[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-663630-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-663630-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","cvq-installation-and-maintenance-instructions-part-turn-control-valve-actuator","CVQ - Installation and maintenance instructions - Part-turn control valve actuator","","CVQ Part-turn control valve actuator manual covering installation, setup, operation, adjustment, and inspection of the Rotork CVQ-1200 and CVQ-2400 actuator range. Provides structured guidance on general information, enclosure materials, hazardous area approvals, storage and receiving/inspection, and health and safety requirements. Details actuator operation with local controls and optional Reserve Power Pack, commissioning and quick setup flows, mounting and cable connections, configuration and advanced features, diagnostics, and Rotork sales and service information.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/cvq-installation-and-maintenance-instructions-part-turn-control-valve-actuator/663630/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/cvq-installation-and-maintenance-instructions-part-turn-control-valve-actuator/663630.png","ImageObject",300,407,{"name":42,"@type":43},"cryingin4k","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-29","2026-10-28",true,{"@type":52,"interactionType":53,"userInteractionCount":33},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"What safety information must be followed before installing or maintaining the CVQ actuator?","Question",{"text":62,"@type":63},"The manual states that the important safety information must be thoroughly read and understood before installing, operating, or maintaining the equipment. Hazardous area access to live conductors is forbidden unless done under a special permit to work, and power should be isolated and the actuator moved to a non-hazardous area for repair or attention.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"Which CVQ models are covered by this manual?",{"text":67,"@type":63},"The manual covers the part-turn control valve actuator range (CVQ), specifically models CVQ-1200 and CVQ-2400.",{"name":69,"@type":60,"acceptedAnswer":70},"How are torque and position settings configured?",{"text":71,"@type":63},"All torque and position settings and actuator configuration are made using a non-intrusive Bluetooth® wireless device, typically a PC or laptop (not supplied), using Bluetooth wireless PC Enlight software available for free download.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},663630,1793229693,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,104,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":102,"slug":103},6,50,"technology",{"id":105,"doc_module":4,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},7,"Healthcare",40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":101,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":33,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":79,"read_time":144},137458181193,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","CVQ series  \nInstallation and maintenance instructions  \nPart-turn control valve actuator  \nSection Page Section Page  \n1. Introduction 3  \n2. General information 4  \n2.1 Enclosure materials 4  \n3. Hazardous area approvals 5  \n4. Storage 8  \n4.1 Receiving / inspection 8  \n4.2 Storage 8  \n4.3 Identification label 8  \n5. Health and safety 9  \n6. Operating your actuator 10  \n6.1 Local controls 11  \n6.2 Reserve Power Pack (optional) 13  \n7. Installation and setup guide 14  \n7.1 Commissioning 14  \n7.2 Quick setup flow chart 15  \n7.3 Mounting the actuator 16  \n7.4 Cable connections 18  \n7.5 Connection preparation 20  \n7.6 Reconnect or discover an actuator 21  \n7.7 Login 21  \n7.8 Stroke setup menu 23  \n7.9 Fitting actuator to valve 23  \n7.10 Align coupling-adjust stop bolts 25  \n7.11 Quick setup wizard 28  \n7.12 Manual setup flow chart 32  \n7.13 Manual setup 33  \n7.14 Configurations options  \nsetup flow chart 37  \n7.15 File 38  \n7.16 Macro update 40  \n7.17 Setup 40  \n7.18 Control 40  \n7.19 Valve actions 41  \n7.20 Input / output setup 42  \n7.21 Fail modes 43  \n7.22 Advanced 1 44  \n7.23 Advanced 2 46  \n7.24 Characterisation 47  \n7.25 RIRO (Remote Inputs & Remote Outputs) 50  \n7.26 Change password 52  \n7.27 Control and diagnostics options  \nsetup flow chart 53  \n7.28 Diagnostic menus 56  \n8. Rotork sales and service 61  \nTHIS MANUAL CONTAINS IMPORTANT SAFETY INFORMATION. PLEASE ENSURE IT IS THOROUGHLY READ AND UNDERSTOOD BEFORE INSTALLING, OPERATING OR MAINTAINING THE EQUIPMENT.  \nDUE TO WIDE VARIATIONS IN THE TERMINAL NUMBERING OF ACTUATOR PRODUCTS, ACTUAL WIRING OF THIS DEVICE SHOULD FOLLOW THE PRINT SUPPLIED WITH THE UNIT.  \n2  CVQ installation and maintenance instructions  \nThis manual covers the part-turn control valve actuator range (CVQ) .  \nModels: CVQ-1200 and CVQ-2400  \nRefer to Rotork PUB042-001 for full specification.  \nBuilding on Rotork’s historical success with innovative technology, the CVQ offers a highly accurate and responsive method of automating control valves without the complexity and cost of a pneumatic supply. With an increased focus on production costs and efficiency, accurate control of the process variable is paramount.  \nWith resolution figures better than 0.1% and the ability to eliminate position overshoot, the Rotork CVA range helps to maximize product quality and plant capacity.  \nCVA range actuators are self contained, purpose designed and built for continuous remote electrical operation of control valves .  \nThe actuator comprises:  \n• DC brushless electric motor  \n• Reduction gearing with quadrant output gear  \n• Motor controller with speed, travel and torque limitation  \n• Electronic logic controls and monitoring facilities housedin a double-sealed watertight enclosure  \n• Hazardous area certification meeting international and national requirements  \nAll torque and position settings as well as configuration of the actuator are made using a non-intrusive Bluetooth® wireless device, typically a PC or laptop (not supplied) .  \nBluetooth wireless PC Enlight software is available for free download [from www.rotork.com](from www.rotork.com).  \n3  \nThis manual has been produced to enable a competent user to install, operate, adjust and inspect the Rotork range of Control Valve Actuators.  \nThe electrical installation, maintenance and use of these actuators should be carried out in accordance with the National Legislation and Statutory Provisions relating to the safe use of this equipment applicable to the site of installation.  \nFor the UK: Electricity at Work Regulations 1989 and the guidance given in the applicable edition of the ‘IEE Wiring Regulations’ should be applied. Also the user should be fully aware of their duties under the Health and Safety at Work Act 1974.  \nFor the USA: NFPA70, National Electrical Code® is applicable.  \nThe mechanical installation should be carried out as outlined in this manual and also in accordance with any relevant national standard codes of practice. If the actuator nam","cbCaio3aeSfunr8N","https://ap.wps.com/l/cbCaio3aeSfunr8N","pdf",5492066,64,"English","# 1. Introduction\n# 2. General information\n## 2.1 Enclosure materials\n# 3. Hazardous area approvals\n# 4. Storage\n## 4.1 Receiving / inspection\n## 4.2 Storage\n## 4.3 Identification label\n# 5. Health and safety\n# 6. Operating your actuator\n## 6.1 Local controls\n## 6.2 Reserve Power Pack (optional)\n# 7. Installation and setup guide\n## 7.1 Commissioning\n## 7.2 Quick setup flow chart\n## 7.3 Mounting the actuator\n## 7.4 Cable connections\n## 7.5 Connection preparation\n## 7.6 Reconnect or discover an actuator\n## 7.7 Login\n## 7.8 Stroke setup menu\n## 7.9 Fitting actuator to valve\n## 7.10 Align coupling-adjust stop bolts\n## 7.11 Quick setup wizard\n## 7.12 Manual setup flow chart\n## 7.13 Manual setup\n## 7.14 Configurations options setup flow chart\n## 7.15 File\n## 7.16 Macro update\n## 7.17 Setup\n## 7.18 Control\n## 7.19 Valve actions\n## 7.20 Input / output setup\n## 7.21 Fail modes\n## 7.22 Advanced 1\n## 7.23 Advanced 2\n## 7.24 Characterisation\n## 7.25 RIRO (Remote Inputs & Remote Outputs)\n## 7.26 Change password\n## 7.27 Control and diagnostics options setup flow chart\n## 7.28 Diagnostic menus\n# 8. Rotork sales and service","[{\"question\":\"What safety information must be followed before installing or maintaining the CVQ actuator?\",\"answer\":\"The manual states that the important safety information must be thoroughly read and understood before installing, operating, or maintaining the equipment. Hazardous area access to live conductors is forbidden unless done under a special permit to work, and power should be isolated and the actuator moved to a non-hazardous area for repair or attention.\"},{\"question\":\"Which CVQ models are covered by this manual?\",\"answer\":\"The manual covers the part-turn control valve actuator range (CVQ), specifically models CVQ-1200 and CVQ-2400.\"},{\"question\":\"How are torque and position settings configured?\",\"answer\":\"All torque and position settings and actuator configuration are made using a non-intrusive Bluetooth® wireless device, typically a PC or laptop (not supplied), using Bluetooth wireless PC Enlight software available for free download.\"}]","CVQ - Installation and maintenance instructions - Part-turn control valve actuator | PDF",161]