[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-512436-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-512436-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","cracking-down-on-pv-module-design-results-from-independent-testing-how-to-mitigate-cell-crack-risk","Cracking Down on PV Module Design - Results from Independent Testing - How to Mitigate Cell Crack Risk","","Cracks in solar cells are often invisible to the eye, yet they can reduce project energy yield and grow into long-term safety and reliability risks. This white paper explains how microcracks form from manufacturing, environmental, and handling causes, and how they can create hotspot effects, backsheet degradation, and potential ground and arc faults. It also summarizes field findings and design and climate trends that increase crack susceptibility, then outlines how PV module buyers and asset owners can mitigate risk with durable module choices.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/cracking-down-on-pv-module-design-results-from-independent-testing-how-to-mitigate-cell-crack-risk/512436/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/cracking-down-on-pv-module-design-results-from-independent-testing-how-to-mitigate-cell-crack-risk/512436.png","ImageObject",300,407,{"name":42,"@type":43},"percent12345","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-23","2026-10-06",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",8,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What are cell cracks (microcracks) and why do they matter?","Question",{"text":63,"@type":64},"Cell cracks are micro-level breaks caused by thermal and mechanical stress. They can restrict current flow, reduce energy production, and over time increase safety risks through related degradation mechanisms.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"What factors cause PV cell microcracks?",{"text":68,"@type":64},"Microcracks can result from manufacturing stresses (soldering, lamination pressures, handling), environmental conditions (temperature cycling, freeze-thaw, wind, snow and hail), and physical damage during transportation, installation, maintenance, or improper cleaning.",{"name":70,"@type":61,"acceptedAnswer":71},"How does PVEL's Mechanical Stress Sequence (MSS) relate to real-world cracking?",{"text":72,"@type":64},"PVEL's MSS combines static and dynamic mechanical loading with thermal cycling and humidity freeze to articulate and propagate cracks in susceptible modules, mirroring stresses that can occur in field conditions.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},512436,1792224046,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":55,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":102,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":143,"read_time":144,"preview_page_count":33,"preview_urls":145},1099529851338,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","Cracking Down on PV Module Design: Results from Independent Testing  \nCracks in solar cells are typically so small that they cannot be detected by eye – yet they can reduce a project’s energy yield and create safety issues over time. As climate change accelerates and weather patterns change, force majeure events such as wildfires, hail and other storms are more likely to affect solar power plants. This white paper explains the problem of cell cracks and discusses how PV module buyers, investors and asset owners can mitigate risk by investing in durable PV modules.  \nUnderstanding Cell Cracks  \nCell cracks, also known as microcracks, are caused by excessive thermal and mechanical stress that can result from several different factors:  \n• Manufacturing defects, such as stresses during cell soldering, lamination pressures and production line handling.  \n• Environmental conditions, such as daily temperature fluctuations, freeze-thaw cycles, wind, snow accumulation and hail.  \n• Physical damage, such as mishandling during transportation and/or installation, maintenance and/or improper cleaning.  \nThe PV module above was damaged by a tornado leading to cell cracks and inactive/dark areas. This EL image was taken by PVEL in the field.  \nCell cracks appear as dark, discolored, broken lines or areas in electroluminescence (EL) images. The module could produce less energy if these cracks restrict the flow of current through the cell.  \nA local hotspot may eventually form in the damaged area of the cell, which can accelerate backsheet degradation and delamination, eventually increasing the risk that ground and arc faults will occur.  \nCracking in the Field  \nA recent analysis of PV modules installed in various projects in Jordan found that severe cell cracks caused power losses as high as 9% in monocrystalline PERC modules after just four months of field exposure.1  \nThe study concluded that the number, size and shape of the cell cracks as well as busbar design all significantly influence the rate of power loss. It is important to note that, in many cases, power loss is realized over time, not in the space of a few months.  \nTechnology Trends and Risks  \nTwo recent trends in PV module design could significantly increase cell crack susceptibility, either alone or in combination. First, manufacturing shifts to larger format, higher-powered PV modules may increase cracking risks because:  \n• They contain larger silicon wafers that will be subjected to pressures over a larger surface area.  \n• The modules may be subject to more deflection during high wind and snow loads.  \n• To reduce the weight of these modules, some manufacturers are using thinner glass and/or thinner frames, which can reduce rigidity and durability.  \nSecond, reductions in inter-cell spacing, which are achieved through shingling and other cell-to-cell interconnection techniques, could increase mechanical stress on solar cells.  \nClimate Change and Extreme Weather  \nIn tandem with these PV manufacturing trends, the severity and frequency of extreme weather events are rising due to climate change, and more gigawatts of solar power are located within the likely paths of major storms. Hail, hurricanes, tornadoes and other high wind events are all known to cause glass and cell cracks in PV modules.  \nAsset owners can mitigate the risk of cell-level damage in their fleets by investing in more robust PV modules, especially for projects in storm-prone regions.  \n1 Matthar Bdour et al,“A Comprehensive Evaluation on Types of Microcracks and Possible Effects on Power Degradation in Photovoltaic Solar Panels.”  1  Sustainability 12 (2020): 6416. [https://www.mdpi.com/2071-1050/12/16/6416/htm](https://www.mdpi.com/2071-1050/12/16/6416/htm)  \nThe Mechanical Stress Sequence in PVEL's PV Module Product Qualification Program  \nModules tested for PVEL's Product Qualification Program (PQP) undergo the mechanical stress sequence (MSS), as shown in the diagram below. The MSS test combines sta","cbCaihh9H5yetD5o","https://ap.wps.com/l/cbCaihh9H5yetD5o","pdf",4296898,"English","# Understanding Cell Cracks\n# Cracking in the Field\n# Technology Trends and Risks\n# Climate Change and Extreme Weather\n# The Mechanical Stress Sequence in PVEL's PV Module Product Qualification Program\n## Testing at the Bill of Materials (BOM) Level","[{\"question\":\"What are cell cracks (microcracks) and why do they matter?\",\"answer\":\"Cell cracks are micro-level breaks caused by thermal and mechanical stress. They can restrict current flow, reduce energy production, and over time increase safety risks through related degradation mechanisms.\"},{\"question\":\"What factors cause PV cell microcracks?\",\"answer\":\"Microcracks can result from manufacturing stresses (soldering, lamination pressures, handling), environmental conditions (temperature cycling, freeze-thaw, wind, snow and hail), and physical damage during transportation, installation, maintenance, or improper cleaning.\"},{\"question\":\"How does PVEL's Mechanical Stress Sequence (MSS) relate to real-world cracking?\",\"answer\":\"PVEL's MSS combines static and dynamic mechanical loading with thermal cycling and humidity freeze to articulate and propagate cracks in susceptible modules, mirroring stresses that can occur in field conditions.\"}]","Cracking Down on PV Module Design - Results from Independent Testing - How to Mitigate Cell Crack Risk | PDF",1791270909,15,[146,150,154,158],{"page_no":22,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/2f54be23350352d8c3149c6634067194.webp",983,1272,{"page_no":26,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/9a44ec729c66ebc290b256d241608803.webp",982,1270,{"page_no":30,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/c9d7d5a58b58895a1aa005fe1ff93dce.webp",981,1269,{"page_no":33,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/c0bd6557fea79b3977524d331a190709.webp",980,1268]