[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-508562-105":59,"doc-detail-508562-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","constructors-performance-evaluation-system-cpes-implementing-guidelines-for-infrastructure-projects","CONSTRUCTORS’ PERFORMANCE EVALUATION SYSTEM (CPES) - IMPLEMENTING GUIDELINES FOR INFRASTRUCTURE PROJECTS","","Constructors’ Performance Evaluation System (CPES) implementing guidelines establish how procuring entities for Philippine government infrastructure projects must evaluate contractors’ performance. The guidelines cite the Revised IRR of R.A. 9184 and specify required CPES implementation steps, including establishing CPES implementing units and using CPES ratings for pre-qualification, contract award, monitoring, completion certification, policy review, and incentives. The scope defines covered constructor types and joint ventures, and provides key term definitions, including corrective action plan and request, evaluator accreditation, and construction periods.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/constructors-performance-evaluation-system-cpes-implementing-guidelines-for-infrastructure-projects/508562/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/constructors-performance-evaluation-system-cpes-implementing-guidelines-for-infrastructure-projects/508562.png","ImageObject",300,407,{"name":92,"@type":93},"ahduag","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-21","2026-10-05",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",17,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What is the purpose of the CPES guidelines for infrastructure projects?","Question",{"text":113,"@type":114},"The CPES guidelines provide uniform criteria to rate constructors’ performance, build a centralized performance information base, and help ensure infrastructure projects meet specified requirements of project owners.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"Which entities must use the CPES ratings and for what purposes?",{"text":118,"@type":114},"Procuring entities implementing government infrastructure projects must use CPES ratings for purposes including pre-qualification/eligibility screening, awarding contracts, project monitoring and control, issuance of certificates of completion, policy formulation/review, industry planning, and granting incentives/awards.",{"name":120,"@type":111,"acceptedAnswer":121},"What kinds of constructors are covered under the scope of these guidelines?",{"text":122,"@type":114},"The scope covers local constructors licensed and registered with the PCAB, foreign constructors licensed by the PCAB, and joint ventures/consortia licensed by the PCAB.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},508562,1791350471,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":146,"preview_page_count":19,"preview_urls":147},3985747870414,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","CONSTRUCTORS’ PERFORMANCE EVALUATION SYSTEM (CPES)  \nIMPLEMENTING GUIDELINES  \nFOR INFRASTRUCTURE PROJECTS1  \n1. GENERAL  \nSection 12, Annex E of the Revised Implementing Rules and Regulation (IRR) of R.A. 9184 or the Government Procurement Reform Act, requires all procuring entities implementing government infrastructure projects to evaluate the performance of their contractors using the NEDA-approved Constructors Performance Evaluation System (CPES) guidelines for the typeof project being implemented. Section 12, likewise, requires all procuring entities to include in their Projects’ Engineering and Administrative Overhead Cost, the budget for CPES implementation pursuant to NEDA Board Resolution No. 18 (s. 2002); to establish CPES Implementing Units in their respective offices/agencies/corporations; and to use the CPES ratings for the following purposes: a) pre-qualification/eligibility screening; b) awarding of contracts; c) project monitoring & control; d) issuance of Certificate of Completion; e) policy formulation/review; f) industry planning; g) granting of incentives/awards; and in adopting measures to further improve performance of contractors in the prosecution of government projects.  \n2. OBJECTIVES  \nThe CPES was developed in order to:  \n2.1 Establish a uniform set of criteria for rating the performance of constructors;  \n2.2 Develop a centralized base of information on performance rating of constructors for licensing, pre-qualification, quality improvement, and other purposes of government agencies, project owners, financing and insurance companies and other interested parties; and  \n2.3 Contribute in ensuring that infrastructure projects conform with the specified requirements of project owners.  \n3. SCOPE  \nThe guidelines shall be used in the performance evaluation of constructors undertaking government infrastructure projects as follows:  \n3.1 Local constructors licensed by and registered with the Philippine Contractors Accreditation Board (PCAB);  \n3.2 Foreign constructors licensed by the PCAB; and  \n3.3 Joint ventures and consortia licensed by the PCAB.  \n1 Full text of CPES Implementing Guidelines with amendments (in bold and underlined text) as approved by the NEDA INFRACOM under Resolution No. 03 , Series of 2011.  \n4. DEFINITION OF TERMS  \n4.1 CIAP- refers to the Construction Industry Authority of the Philippines, an attached agency of the Department of Trade & Industry created by Presidential Decree (PD) No. 1746 to promote, accelerate, and regulate the growth and development of the construction industry.  \n4.2 Constructor-deemed synonymous with the term builder and hence, any entity including joint venture and consortium licensed by PCAB who undertakes or purports to have the capacity to undertake or submits a bid for infrastructure projects.  \n4.3 Constructors’ Performance Evaluation System (CPES) -a system of grading the performance of a constructor for a specific kind of projects using a set of criteria, approved by the NEDA-INFRACOM.  \n4.4 Constructors’ Performance Evaluator/s (CPE) - an individual or group of evaluators accredited by CIAP tasked to undertake performance evaluation of a constructor’s project using the CPES guidelines and/or evaluation requirements of the construction industry.  \n4.5 Corrective Action Plan (CAP) - is a plan of action proposed by the constructor to the concerned agency’s implementing office which is aimed to correct the non-conformance findings on the project based on the CAR issued by the CPE(s) . The CAP shall include the constructor’s specific actions and timetable to immediately correct the findings subject to the approval by the head of the concerned implementing office or his authorized representative.  \n4.6 Corrective Action Request (CAR) -a request form wherein the CPE records his/her validated finding(s) including corresponding location(s) which do not conform to any of the checklist indicators requiring immediate actions by the constructor.  \n4.7 CPES Imple","cbCaiultD8ovNJU1","https://ap.wps.com/l/cbCaiultD8ovNJU1","pdf",128176,26,"English","# 1. GENERAL\n# 2. OBJECTIVES\n# 3. SCOPE\n# 4. DEFINITION OF TERMS","[{\"question\":\"What is the purpose of the CPES guidelines for infrastructure projects?\",\"answer\":\"The CPES guidelines provide uniform criteria to rate constructors’ performance, build a centralized performance information base, and help ensure infrastructure projects meet specified requirements of project owners.\"},{\"question\":\"Which entities must use the CPES ratings and for what purposes?\",\"answer\":\"Procuring entities implementing government infrastructure projects must use CPES ratings for purposes including pre-qualification/eligibility screening, awarding contracts, project monitoring and control, issuance of certificates of completion, policy formulation/review, industry planning, and granting incentives/awards.\"},{\"question\":\"What kinds of constructors are covered under the scope of these guidelines?\",\"answer\":\"The scope covers local constructors licensed and registered with the PCAB, foreign constructors licensed by the PCAB, and joint ventures/consortia licensed by the PCAB.\"}]","CONSTRUCTORS’ PERFORMANCE EVALUATION SYSTEM (CPES) - IMPLEMENTING GUIDELINES FOR INFRASTRUCTURE PROJECTS | PDF",1791227562,66,[148,152,156,160],{"page_no":8,"url":149,"width":150,"height":151},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/07258ce71256b444a13b03a7d260a20d.webp",983,1389,{"page_no":14,"url":153,"width":154,"height":155},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/f90d6cbd0403eaa00231a74b5421f757.webp",982,1388,{"page_no":81,"url":157,"width":158,"height":159},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/eccf267c3cd1561da1b253f655c65c74.webp",981,1386,{"page_no":19,"url":161,"width":162,"height":163},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/0f003a4c496bf306f819b2ba75d289a7.webp",980,1385]