[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-662671-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-662671-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","cscs-2024-edition-standard-drawings","CSCS 2024 Edition Standard Drawings","","Index-style listing of standard drawing specifications for conduit, duct, and vault/maintenance-hole components across multiple voltage classes (including 600V, 4.8kV, 34.5kV, and higher). Entries cover termination and line offset details, baffle boards, precast vault neck and cover systems, handholes and deep-recess variants, transformer pad general requirements, standpipe vent structures, and related placement or installation guidance. Also included are cable trench and transition boxes, ventilation conditions, ladder installation, fire barrier and service assemblies, and power-line clearance/easement drawing references.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/cscs-2024-edition-standard-drawings/662671/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/cscs-2024-edition-standard-drawings/662671.png","ImageObject",300,407,{"name":42,"@type":43},"Sarah ","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":52,"interactionType":53,"userInteractionCount":30},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"What kinds of electrical site standard drawings are listed in this document?","Question",{"text":62,"@type":63},"It lists standard drawing specifications covering conduit termination and offsets, duct and vent details, precast vault and maintenance-hole components, handholes, transformer pad requirements, standpipe vents, and related cable trench and transition elements.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"Does the index include drawings for multiple voltage levels?",{"text":67,"@type":63},"Yes. The entries explicitly reference multiple electrical levels such as 600V, 4.8kV, and 34.5kV, and also include higher transmission-related items.",{"name":69,"@type":60,"acceptedAnswer":70},"Are installation-related guidelines included alongside component drawings?",{"text":71,"@type":63},"Yes. The index contains items that reference installation/placement details and guidelines, including ladder installation for vaults, residential underground standard structure placement conduit trench details, traffic conditions for vents, and power line clearance/easement drawings.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},662671,1793221511,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,105,110,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},6,"Technology",50,"technology",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":107,"show_sort_weight":108,"slug":109},7,"Healthcare",40,"healthcare",{"id":111,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},8,30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":111,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":30,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":79,"read_time":144},962085320529,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","| ITEM\\#   | SPEC NUMBER(DATE)   | DESCRIPTION   |\n| --- | --- | --- |\n| 1   | Title Sheet of Drawings   | Revision Information of Drawings   |\n| 2   | 1-120.1(12-13-93)   | Conduit Termination Dead End   |\n| 3   | 1-161(01-06-83)   | Conduit Line Offsets,600V&4.8kV Lines   |\n| 4   | 1-166(01-06-68)   | Conduit Line Offsets,34.5kV Lines   |\n| 5   | 1-225(11-15-84)   | Baffle Board   |\n| 6   | 1-802(05-03-21)   | Precast Vault Neck &Cover Details   |\n| 7   | 1-802.1(05-03-21)   | Precast Neck Installation &Grade Rings   |\n| 8   | 1-802.2(05-03-21)   | Maintenance Hole/Vault Cover W/Restraining System   |\n| 9   | 1-824(06-05-80)   | Traffic Conditions for Vents   |\n| 10   | 2-210(08-25-22)   | Duct Mandrels   |\n| 11   | 2-361(12-07-12)   | Ladder Installation for Vault/Maintenance-Hole   |\n| 12   | 2-361.2(11-30-12)   | Ladder Installation for Vault &Manholes(Neck greater than 4 feet)   |\n| 13   | C702-50(01-30-13)   | Concrete Mixtures   |\n| 14   | P721-00 thru-00.8(04-01-21)   | Transformer Pad General Requirements (Previously C721-01 thru-01.8)   |\n| 15   | C730-10(02-13-19)   | 12”Standpipe Architectural Vents,Structures   |\n| 16   | E438(10-01-84)   | Precast Handhole   |\n| 17   | E459(09-24-24)   | Precast Handhole w/Deep Recess   |\n| 18   | E491(05-07-21)   | Precast Handhole w/Deep Recess   |\n| 19   | E492(10-06-96)   | Precast Handhole 2’-0”X3'-0”X24”Deep Bottomless   |\n| 20   | E541(10-08-96)   | Precast Handhole w/Deep Recess Intercepting Type   |\n| 21   | E617(09-16-98)   | Fiberglass Reinforced Polymer Handhole 24”X36”X 36”   |\n| 22   | E619(01-15-98)   | Fiberglass Reinforced Polymer Handhole 30”X48”X 36”   |\n| 23   | E621(01-15-98)   | Fiberglass Reinforced Polymer Handhole 36”X60”X48”   |\n| 24   | G284(09-24-15)   | Precast Vaults Rectangular   |\n| 25   | G286(05-07-21)   | Precast Vault Parkway Type 4'-0”X6'-6”X7'-0”   |\n| 26   | G292(02-28-01)   | Precast Vault 8'X14’X9'-4”Panel Type   |\n| 27   | G322(03-13-97)   | Precast Maintenance Hole 4'-0”X6'-6”Rectangular   |\n| 28   | G328(03-13-97)   | Precast Station Entrance Maintenance Hole 4.8kV Cable Lines   |\n| 29   | G334(07-23-18)   | Precast Maintenance Hole Rectangular Panel Type   |\n| 30   | G353(10-09-94)   | Underground Transformer Silo   |\n| 31   | G354(06-06-14)   | Precast Maintenance Hole 5'-0”X10'-6”X7'-0”   |\n| 32   | G384(07-15-02)   | Precast Maintenance Hole 6’X10'Panel Type 34.5KV   |\n| 33   | H168(01-14-08)   | Residential UG Standard Structures Placement Conduit Trench Details   |\n| 34   | H171(09-18-12)   | Precast Vaults 4.8kV Commercial   |\n| 35   | H172(09-24-15)   | Precast Vault(Intercept Tunnel Type)34.5KV&4.8kV Commercial   |\n| 36   | H202(12-18-23)   | Precast Maintenance Hole 8'-0”X16'-0”w/Terminations   |\n| 37   | H204(05-26-21)   | Precast Maintenance Hole Tunnel Type 6'-0”X16'-0”X9'-0”   |\n| 38   | H210(07-01-23)   | Precast Maintenance Hole 6'-0”X 20’-0”W/Terminations   |\n| 39   | H217(10-31-96)   | Precast Maintenance Hole Tub-Type 7'-0”X14'-0”X9'-0”   |\n| 40   | H242(01-07-23)   | Guidelines for UG Elec.Dist.Const.in Areas Where Soil Gas is Present   |\n| 41   | H244(09-09-10)   | Precast Maintenance Hole 7'-0”X18'-0”W/Terminations   |\n| 42   | H248(12-03-13)   | Precast Maintenance Hole 230 KV Transmission 30'-0”X8'-0”X9'-4\"   |\n| 43   | OA006-01(08-13-12)   | Power Line Clearances and Easement Drawing   |\n| 44   | UA730-01(04-24-09)   | 12”Architectural Standpipe Vent(Polyethylene)   |\n| 45   | UB721-01(11-08-22)   | 4’X4'-6”Precast Pad w/Pull Box f/Padmount Transformer   |\n| 46   | UB721-02(11-05-22)   | 4’X7'Precast Pad w/Handhole f/Padmount Transformer   |\n| 47   | UB721-03(11-08-22)   | 6'X8'Precast Pad w/Handhole f/Padmount Transformer   |\n| 48   | UB721-07(11-08-22)   | 8'X10'Precast Pad w/Handhole f/Padmount Transformer   |\n| 49   | UB721-08(11-01-22)   | 9’X15'Precast Pad f/Padmount Transformer   |\n| 50   | UB721-09(11-16-22)   | 5’X7'Precast Pad w/Handhole f/Padmount Tfr or Padmount SF6 Switchgear   |\n\n(INDEX PAGE1OF 2)","cbCairRtkoDCRSh9","https://ap.wps.com/l/cbCairRtkoDCRSh9","pdf",16982830,134,"English","# Drawing Specification Index\n## Title Sheet and Revision Information\n## Conduit, Duct, and Ventilation Details\n## Precast Vaults, Vault Necks, and Covers\n## Handholes and Cable-Related Components\n## Transformer Pad Requirements and Standpipe Vents\n## Fire Barriers, Grounding, and Clearances","[{\"question\":\"What kinds of electrical site standard drawings are listed in this document?\",\"answer\":\"It lists standard drawing specifications covering conduit termination and offsets, duct and vent details, precast vault and maintenance-hole components, handholes, transformer pad requirements, standpipe vents, and related cable trench and transition elements.\"},{\"question\":\"Does the index include drawings for multiple voltage levels?\",\"answer\":\"Yes. The entries explicitly reference multiple electrical levels such as 600V, 4.8kV, and 34.5kV, and also include higher transmission-related items.\"},{\"question\":\"Are installation-related guidelines included alongside component drawings?\",\"answer\":\"Yes. The index contains items that reference installation/placement details and guidelines, including ladder installation for vaults, residential underground standard structure placement conduit trench details, traffic conditions for vents, and power line clearance/easement drawings.\"}]","CSCS 2024 Edition Standard Drawings | PDF",338]