antiglobulin Test (DAT) is seen in approximately 5-10% of patients presenting with signs and symptoms of hemolytic anemia.1,2 A well-performed standard DAT detects approximately 150-500 molecules of bound IgG per red cell.1,2 Our laboratory performs a more sensitive, enhanced DAT (“super Coombs”)3-5 in order to confirm a diagnosis of autoimmune hemolytic anemia inpatients whose samples have tested negative in a standard DAT for any of the following reasons:  \n• Patient RBCs are sensitized with small numbers of IgG molecules, below the level of detection of the standard DAT.  \n• Low-affinity IgG autoantibodies are eluted from RBCs during routine washing of the RBCs prior to the detection phase of the standard DAT.  \n• IgA autoantibodies not detected by a standard DAT that is performed using monoclonal AHG.5  \nIndications for testing:  \nTo aid in the investigation of an immune-mediated cause for autoimmune hemolytic anemia (AHIA) when the conventional DAT is negative or inconclusive. This test is not appropriate or may not further elucidate the mechanism of AIHA for patients with a positive DAT by routine methods. Please consult the Immunohematology Reference Lab prior to sending samples on patients with positive DAT.  \nTest method:  \nSerological. Typical evaluation workup includes:  \n• ABO and Rh  \n• Standard Direct Antiglobulin Tests (IgG and C3),  \n• Enhanced Direct Antiglobulin Test, including IgA Detection  \n• Elution (Routine and Enhanced)  \n• Antibody Detection Tests (Routine and Enhanced)  \n* Some additional tests may be necessary based upon results determined by the testing lab.  \nAssay sensitivity and limitations:  \nNegative results do not completely rule out the presence of immune-mediated hemolytic anemia. Positive test results alone are not diagnostic and must be evaluated in combination with clinical and other laboratory information to make a diagnosis.  \nSpecimen requirements:  \nThree 7 mL clot tubes (red top) and two 5 mL EDTA (lavender top) whole blood.  \nShipping requirements:  \nShip refrigerated. Insert specimens and the test requisition form into plastic bags and seal. Insert into a Styrofoam container; seal and place into a sturdy cardboard box and tape securely; ship by an overnight carrier. Ship the package in compliance with your overnight carrier guidelines. Please contact your carrier  \nfor current biohazard shipping regulations.  \nLabel with the following address:  \nVersiti Client Services Immunohematology Reference Laboratory 638 N. 18th Street  \nMilwaukee, WI 53233 800-245-3117, ext. 6250  \nRequired forms:  \nPlease complete all pages of the requisition form. Clinical history (including patient’s ethnicity, clinical diagnosis, family history and relevant laboratory findings) is necessary for optimal interpretation of the results and recommendations. Clinical and laboratory history can either be recorded on the requisition form  \nor clinical and laboratory reports can be submitted with the sample.  \nReferences:  \n1. Barcellini W, Zaninoni,A, Giannotta JA, Fattizzo B. New Insights in Autoimmune Hemolytic Anemia: From Pathogenesis to Therapy. J. Clin. Med. 2020, 9, 3859; doi:10 .3390/jcm9123859  \n2. Segel GB, Lichtman MA. Direct antiglobulin (“Coombs”) test-negative autoimmune hemolytic anemia: A review. Blood Cells, Molecules and Diseases 52 (2014) 152–160.  \n3. Fueger JT, Gottschall JL, Curtis BR, Johnson ST. DAT-negative immune hemolytic anemia – the role of enhanced techniques. Transfusion 2003;43(suppl. ):103A.  \n4. Karafin MS, Denomme GA, Schanen M, Gottschall JL. Clinical and reference lab characteristics of patients with suspected direct antiglobulin test (DAT)-negati","cbCailPm1EUrmLKo","https://ap.wps.com/l/cbCailPm1EUrmLKo","pdf",88792,"English","# Indications for testing\n# Test method\n## Serological evaluation workup\n# Assay sensitivity and limitations\n# Specimen requirements\n# Shipping requirements\n# Required forms","[{\"question\":\"When is the enhanced DAT (“super Coombs”) recommended?\",\"answer\":\"It is used when a standard DAT is negative or inconclusive and investigation is needed for an immune-mediated cause of autoimmune hemolytic anemia.\"},{\"question\":\"What situations can produce a negative standard DAT despite autoimmune hemolytic anemia?\",\"answer\":\"Examples include sensitized RBCs with IgG below detection, low-affinity IgG eluted during routine washing, or IgA autoantibodies missed by standard monoclonal AHG testing.\"},{\"question\":\"What specimens and volumes are required for this test?\",\"answer\":\"Three 7 mL clot tubes (red top) and two 5 mL EDTA (lavender top) whole blood samples are required.\"}]","DAT Negative Hemolytic Anemia Evaluation - Versiti Enhanced Direct Antiglobulin (“super Coombs”) Test | PDF",[145,149],{"page_no":8,"url":146,"width":147,"height":148},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/61bbebaa7ba341185b96153a85ced51e.webp",983,1272,{"page_no":14,"url":150,"width":151,"height":152},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/ef208a31c233f3691de48105e666348a.webp",982,1270]