[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-662794-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-662794-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","d1-distribution-main-valve-box-installed-as-per-standard-drawings","D.1.DISTRIBUTION MAIN - Valve box installed as per standard drawings","","Distribution main layout and assembly details for underground piping, including valve box installation, restrained flanged connections, fire hose thread adapter, reducing adapters, and MJ×MJ reducers. Specifies gasket type (full face), restrained ductile iron and rigid PVC components, 90° elbow with wedge-action restraint, and requirements for finished grade, sleeves, and direct-bury butterfly valve arrangements. References standard drawings 1.7 and 1.13, revision date Mar. 2023, and scale N.T.S.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/d1-distribution-main-valve-box-installed-as-per-standard-drawings/662794/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/d1-distribution-main-valve-box-installed-as-per-standard-drawings/662794.png","ImageObject",300,407,{"name":42,"@type":43},"（）","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":52,"interactionType":53,"userInteractionCount":22},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"What types of restrained connections are specified for the distribution main?","Question",{"text":62,"@type":63},"The drawing specifies fully restrained flanged connections, including full face flange gaskets and wedge-action restraint for mechanical joints.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"Which valve installation requirements are indicated?",{"text":67,"@type":63},"It indicates a valve box installed as per standard drawings, with direct-bury butterfly valve arrangements and finished grade considerations.",{"name":69,"@type":60,"acceptedAnswer":70},"What are the documented revision and scaling details?",{"text":71,"@type":63},"The revision date is Mar. 2023 and the scale is N.T.S.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},662794,1793222491,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,105,110,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},6,"Technology",50,"technology",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":107,"show_sort_weight":108,"slug":109},7,"Healthcare",40,"healthcare",{"id":111,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},8,30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":111,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":22,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":22,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":79,"read_time":30},5909898202386,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","100mmø×50mm øTHREADED FLANGE c/w100mm øFULL FACE(FF)FLANGE GASKET,100mm øCOMPACT RESTRAINED MJFA FLANGEADAPTER &65mm øFIRE HOSE THREAD(BAT)×50mmøNPT,MALE×MALE,BRASSSTANDARDREDUCING ADAPTER.METER BOXVALVE BOX INSTALLED AS PERSTANDARD DRAWINGS 1.7 &1.13  \nFINISHED GRADE150mm øRIGID PVCPIPE SLEEVEFULLY RESTRAINED100mm øMJ ×MJMIN 3 FULL PIPEDIRECT BURY BUTTERFLYLENGTHS OR AS—VALVE c/w MECHANICALPER DESIGN(WHICHJOINT WiTH WEDGEEVER IS GREATER)ACTION RESTRAINT—  \n(MIN.)  \n600  \n100mm øDUCTILECONCRETE THRUSTIRON FULLYRESTRAINED共BLOCK TYPICAL  \n# D.1.DISTRIBUTION MAIN\n\n6 mil POLY BETWEEN200     900      CONCRETE AND FITTINGMJ ×MJ REDUCER c/wMECHANICAL JOINT WiTH(MIN.(MIN.)WEDGE ACTION RESTRAINT100mm øDUCTILE IRON一100mm MJ x MJFULLY RESTRAINED90°ELBOW c/wMECHANICAL JOINT  \nWITH WEDGE ACTION  \nRESTRAINT  \n\n| CRD  \u003Cbr>Makingadifference...together   | 100mm FLUSH ASSEMBLY  \u003Cbr>100mm -300mm PIPE  \u003Cbr>(OUTSIDE PAVED AREA)   | revision date:    \u003Cbr>Mar.2023   | scale:  \u003Cbr>N.T.S.   |\n| --- | --- | --- | --- |\n|  |  | drawn:  \u003Cbr>PJ/DR/GA   | checked:  \u003Cbr>K.KONICEK   |\n|  |  | standard drawing no.  \u003Cbr>1.6   |  |","cbCaidn5r8yf0iSf","https://ap.wps.com/l/cbCaidn5r8yf0iSf","pdf",130422,"English","# D.1 DISTRIBUTION MAIN","[{\"question\":\"What types of restrained connections are specified for the distribution main?\",\"answer\":\"The drawing specifies fully restrained flanged connections, including full face flange gaskets and wedge-action restraint for mechanical joints.\"},{\"question\":\"Which valve installation requirements are indicated?\",\"answer\":\"It indicates a valve box installed as per standard drawings, with direct-bury butterfly valve arrangements and finished grade considerations.\"},{\"question\":\"What are the documented revision and scaling details?\",\"answer\":\"The revision date is Mar. 2023 and the scale is N.T.S.\"}]","D.1.DISTRIBUTION MAIN - Valve box installed as per standard drawings | PDF"]