[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-662672-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-662672-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","csu-cd-production-manual-2015","CSU - CD - Production Manual - 2015","","CAD standards for construction documents issued by the Office of the University Architect, focusing on creating consistent, compatible Cleveland State record drawing CAD files. The manual defines requirements for drawing formats, composition and naming, title block information, and layering standards, including model and paper space usage and external references. It also specifies drafting submission practices such as breaking multi-sheet files into single-sheet deliveries, purging unused data, and using approved disclaimer language in all construction documents.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/csu-cd-production-manual-2015/662672/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/csu-cd-production-manual-2015/662672.png","ImageObject",300,407,{"name":42,"@type":43},"Aditya","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":52,"interactionType":53,"userInteractionCount":33},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"What is the purpose of these CAD standards for construction documents?","Question",{"text":62,"@type":63},"They promote the development of CAD drawings suitable for Cleveland State record drawings and ensure consistency and compatibility with existing CSU CAD documentation.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"Which CAD drawing file formats are acceptable for submission?",{"text":67,"@type":63},"Only AutoCAD 2011 DWG formats are acceptable, and REVIT files should also be submitted. AutoCAD DWF may be requested in addition to DWG.",{"name":69,"@type":60,"acceptedAnswer":70},"What are the key requirements for CAD drawing composition and naming before delivery?",{"text":71,"@type":63},"Each file should contain only one drawing and one title block, multiple-sheet files should be split into single-sheet drawings, unused/empty data should be purged, and the drawing name should include the sheet number first followed by the drawing title.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},662672,1793221524,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,104,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":102,"slug":103},6,50,"technology",{"id":105,"doc_module":4,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},7,"Healthcare",40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":101,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":33,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":79,"read_time":144},962085564549,"https://ap-avatar.wpscdn.com/davatar_085a072bc5b1113ac321206ff7593b45","Office of the University Architect  \nCAD STANDARDS FOR CONSTRUCTION  \nDOCUMENTS  \nPUBLISHED:  \nMAY 2015  \nTABLE OF CONTENTS  \nSection 1 General Requirements  \n1.1 Overview p. 3  \n1.2 Drawings Format p. 3  \n1.3 Drawing Composition/ Naming p. 3  \n1.4 Title Block Information p. 4  \n1.5 Layering Standards p. 4  \n1.6 Entity Properties p. 4  \n1.7 Model and Paper Space Usage p. 5  \n1.8 External References – XREF’S & Images p. 5  \n1.9 CAD TM Drawing Support Files p. 5  \n1.10 File Transmittal P. 5‐6 1.11 Submittal Requirements p. 6‐7  \nSection 2 Layering Standards (General)  \n2.1 Layer Name Format p. 7‐8  \n2.2 Layer Standards – Detailed p. 8  \nSection 3 Sheet Naming  \n3.1 General Requirements p. 8  \n3.2 Sheet Identification p. 8‐9 Section 4 Building Information Standards (BIM)  \n4.1 General Requirements p. 9  \nAppendix  \nA Title Sheet and Border Standards p. 10  \nB Electronic File Quality Assurance Checklist p. 11  \nCleveland State University – CAD Standards for Construction Documents  \n5/1/2015  \nGeneral Requirements  \n1.1 Overview: These standards are issued to promote the development of CAD drawings suitable for use in the Cleveland State Office of the University Architect’s record drawings. Consistency and compatibility with existing Cleveland State CAD documents can only be achieved when these standards are strictly adhered to. Electronic drawings produced and submitted in accordance with these standards have significantly greater value to the university, Architects, Engineers, and Contractors delivering CAD documentation to Cleveland State. Other Cleveland State contracts or construction guidelines may reference this document.  \nAll design and construction drawings submitted to Cleveland State shall follow the CAD standards outlined in this document. Each of the following sections contains the most essential criteria for developing CAD drawings for use at Cleveland State.  \nUse Disclaimer:  \nAll construction documents must include the following disclaimer: “Warning: This document may contain sensitive and/or proprietary information and therefore must be treated as a confidential document. Acceptance of this document constitutes an agreement that this document and the information contained herein shall be maintained and transmitted in a confidential manner. No part of this document shall be reproduced, released or distributed without the express written permission of Cleveland State and any distribution to non‐CSU entities or persons must be subject to a written confidentiality agreement.”  \n1.2 Drawing Format: Only the CAD drawing file formats listed below are acceptable, other formats are not acceptable without the prior consent of the Office of the University Architect.  \n􀂃 AutoCAD™ 2011 DWG formats only. (In addition, please submit any REVIT files)  \n􀂃 AutoCAD™ ‐ DWF format may be requested in addition to the DWG (see Section 1. 11)  \n1.3 Drawing Composition/Naming: CAD drawings created outside of Cleveland State sometimes contain more than one drawing sheet per file. While this may facilitate the production of construction documents, it can impede the archival process, and create content discrepancies. To minimize potential problems:  \n􀂃 Prior to delivery to Cleveland State, CAD files containing multiple drawing sheets shall be broken down into separate drawings containing single sheets.  \n􀂃 CAD files delivered to Cleveland State shall contain only one drawing and one title block per file.  \n􀂃 All CAD drawings shall be purged of empty, unused, or non‐essential drawing data prior to submittal to Cleveland State. This includes all unused layers, linetypes, blocks, fonts and entities.  \n􀂃 CAD drawings shall not contain any frozen layers. All unused entities on frozen layers should be erased, and the empty layers purged.  \n􀂃 CAD drawings shall not contain multiple overlaid lines or lines with multiple segments unless the overlaid lines or adjacent line segments are assigned to different layers.  \n􀂃 Survey data shall be included i","cbCaisMd3xOzxlFx","https://ap.wps.com/l/cbCaisMd3xOzxlFx","pdf",363988,11,"English","# Section 1 General Requirements\n## 1.1 Overview\n## 1.2 Drawings Format\n## 1.3 Drawing Composition/ Naming\n## 1.4 Title Block Information\n## 1.5 Layering Standards\n## 1.6 Entity Properties\n## 1.7 Model and Paper Space Usage\n## 1.8 External References – XREF’S & Images\n## 1.9 CAD TM Drawing Support Files\n## 1.10 File Transmittal\n## 1.11 Submittal Requirements\n# Section 2 Layering Standards (General)\n## 2.1 Layer Name Format\n## 2.2 Layer Standards – Detailed\n# Section 3 Sheet Naming\n## 3.1 General Requirements\n## 3.2 Sheet Identification\n# Section 4 Building Information Standards (BIM)\n## 4.1 General Requirements\n# Appendix\n## A Title Sheet and Border Standards\n## B Electronic File Quality Assurance Checklist\n## C Cleveland State University – CAD Standards for Construction Documents","[{\"question\":\"What is the purpose of these CAD standards for construction documents?\",\"answer\":\"They promote the development of CAD drawings suitable for Cleveland State record drawings and ensure consistency and compatibility with existing CSU CAD documentation.\"},{\"question\":\"Which CAD drawing file formats are acceptable for submission?\",\"answer\":\"Only AutoCAD 2011 DWG formats are acceptable, and REVIT files should also be submitted. AutoCAD DWF may be requested in addition to DWG.\"},{\"question\":\"What are the key requirements for CAD drawing composition and naming before delivery?\",\"answer\":\"Each file should contain only one drawing and one title block, multiple-sheet files should be split into single-sheet drawings, unused/empty data should be purged, and the drawing name should include the sheet number first followed by the drawing title.\"}]","CSU - CD - Production Manual - 2015 | PDF",28]