[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-664056-105":59,"doc-detail-664056-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","cscs-2022-edition-standard-drawings","CSCS 2022 Edition Standard Drawings","","CSCS 2022 Edition Standard Drawings provides a structured index of electrical underground and precast infrastructure drawing details. It lists spec numbers with revision dates and concise descriptions covering conduit terminations and offsets, duct and transformer-related pad and vault requirements, handholes in multiple material and recess configurations, and maintenance hole/vault cover and ladder installation details. The drawings also address underground vent structures, traffic and placement conditions, power line clearances and easements, concrete mixtures, cable trench and transition boxes, and ground plane/fire barrier considerations.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/cscs-2022-edition-standard-drawings/664056/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/cscs-2022-edition-standard-drawings/664056.png","ImageObject",300,407,{"name":92,"@type":93},"\tCallum ","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-29",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What information does the document index include for each drawing?","Question",{"text":112,"@type":113},"Each entry lists an item number, a specification number with a date, and a short description of the drawing content (often including construction type and dimensions).","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What handhole configurations are listed?",{"text":117,"@type":113},"Entries cover precast handholes including versions with deep recesses, bottomless designs with specified dimensions, intercepting types, and fiberglass reinforced polymer handholes with multiple size configurations.",{"name":119,"@type":110,"acceptedAnswer":120},"Does the document address clearances and installation constraints?",{"text":121,"@type":113},"Yes. It includes items such as power line clearances and easement drawings, minimum overall spatial clearances, and guidelines for construction areas where soil gas is present.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},664056,1793238001,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144},137451211410,"https://ap-avatar.wpscdn.com/avatar/2000bb0a9246f588df?x-image-process=image/resize,m_fixed,w_180,h_180&k=1786362646172706240","| ITEM\\#   | SPEC NUMBER(DATE)   | DESCRIPTION   |\n| --- | --- | --- |\n| 1   | Title Sheet of Drawings   | Revision Information of Drawings   |\n| 2   | 1-120.1(12-13-93)   | Conduit Termination Dead End   |\n| 3   | 1-161(01-06-83)   | Conduit Line Offsets,600V&4.8kV Lines   |\n| 4   | 1-166(01-06-68)   | Conduit Line Offsets,34.5kV Lines   |\n| 5   | 1-225(11-15-84)   | Baffle Board   |\n| 6   | 1-802(05-03-21)   | Precast Vault Neck &Cover Details   |\n| 7   | 1-802.1(05-03-21)   | Precast Neck Installation &Grade Rings   |\n| 8   | 1-802.2(05-03-21)   | Maintenance Hole/Vault Cover W/Restraining System   |\n| 9   | 1-824(06-05-80)   | Traffic Conditions for Vents   |\n| 10   | 2-210(08-16-12)   | Duct Mandrels   |\n| 11   | 2-361(12-07-12)   | Ladder Installation for Vault/Maintenance-Hole   |\n| 12   | 2-361.2(11-30-12)   | Ladder Installation for Vault &Manholes (Neck greater than 4 feet)   |\n| 13   | C702-50(01-30-13)   | Concrete Mixtures   |\n| 14   | C721-01 thru-01.8(09-28-12)   | Transformer Pad General Requirements   |\n| 15   | C730-10(02-13-19)   | 12”Standpipe Architectural Vents,Structures   |\n| 16   | E438(10-01-84)   | Precast Handhole   |\n| 17   | E459(05-10-21)   | Precast Handhole w/Deep Recess   |\n| 18   | E491(05-07-21)   | Precast Handhole w/Deep Recess   |\n| 19   | E492(10-06-96)   | Precast Handhole 2’-0”X3'-0”X24”Deep Bottomless   |\n| 20   | E541(10-08-96)   | Precast Handhole w/Deep Recess Intercepting Type   |\n| 21   | E617(09-16-98)   | Fiberglass Reinforced Polymer Handhole 24”X36”X 36”   |\n| 22   | E619(01-15-98)   | Fiberglass Reinforced Polymer Handhole 30”X48”X 36”   |\n| 23   | E621(01-15-98)   | Fiberglass Reinforced Polymer Handhole 36”X60”X48”   |\n| 24   | G284(09-24-15)   | Precast Vaults Rectangular   |\n| 25   | G286(05-07-21)   | Precast Vault Parkway Type 4'-0”X6'-6”X7'-0”   |\n| 26   | G292(02-28-01)   | Precast Vault 8'X14’X9'-4”Panel Type   |\n| 27   | G322(03-13-97)   | Precast Maintenance Hole 4'-0”X6'-6”Rectangular   |\n| 28   | G328(03-13-97)   | Precast Station Entrance Maintenance Hole 4.8kV Cable Lines   |\n| 29   | G334(07-23-18)   | Precast Maintenance Hole Rectangular Panel Type   |\n| 30   | G353(10-09-94)   | Underground Transformer Silo   |\n| 31   | G354(06-06-14)   | Precast Maintenance Hole 5'-0”X10'-6”X7'-0”   |\n| 32   | G384(07-15-02)   | Precast Maintenance Hole 6’X10'Panel Type 34.5KV   |\n| 33   | H168(01-14-08)   | Residential UG Standard Structures Placement Conduit Trench Details   |\n| 34   | H171(09-18-12)   | Precast Vaults 4.8kV Commercial   |\n| 35   | H172(09-24-15)   | Precast Vault(Intercept Tunnel Type)34.5KV&4.8kV Commercial   |\n| 36   | H202(02-06-18)   | Precast Maintenance Hole 8'-0”X 16'-0”w/Terminations   |\n| 37   | H204(05-26-21)   | Precast Maintenance Hole Tunnel Type 6'-0”X16'-0”X9'-0”   |\n| 38   | H217(10-31-96)   | Precast Maintenance Hole Tub-Type 7'-0”X14’-0”X9'-0”   |\n| 39   | H242(06-20-19)   | Guidelines for UG Elec.Dist.Const.in Areas Where Soil Gas is Present   |\n| 40   | H244(09-09-10)   | Precast Maintenance Hole 7'-0”X18'-0”W/Terminations   |\n| 41   | OA006-01(08-13-12)   | Power Line Clearances and Easement Drawing   |\n| 42   | UA730-01(04-24-09)   | 12”Architectural Standpipe Vent(Polyethylene)   |\n| 43   | UB721-01(06-11-07)   | 4’X4'-6”Precast Pad w/Pull Box f/Padmount Transformer   |\n| 44   | UB721-02(12-28-11)   | 4’X7'Precast Pad w/Handhole f/Padmount Transformer   |\n| 45   | UB721-03(12-28-11)   | 6’X8'Precast Pad w/Handhole f/Padmount Transformer   |\n| 46   | UB721-07(09-10-19)   | 8'X10'Precast Pad w/Handhole f/Padmount Transformer   |\n| 47   | UB721-08(12-28-11)   | 9'X15'Precast Pad f/Padmount Transformer   |\n| 48   | UB721-09(12-28-11)   | 5’X7’Precast Pad w/Handhole f/Padmount Tfr or Padmount SF6 Switchgear   |\n| 49   | UB721-10(12-28-11)   | 7’X13'Precast Pad f/Single Line Padmount Switchgear   |\n| 50   | UB721-11(12-28-11)   | 10’X10'-6”Precast Pad w/7'-10”X8'-6”Opening F/Dual Line Padmount Tfr.   |\n\n(INDEX PAGE1OF 2)  \n\n| ITEM\\#   |","cbCaievoaVfiQX4Q","https://ap.wps.com/l/cbCaievoaVfiQX4Q","pdf",14855318,124,"English","# Drawing Index\n## Title Sheet of Drawings\n## Revision Information of Drawings","[{\"question\":\"What information does the document index include for each drawing?\",\"answer\":\"Each entry lists an item number, a specification number with a date, and a short description of the drawing content (often including construction type and dimensions).\"},{\"question\":\"What handhole configurations are listed?\",\"answer\":\"Entries cover precast handholes including versions with deep recesses, bottomless designs with specified dimensions, intercepting types, and fiberglass reinforced polymer handholes with multiple size configurations.\"},{\"question\":\"Does the document address clearances and installation constraints?\",\"answer\":\"Yes. It includes items such as power line clearances and easement drawings, minimum overall spatial clearances, and guidelines for construction areas where soil gas is present.\"}]","CSCS 2022 Edition Standard Drawings | PDF",312]