[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-389823-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-389823-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","coronado-performance-data-read-online-free","Coronado-Performance-Data - read online free","","Anlin Coronado series performance data compares window styles and glazing options using engineering metrics such as U-factor and SHGC (with grid/no-grid variants), visible light transmittance (VLT), and IG values. Tables report air infiltration amounts, CRF and NFRC-related VLT figures, and UV-blocking information where applicable. STC ratings and related sound-pack specifications are provided across air and argon gas configurations and multiple laminated options for different product configurations.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/coronado-performance-data-read-online-free/389823/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/coronado-performance-data-read-online-free/389823.png","ImageObject",300,407,{"name":42,"@type":43},"Sophia Brooks","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-09-25",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",9,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What metrics are included in the Anlin Coronado performance data tables?","Question",{"text":63,"@type":64},"The tables include U-factor, SHGC (including grid/no-grid variants), VLT and IG values, air infiltration, NFRC-related VLT fields, and STC sound ratings.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How do the results vary by glazing option and gas type?",{"text":68,"@type":64},"Values are presented for different glazing package names and for air versus argon configurations, showing different U-factor, SHGC, and VLT/IG results by row.",{"name":70,"@type":61,"acceptedAnswer":71},"What is the role of air infiltration and STC ratings in these tables?",{"text":72,"@type":64},"Air infiltration quantifies the amount of air passing through the unit, while STC ratings measure the unit’s ability to reduce sound across the listed configurations.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},389823,1790695532,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,115,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":112,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":113,"slug":114},8,30,"research-report",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":112,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":102,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":143,"read_time":144,"preview_page_count":33,"preview_urls":145},962084925636,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","Anlin Coronado Series  \n\n| Style Glazing Option\u003Cbr>Air Argon\u003Cbr>U-factor SHGC No-Grid\u003Cbr>SHGC Grid\u003Cbr>VLT % VLT% VLT%\u003Cbr>IG\u003Cbr>NFRC NG\u003Cbr>NFRC G\u003Cbr>UV Block\u003Cbr>Air Infil\u003Cbr>CRF\u003Cbr>STC Ratings\u003Cbr>Standard Sound Pack Laminated 1/8 / 1/8 3/16 / 1/8 7/32 / 1/8 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| Double Slider | SunMatrix Plus | Air | .31 | .18 | .16 | 52 | 40 | 35 | 99% | 0.07 | 57 | 29 | 34 | 36 |\n| Double Hung | SunMatrix Plus | Air | .31 | .17 | .16 | 52 | 39 | 35 | 99% | 0.14 | 56 | 28 | 35 | 35 |\n| Picture Window | SunMatrix Plus | Air | .30 | .20 | .18 | 52 | 45 | 40 | 99% | \u003C.01 | 59 | 29 | 35 | 35 |\n| Casement | SunMatrix Plus | Air | .30 | .15 | .13 | 52 | 32 | 29 | 99% | \u003C.01 | 59 | 29 | 35 | 36 |\n| PW Casement | SunMatrix Plus | Air | .29 | .17 | .16 | 52 | 39 | 35 | 99% | \u003C.01 | 59 | 29 | 35 | 36 |\n| Awning | SunMatrix Plus | Air | .30 | .15 | .13 | 52 | 32 | 29 | 99% | 0.03 | 57 | 29 | 35 | 36 |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| Double Slider | SunMatrix Plus | Argon | .28 | .17 | .15 | 52 | 40 | 35 | 99% | 0.07 | 61 | 29 | 34 | 36 |\n| Double Hung | SunMatrix Plus | Argon | .28 | .17 | .15 | 52 | 39 | 35 | 99% | 0.14 | 60 | 28 | 35 | 35 |\n| Picture Window | SunMatrix Plus | Argon | .26 | .19 | .18 | 52 | 45 | 40 | 99% | \u003C.01 | 63 | 29 | 35 | 35 |\n| Casement | SunMatrix Plus | Argon | .27 | .14 | .13 | 52 | 32 | 29 | 99% | \u003C.01 | 63 | 29 | 35 | 36 |\n| PW Casement | SunMatrix Plus | Argon | .26 | .17 | .15 | 52 | 39 | 35 | 99% | \u003C.01 | 62 | 29 | 35 | 36 |\n| Awning | SunMatrix Plus | Argon | .27 | .14 | .13 | 52 | 32 | 29 | 99% | 0.03 | 61 | 29 | 35 | 36 |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| Double Slider | SunMatrix Plus/QT | Air | .26 | .17 | .15 | 49 | 39 | 35 | 99% | 0.07 | 45 | 29 | 34 | 36 |\n| Double Hung | SunMatrix Plus/QT | Air | .27 | .17 | .15 | 49 | 38 | 34 | 99% | 0.14 | 44 | 28 | 35 | 35 |\n| Picture Window | SunMatrix Plus/QT | Air | .24 | .19 | .17 | 49 | 44 | 39 | 99% | \u003C.01 | 46 | 29 | 35 | 35 |\n| Casement | SunMatrix Plus/QT | Air | .26 | .14 | .13 | 49 | 32 | 28 | 99% | \u003C.01 | 46 | 29 | 35 | 36 |\n| PW Casement | SunMatrix Plus/QT | Air | .24 | .17 | .15 | 49 | 38 | 34 | 99% | \u003C.01 | 45 | 29 | 35 | 36 |\n| Awning | SunMatrix Plus/QT | Air | .27 | .14 | .13 | 49 | 32 | 28 | 99% | 0.03 | 44 | 29 | 35 | 36 |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| Double Slider | SunMatrix Plus/QT | Argon | .24 | .17 | .15 | 49 | 39 | 35 | 99% | 0.07 | 49 | 29 | 34 | 36 |\n| Double Hung | SunMatrix Plus/QT | Argon | .24 | .17 | .15 | 49 | 38 | 34 | 99% | 0.14 | 48 | 28 | 35 | 35 |\n| Picture Window | SunMatrix Plus/QT | Argon | .21 | .19 | .17 | 49 | 44 | 39 | 99% | \u003C.01 | 50 | 29 | 35 | 35 |\n| Casement | SunMatrix Plus/QT | Argon | .24 | .14 | .13 | 49 | 32 | 28 | 99% | \u003C.01 | 50 | 29 | 35 | 36 |\n| PW Casement | SunMatrix Plus/QT | Argon | .22 | .17 | .15 | 49 | 38 | 34 | 99% | \u003C.01 | 49 | 29 | 35 | 36 |\n| Awning | SunMatrix Plus/QT | Argon | .25 | .14 | .13 | 49 | 32 | 28 | 99% | 0.03 | 49 | 29 | 35 | 36 |\n\n188  \nSHGC: Solar Heat Gain Coefficient  \nU-Factor: Insulating Value  \nIG VLT: Viewing Area, Visible Light Transmittance NFRC VLT: Entire Unit, Visible Light Transmittance  \nAIR INFILTRATION: Amount of air which passes through the unit STC RATING: Measurement of units ability to reduce sound 10.01.23  \nAnlin Coronado Series  \n\n| Style Glazing Option\u003Cbr>Air Argon\u003Cbr>U-factor SHGC No-Grid\u003Cbr>SHGC Grid\u003Cbr>VLT %\u003Cbr>IG\u003Cbr>VLT% VLT%\u003Cbr>NFRC NFRC\u003Cbr>NG G\u003Cbr>UV Block\u003Cbr>Air Infil\u003Cbr>CRF\u003Cbr>STC Ratings\u003Cbr>Standard Sound Pack Laminated 1/8 / 1/8 3/16 / 1/8 7/32 / 1/8 |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| Double Slider | Infinite Plus | Air | .31 | .21 | .19 | 65 | 49 | 44 | 95% | 0.07 | 57 | 29 | 34 | 36 |\n| Double Hung | Infinite Plus | Air | .31 | .21 | .19 | 65 | 49 | 43 | 95% | 0.14 | 56 | 28","cbCaic7TV3591VjC","https://ap.wps.com/l/cbCaic7TV3591VjC","pdf",283914,"English","# Window Performance Metrics\n## Glazing Options and Gas Types\n## Ratings and Key Definitions","[{\"question\":\"What metrics are included in the Anlin Coronado performance data tables?\",\"answer\":\"The tables include U-factor, SHGC (including grid/no-grid variants), VLT and IG values, air infiltration, NFRC-related VLT fields, and STC sound ratings.\"},{\"question\":\"How do the results vary by glazing option and gas type?\",\"answer\":\"Values are presented for different glazing package names and for air versus argon configurations, showing different U-factor, SHGC, and VLT/IG results by row.\"},{\"question\":\"What is the role of air infiltration and STC ratings in these tables?\",\"answer\":\"Air infiltration quantifies the amount of air passing through the unit, while STC ratings measure the unit’s ability to reduce sound across the listed configurations.\"}]","Coronado-Performance-Data - read online free | PDF",1790327808,15,[146,150,154,158],{"page_no":22,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/0f136104d5d76ddc91dc5eacd4ad2b94.webp",983,759,{"page_no":26,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/57524aff35d538143fe7f0803287c607.webp",982,758,{"page_no":30,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/b616a8db94b646e22d5f24fcb1ba15b0.webp",981,757,{"page_no":33,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/a5d996fdef136971f80414c0bb4e54a0.webp",980,756]