[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-646937-105":59,"doc-detail-646937-en":129},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":122,"head_meta":124,"extra_data":126,"updated_unix":128},105,"en","contractor-safety-manual-revision-14-january-2023","Contractor Safety Manual - Revision 14 January 2023","","Contractor Safety Manual (TD&C and Corporate Resources) sets mandatory health and safety requirements for contractors working on sites, including documentation and monitoring, defined contractor responsibilities, and qualification expectations for electrical work. It provides procedures for fitness for duty, pre-job brief and job hazard analysis, confined space entry, lockout/tagout, and controls for excavation, scaffolding, PPE, respiratory and fall protection. It also covers housekeeping, GHS, driving and facility access, emergencies, fire protection, electrical safety and arc flash, hazardous materials, asbestos, temperature extremes, and incident reporting.",{"@graph":69,"@context":121},[70,84,104],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/contractor-safety-manual-revision-14-january-2023/646937/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":98,"encodingFormat":97,"isAccessibleForFree":99,"interactionStatistic":100},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/contractor-safety-manual-revision-14-january-2023/646937.png","ImageObject",300,407,{"name":92,"@type":93},"putri.kecil17","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-23",true,{"@type":101,"interactionType":102,"userInteractionCount":8},"InteractionCounter",{"@type":103},"ViewAction",{"@type":105,"mainEntity":106},"FAQPage",[107,113,117],{"name":108,"@type":109,"acceptedAnswer":110},"What documentation and monitoring requirements apply to contractors?","Question",{"text":111,"@type":112},"The manual includes a dedicated section for documentation and monitoring, establishing expectations for how contractor activities are recorded and overseen on site.","Answer",{"name":114,"@type":109,"acceptedAnswer":115},"Which safety controls are required before and during hazardous work such as confined space entry?",{"text":116,"@type":112},"It requires a pre-job brief and job hazard analysis, along with specific procedures for confined space entry to manage identified hazards before work begins.",{"name":118,"@type":109,"acceptedAnswer":119},"How does the manual address electrical hazards and arc flash protection?",{"text":120,"@type":112},"It specifies electrical safety and arc flash protection for live electrical work, including minimum approach distances for qualified and non-qualified workers and additional controls for induced voltage and protective grounding.","https://schema.org",{"og:url":83,"og:type":123,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":125,"canonical":83},"index,follow",{"doc_id":127,"site_id":62},646937,1792779251,{"code":4,"msg":5,"data":130},{"doc_id":127,"user_id":131,"nickname":92,"user_avatar":132,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":8,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":138,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144},962094509873,"https://ap-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","Contractor Safety Manual  \nTD&C and Corporate Resources  \nRevision 14 January 2023  \nINDEX  \nPREFACE ........................................................................................................................................................... 4  \nPRIMARY ENVIRONMENTAL,HEALTH AND SAFETY ACTS .................................................................................. 4  \nCONTRACTOR HEALTH AND SAFETY REQUIREMENTS ....................................................................................... 5  \n1 DOCUMENTATION AND MONITORING .......................................................................................................5  \n2 CONTRACTOR’S SAFETY RESPONSIBILITIES ................................................................................................. 7  \n3 CONTRACTOR QUALIFIED ELECTRICAL WORKERS ....................................................................................... 7  \n4 FITNESS FOR DUTY ......................................................................................................................................8  \n5 PRE-JOB BRIEF AND JOB HAZARD ANALYSIS ............................................................................................... 8  \n6 CONFINED SPACE ENTRY ............................................................................................................................. 9  \n7 LOCKOUT/TAGOUT ....................................................................................................................................10  \n8 CONDITION OF POLES ............................................................................................................................... 10  \n9 EXCAVATION AND TRENCHING ................................................................................................................. 11  \n10 SCAFFOLDING ............................................................................................................................................ 11  \n11 PERSONAL PROTECTIVE EQUIPMENT (PPE) .............................................................................................. 11  \n12 RESPIRATORY PROTECTION ....................................................................................................................... 12  \n13 FALL PROTECTION .....................................................................................................................................12  \n14 HOUSEKEEPING .........................................................................................................................................12  \n15 GLOBALLY HARMONIZED SYSTEM (GHS) ...................................................................................................12  \n16 DRIVING COMMERCIAL MOTOR VEHICLES ................................................................................................ 14  \n17 FACILITY ACCESS; DRIVING; MOBILE EQUIPMENT .................................................................................... 15  \n18 AERIAL EQUIPMENT ..................................................................................................................................15  \n19 MATERIALS HANDLING EQUIPMENT.........................................................................................................15  \n20 FIRST AID AND JOBSITE EMERGENCIES .....................................................................................................16  \n21 FIRE PROTECTION ......................................................................................................................................16  \n22 FLAMMABLE LIQUIDS ................................................................................................................................ 16  \n23 ELECTRICAL SAFETY ...................................................................................................................................16  \n24 ARC FLASH PROTECTION-LIVE ELECTRICAL WORK......................","cbCaiqFHdYtji8r8","https://ap.wps.com/l/cbCaiqFHdYtji8r8","pdf",805695,27,"English","# PREFACE\n# PRIMARY ENVIRONMENTAL,HEALTH AND SAFETY ACTS\n# CONTRACTOR HEALTH AND SAFETY REQUIREMENTS\n## 1 DOCUMENTATION AND MONITORING\n## 2 CONTRACTOR’S SAFETY RESPONSIBILITIES\n## 3 CONTRACTOR QUALIFIED ELECTRICAL WORKERS\n## 4 FITNESS FOR DUTY\n## 5 PRE-JOB BRIEF AND JOB HAZARD ANALYSIS\n## 6 CONFINED SPACE ENTRY\n## 7 LOCKOUT/TAGOUT\n## 8 CONDITION OF POLES\n## 9 EXCAVATION AND TRENCHING\n## 10 SCAFFOLDING\n## 11 PERSONAL PROTECTIVE EQUIPMENT (PPE)\n## 12 RESPIRATORY PROTECTION\n## 13 FALL PROTECTION\n## 14 HOUSEKEEPING\n## 15 GLOBALLY HARMONIZED SYSTEM (GHS)\n## 16 DRIVING COMMERCIAL MOTOR VEHICLES\n## 17 FACILITY ACCESS; DRIVING; MOBILE EQUIPMENT\n## 18 AERIAL EQUIPMENT\n## 19 MATERIALS HANDLING EQUIPMENT\n## 20 FIRST AID AND JOBSITE EMERGENCIES\n## 21 FIRE PROTECTION\n## 22 FLAMMABLE LIQUIDS\n## 23 ELECTRICAL SAFETY\n## 24 ARC FLASH PROTECTION-LIVE ELECTRICAL WORK\n## 25 MINIMUM APPROACH DISTANCE (MAD) FOR QUALIFIED ELECTRICAL WORKERS\n## 26 MINIMUM APPROACH DISTANCES (MAD) FOR NON-QUALIFIED WORKERS\n## 27 SUBSTATION AND SWITCHYARD ENTRY AND EXIT\n## 28 INDUCED VOLTAGE\n## 29 PERSONAL PROTECTIVE GROUNDING\n## 30 ASBESTOS\n## 31 TEMPERATURE EXTREMES\n## 32 CAUTION AND DANGER DEMARCATION – BARRIER TAPE\n## 33 REPORTING INCIDENTS, INJURIES AND CLOSE CALLS\n## 34 GENERAL EQUIPMENT SAFETY\n## 35 CONTRACTOR’S ENVIRONMENTAL REQUIREMENTS-ISO 14001\n# Attachment A – Arizona Public Service Company Occupational Safety & Health Administration Qualifications of Contractors and Subcontractors\n# Attachment B – Wood Pole Maintenance Priority Ratings and Tagging\n# Attachment C – Arc Flash Calculations","[{\"question\":\"What documentation and monitoring requirements apply to contractors?\",\"answer\":\"The manual includes a dedicated section for documentation and monitoring, establishing expectations for how contractor activities are recorded and overseen on site.\"},{\"question\":\"Which safety controls are required before and during hazardous work such as confined space entry?\",\"answer\":\"It requires a pre-job brief and job hazard analysis, along with specific procedures for confined space entry to manage identified hazards before work begins.\"},{\"question\":\"How does the manual address electrical hazards and arc flash protection?\",\"answer\":\"It specifies electrical safety and arc flash protection for live electrical work, including minimum approach distances for qualified and non-qualified workers and additional controls for induced voltage and protective grounding.\"}]","Contractor Safety Manual - Revision 14 January 2023 | PDF",1792775862,68]