[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-672614-105":59,"doc-detail-672614-en":129},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":122,"head_meta":124,"extra_data":126,"updated_unix":128},105,"en","d365pla-and-dnrw-intelligent-non-relay-photoelectric-duct-smoke-detectors-product-overview","D365PL(A) and DNRW Intelligent Non-relay Photoelectric Duct Smoke Detectors - Product Overview","","Fire•Lite D365PL(A) and DNRW intelligent non-relay photoelectric duct smoke detectors feature a pivoting housing that mounts to both square and rectangular duct footprints and supports installation on round or rectangular ducts. The NEMA-4 rated DNRW enclosure withstands falling dirt, rain, windblown dust, and hose-directed water. Designed for airflow speeds up to 4,000 ft/min, temperatures from -4°F to 158°F, and humidity 0–93% (non-condensing), they isolate the sensor head for maintenance and provide cover tamper trouble signals. Units support remote testing, require loop power only, and can be customized to local code.",{"@graph":69,"@context":121},[70,84,104],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/d365pla-and-dnrw-intelligent-non-relay-photoelectric-duct-smoke-detectors-product-overview/672614/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":98,"encodingFormat":97,"isAccessibleForFree":99,"interactionStatistic":100},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/d365pla-and-dnrw-intelligent-non-relay-photoelectric-duct-smoke-detectors-product-overview/672614.png","ImageObject",300,407,{"name":92,"@type":93},"Hazel","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-02",true,{"@type":101,"interactionType":102,"userInteractionCount":8},"InteractionCounter",{"@type":103},"ViewAction",{"@type":105,"mainEntity":106},"FAQPage",[107,113,117],{"name":108,"@type":109,"acceptedAnswer":110},"What mounting configurations do the D365PL(A) and DNRW duct smoke detectors support?","Question",{"text":111,"@type":112},"They use a pivoting housing to fit both square and rectangular duct footprints, and can be mounted to round or rectangular ducts.","Answer",{"name":114,"@type":109,"acceptedAnswer":115},"What environmental ratings and operating ranges are specified for these detectors?",{"text":116,"@type":112},"The detectors operate at airflow speeds of 100–4,000 ft/min, temperatures of -4°F–158°F (-20°C–70°C), and humidity of 0–93% (non-condensing). The DNRW model is NEMA-4 rated for watertight use.",{"name":118,"@type":109,"acceptedAnswer":119},"How does maintenance and tamper detection work on these models?",{"text":120,"@type":112},"An improved cover design isolates the sensor head for easier maintenance, and a cover tamper feature generates a trouble signal when the cover is removed or improperly installed.","https://schema.org",{"og:url":83,"og:type":123,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":125,"canonical":83},"index,follow",{"doc_id":127,"site_id":62},672614,1793600980,{"code":4,"msg":5,"data":130},{"doc_id":127,"user_id":131,"nickname":92,"user_avatar":132,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":8,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":14,"language":138,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":139,"faqs":140,"seo_title":141,"seo_description":67,"update_tm":128,"read_time":24},137441390410,"https://ap-avatar.wpscdn.com/avatar/2000252f4ab5702993?_k=1776741390130283984","D365PL(A) and DNRW Intelligent Non-relay Photoelectric Duct Smoke Detectors  \nAddressable Devices  \nThe Fire•Lite D365PL(A) intelligent non-relay photoelectric duct smoke detector and DNRW watertight non-relay photoelectric duct smoke detector feature a pivoting housing that fits both square and rectangular footprints capable of mounting to a round or rectangular duct.  \nThe DNRW duct smoke detector, with its NEMA-4 rating, is listed asa watertight, UV resistant enclosure providing protection against falling dirt, rain, and windblown dust, splashing and hose directed water, allowing operators to use the detector in the most extreme environments.  \nThese units sense smoke in the most challenging conditions, operating in airflow speeds of 100 to 4,000 feet per minute (0.5 – 20.32 m/s), temperatures of -4°F – 158°F (-20°C – 70°C), and a humidity range of 0 – 93 percent (non-condensing) .  \nAn improved cover design isolates the sensor head, which allows for ease of maintenance. A cover tamper feature indicates a trouble signal for a removed or improperly installed sensor cover. The housing provides a 3/4-inch conduit knockout and ample space to facilitate easy wiring and mounting of a relay module.  \nThe Fire•Lite D365PL(A) duct smoke detectors can be customized to meet local codes and specifications without additional wiring and are compatible with all previous models, including remote test accessories.  \nFeatures  \n• Photoelectric, integrated low-flow technology  \n• Air velocity rating from 100 ft/min – 4,000 ft/min (0.5 m/s – 20.32 m/s)  \n• Versatile mounting options: square or rectangular configuration  \n• Broad ranges for operating temperature (-4°F – 158°F, -20°C – 70°C) and humidity (0% – 93% non-condensing)  \n• Sampling tube installs from front or back of the detector with no tools required  \n• Cover tamper signal  \n• Increased wiring space with a newly added 3/4\" conduit knockout  \n• Easily accessible code wheels on sensor head (Included with D365PL/D365PLA)  \n• Clear cover for convenient visual inspection (D365PL(A) only)  \n• Remote testing capability  \n• Requires com line power only  \n• Housing accommodates an addressable relay module, sold separately,(CRF-300) for applications requiring a Form-C relay  \nSpecifications  \nSize: (Rectangle) 14.38 in (37 cm) Length; 5 in (12.7 cm) Width, 2.5 in (6 .6 cm) Depth  \nSize: (Square) 7.75 in (19.7 cm) Length; 9 in (22.9 cm) Width; 2.5 in (6 .35 cm) Depth  \nWeight: 1.6 lb (0.73 kg)  \nOperating Temperature Range: -4°F – 158°F (-20°C – 70°C) Storage Temperature Range: -22°F – 158°F (-30°C – 70°C) Operating Humidity Range: 0% – 93% relative humidity (non-condensing)  \nAir Duct Velocity: 100 – 4,000 ft/min (0.5 – 20.32 m/s)  \nAccessories  \nFire•Lite provides system flexibility with a variety of accessories, including two remote test stations and different means of visible and audible system annunciation. As with our duct smoke detectors, all duct smoke detectors accessories are UL listed.  \nACCESSORY CURRENT LOADS AT 24 VDC  \n\n| Device | Standby | Alarm |\n| --- | --- | --- |\n| RA100Z | 0mA | 12mA Max |\n| RTS151/RTS151KEY | 0mA | 12mA Max |\n\nAgency Listings and Approvals  \nConsult product manual for lists of compatible UL-Listed devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status.  \n• UL: S1059  \n• ULC: S1059  \n• CSFM: 3242-0075:0508  \n• FM approved  \nProduct Line Information NOTE: “A suffix indicates ULC listed model.  \nD365PL(A): Intelligent non-relay photoelectric low flow smoke detector housing. Includes SD365R(A)-IV detector.  \nDNRW: Watertight intelligent non-relay photoelectric low flow duct smoke detector housing. Requires photoelectric smoke detector (sold separately) . NEMA-4 rated.  \nSD365R(A)-IV: Remote test capable addressable low-profile photoelectric smoke detector; ivory; supports CLIP and LiteSpeed™ protocols  \nSD365R(A): Remote test capable addressable low-profi","cbCaipMTiBA7puab","https://ap.wps.com/l/cbCaipMTiBA7puab","pdf",161651,"English","# Features\n## Specifications\n## Accessories and Accessory Current Loads\n## Agency Listings and Approvals\n## Product Line Information","[{\"question\":\"What mounting configurations do the D365PL(A) and DNRW duct smoke detectors support?\",\"answer\":\"They use a pivoting housing to fit both square and rectangular duct footprints, and can be mounted to round or rectangular ducts.\"},{\"question\":\"What environmental ratings and operating ranges are specified for these detectors?\",\"answer\":\"The detectors operate at airflow speeds of 100–4,000 ft/min, temperatures of -4°F–158°F (-20°C–70°C), and humidity of 0–93% (non-condensing). The DNRW model is NEMA-4 rated for watertight use.\"},{\"question\":\"How does maintenance and tamper detection work on these models?\",\"answer\":\"An improved cover design isolates the sensor head for easier maintenance, and a cover tamper feature generates a trouble signal when the cover is removed or improperly installed.\"}]","D365PL(A) and DNRW Intelligent Non-relay Photoelectric Duct Smoke Detectors - Product Overview | PDF"]