[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-640401-105":59,"doc-detail-640401-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","cs110-electric-field-meter-product-manual-revision-112023","CS110 Electric Field Meter - Product Manual - Revision 11/2023","","CS110 Electric Field Meter product manual describes how the instrument measures electric fields and forecasts lightning likelihood. It explains operating principles including a reciprocating shutter and use of a zero-field reference to improve dc error performance. Key specifications cover measurement range, one-second sampling, and detection radius with stated efficiency figures. The manual provides safety precautions, initial inspection guidance, detailed installation and power considerations, programming instructions, operation including lightning detection and warning logic, plus maintenance procedures such as calibration, desiccant changes, cleaning, and troubleshooting.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/cs110-electric-field-meter-product-manual-revision-112023/640401/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/cs110-electric-field-meter-product-manual-revision-112023/640401.png","ImageObject",300,407,{"name":92,"@type":93},"Cipher","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-26","2026-10-22",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What does the CS110 Electric Field Meter measure and what does it forecast?","Question",{"text":112,"@type":113},"The CS110 measures the electric field and forecasts the likelihood of lightning. Higher electric-field values indicate a greater probability of lightning.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What are the CS110 measurement range and lightning detection capabilities?",{"text":117,"@type":113},"The CS110 measurement range is -25,000 to 25,000 V/m with measurements every second. It can detect cloud-to-ground and cloud-to-cloud lightning strikes within a 25-mile radius, with efficiency figures varying by distance.",{"name":119,"@type":110,"acceptedAnswer":120},"Why is the CS110’s reciprocating shutter design important?",{"text":121,"@type":113},"The shutter opens and closes by 45° during measurements and is electrically connected to ground, creating an ultra-reliable electrical ground connection. Using a zero-field (closed shutter) reference improves dc error performance compared with traditional rotating-vane field mills.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},640401,1793052213,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},687208528416,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","PRODUCT MANUAL  \n CS110  \nElectric Field Meter  \nRevision: 11/2023 Copyright © 2023 Campbell Scientific, Inc.  \nPlease read first  \nAbout this manual  \nPlease note that this manual was produced by Campbell Scientific Inc. primarily for the North American market. Some spellings, weights and measures may reflect this. In addition, while most of the information in the manual is correct for all countries, certain information is specific to the North American market and so may not be applicable to European users. Differences include the U. S. standard external power supply details where some information (for example the AC transformer input voltage) will not be applicable for British/European use. Please note, however, that when a power supply adapter is ordered from Campbell Scientific it will be suitable for use in your country.  \nReference to some radio transmitters, digital cell phones and aerials (antennas) may also not be applicable according to your locality. Some brackets, shields and enclosure options, including wiring, are not sold as standard items in the European market; in some cases alternatives are offered.  \nRecycling information for countries subject to WEEE regulations 2012/19/EU  \nAt the end of this product’s life it should not be put in commercial or domestic refuse but sent for recycling. Any batteries contained within the product or used during the products life should be removed from the product and also be sent to an appropriate recycling facility, per The Waste Electrical and Electronic Equipment (WEEE) Regulations 2012/19/EU. Campbell Scientific can advise on the recycling of the equipment and in some cases arrange collection and the correct disposal of it, although charges may apply for some items or territories. For further support, please contact Campbell Scientific, or your local agent.  \nTable of Contents  \n1. Introduction  1  \n2. Precautions  1  \n2.1 Lightning safety  1  \n3. Initial inspection  2  \n3.1 Accessories  2  \n4. Overview  3  \n5. Specifications  5  \n6. Installation  6  \n6.1 Site selection  7  \n6.2 Installing the CS110  8  \n6.3 Power considerations  8  \n6.3.1 Connecting to AC power  9  \n6.4 Seal cable connectors  9  \n6.5 Programming  9  \n6.5.1 CS110() instruction  9  \n6.5.2 CS110Shutter instruction  10  \n6.5.3 Internal relative humidity sensor programming  10  \n6.5.4 Sensor programming  10  \n7. Operation  12  \n7.1 Measurement details  12  \n7.2 CS110 lightning detection example  15  \n7.3 Lightning warning levels  16  \n7.3.1 All Clear  17  \n7.3.2 Caution or Lightning Watch  17  \n7.3.3 Alarm or Lightning Warning  18  \n7.4 Lightning warning logic  18  \n7.5 Factory calibration of the CS110  20  \n7.6 Site correction  22  \n8. CS110 maintenance  25  \n8.1 Status codes  26  \n8.2 Changing desiccant  28  \n8.3 Cleaning the CS110 electrode head  29  \n8.4 Checking ground integrity  31  \n8.5 Protecting from corrosion and rust  32  \n8.6 Recalibration  32  \n8.7 Troubleshooting  33  \n9. References  33  \nAppendix A. Connector pin-outs  34  \nA.1 Sensor connectors  34  \nA.2 Power and communication connectors  36  \nAppendix B. Installing a CM106B tripod  39  \nB.1 Tripod base  39  \nB.2 Staking tripod feet  40  \nB.3 Tripod mast  40  \nB.4 Tripod grounding  41  \nAppendix C. Installing a CM110 tripod  43  \nC.1 Tripod base  43  \nC.2 Tripod mast  44  \nC.3 Staking tripod feet  45  \nC.4 Tripod grounding  46  \nAppendix D. Mounting the enclosure on a tripod  48  \nAppendix E. Installing a CM500-series pole  50  \nE.1 Installation in concrete foundation (without a pedestal)  50  \nE.2 Installation with a pedestal  51  \nE.3 Installation with concrete stud anchors and a pedestal  54  \nE.4 Pole grounding  55  \nAppendix F. Mounting the enclosure on a CM500-series pole  56  \nG. Installing an RA100 remote alarm  59  \nG.1 Mounting on a flat wall (RA1 option)  59  \nG.2 Mounting on a pole or tripod (RA2 option)  59  \nAppendix H. Installing the SG000 Strike Guard  60  \nAppendix I. CS110 as a slow antenna  61  \nI.1 Slow antenna response in ","cbCaidpHlrQgHLyH","https://ap.wps.com/l/cbCaidpHlrQgHLyH","pdf",16652543,91,"English","# 1. Introduction\n# 2. Precautions\n## 2.1 Lightning safety\n# 3. Initial inspection\n## 3.1 Accessories\n# 4. Overview\n# 5. Specifications\n# 6. Installation\n## 6.1 Site selection\n## 6.2 Installing the CS110\n## 6.3 Power considerations\n## 6.4 Seal cable connectors\n## 6.5 Programming\n# 7. Operation\n## 7.1 Measurement details\n## 7.2 CS110 lightning detection example\n## 7.3 Lightning warning levels\n## 7.4 Lightning warning logic\n## 7.5 Factory calibration of the CS110\n## 7.6 Site correction\n# 8. CS110 maintenance\n## 8.1 Status codes\n## 8.2 Changing desiccant\n## 8.3 Cleaning the CS110 electrode head\n## 8.4 Checking ground integrity\n## 8.5 Protecting from corrosion and rust\n## 8.6 Recalibration\n## 8.7 Troubleshooting\n# 9. References","[{\"question\":\"What does the CS110 Electric Field Meter measure and what does it forecast?\",\"answer\":\"The CS110 measures the electric field and forecasts the likelihood of lightning. Higher electric-field values indicate a greater probability of lightning.\"},{\"question\":\"What are the CS110 measurement range and lightning detection capabilities?\",\"answer\":\"The CS110 measurement range is -25,000 to 25,000 V/m with measurements every second. It can detect cloud-to-ground and cloud-to-cloud lightning strikes within a 25-mile radius, with efficiency figures varying by distance.\"},{\"question\":\"Why is the CS110’s reciprocating shutter design important?\",\"answer\":\"The shutter opens and closes by 45° during measurements and is electrically connected to ground, creating an ultra-reliable electrical ground connection. Using a zero-field (closed shutter) reference improves dc error performance compared with traditional rotating-vane field mills.\"}]","CS110 Electric Field Meter - Product Manual - Revision 11/2023 | PDF",1792708957,229]