[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-663218-105":59,"doc-detail-663218-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","construction-standard-specification-section-15810-ductwork-revision-0-january-14-2013","CONSTRUCTION STANDARD SPECIFICATION - SECTION 15810 DUCTWORK - Revision 0 - January 14, 2013","","Specification Section 15810 Ductwork defines minimum requirements for fabrication and installation of HVAC and exhaust ductwork under the contract documents and design drawings. It covers materials and operations including ductwork materials, gauges, pressure classifications, construction, duct liners, filters, dampers, connectors, supports, inspection and testing, and certifications, spanning pressure classes from minus 10\" to plus 10\" water gauge. The standard excludes ductwork for materials handling systems and requires listed items to be followed unless drawings indicate otherwise.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/construction-standard-specification-section-15810-ductwork-revision-0-january-14-2013/663218/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/construction-standard-specification-section-15810-ductwork-revision-0-january-14-2013/663218.png","ImageObject",300,407,{"name":92,"@type":93},"Bulrr","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":29},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What ductwork systems and pressure classes are covered by Section 15810 Ductwork?","Question",{"text":112,"@type":113},"The specification covers heating, ventilating, air conditioning (HVAC), and exhaust systems, including pressure classes from minus 10\" to plus 10\" water gauge (w.g.).","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What scope is excluded from this ductwork specification?",{"text":117,"@type":113},"Ductwork requirements for materials handling systems are excluded from this specification.",{"name":119,"@type":110,"acceptedAnswer":120},"Which ductwork elements must be specified and followed under this section?",{"text":121,"@type":113},"The standard requires specification and compliance for ductwork materials, gauges, pressure classifications, construction, duct liners, filters, dampers, connectors, supports, testing, and certifications, unless drawings note otherwise.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},663218,1793225838,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":29,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":26},5909892115043,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","SAND2013-0667P  \nF A C I L I T I E S M A N A G E M E N T A N D O P E R A T I O N S C E N T E R  \nSpecification Section 15810 Ductwork  \nJanuary 14 , 2013  \nRevision 0  \nSAND  \nThis document has undergone formal review and approval and been reviewed by a Derivative Classifier, and its contents have been deemed unclassified/unlimited release.  \nSandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of  \nLockheed Martin Corporation, forthe U.S. Department of Energy’s National Nuclear Security Administration under contract DE-AC04-94AL85000.  \nChange Log  \n\n| Rev | By | Date | Type | Change Description | Pages Changed |\n| --- | --- | --- | --- | --- | --- |\n| 0 | JG/LEO | 01/14/13 | Subst | Edited and applied FMOC standard spec brand. | All |\n|  |  |  |  |  |  |\n|  |  |  |  |  |  |\n|  |  |  |  |  |  |\n|  |  |  |  |  |  |\n|  |  |  |  |  |  |\n|  |  |  |  |  |  |\n|  |  |  |  |  |  |\n|  |  |  |  |  |  |\n|  |  |  |  |  |  |\n|  |  |  |  |  |  |\n|  |  |  |  |  |  |\n\nCONSTRUCTIONSTANDARD SPECIFICATION  \nSECTION 15810  \nDUCTWORK  \nPage  \nPART 1-GENERAL ..................................................................................................................... 3  \n1.01 SUMMARY ......................................................................................................................... 3  \n1.02 REFERENCES .................................................................................................................... 3  \n1.03 SUBMITTALS .................................................................................................................... 4  \n1.04 QUALITY ASSURANCE ................................................................................................... 6  \n1.05 WARRANTY ...................................................................................................................... 6  \nPART 2-PRODUCTS ................................................................................................................... 6  \n2.01 MATERIALS, GENERAL .................................................................................................. 6  \n2.02 DESIGN AND CONSTRUCTION...................................................................................... 8  \n2.03 DAMPERS......................................................................................................................... 11  \n2.04 HANGERS AND SUPPORTS........................................................................................... 13  \n2.05 SEALANTS ....................................................................................................................... 14  \n2.06 ACCESS DOORS .............................................................................................................. 14  \n2.07 LOUVERS ......................................................................................................................... 15  \nPART 3 – EXECUTION .............................................................................................................. 15  \n3.01 EXAMINATION ............................................................................................................... 15  \n3.02 PREPARATION ................................................................................................................ 16  \n3.03 INSTALLATION .............................................................................................................. 16  \n3.04 GAS FIRED EQUIPMENT ............................................................................................... 17  \n3.05 DUCT LINERS .................................................................................................................. 17  \n3.06 HANGERS AND SUPPORTS FOR VAVAND FAN COIL UNITS................................ 17  \n3.07 CONNECTORS .............................................................................................................","cbCaivskyuYqL4yc","https://ap.wps.com/l/cbCaivskyuYqL4yc","pdf",368270,24,"English","# PART 1-GENERAL\n## 1.01 SUMMARY\n## 1.02 REFERENCES\n## 1.03 SUBMITTALS\n## 1.04 QUALITY ASSURANCE\n## 1.05 WARRANTY\n# PART 2-PRODUCTS\n## 2.01 MATERIALS, GENERAL\n## 2.02 DESIGN AND CONSTRUCTION\n## 2.03 DAMPERS\n## 2.04 HANGERS AND SUPPORTS\n## 2.05 SEALANTS\n## 2.06 ACCESS DOORS\n## 2.07 LOUVERS\n# PART 3 - EXECUTION\n## 3.01 EXAMINATION\n## 3.02 PREPARATION\n## 3.03 INSTALLATION\n## 3.04 GAS FIRED EQUIPMENT\n## 3.05 DUCT LINERS\n## 3.06 HANGERS AND SUPPORTS FOR VAV AND FAN COIL UNITS\n## 3.07 CONNECTORS\n## 3.08 DAMPERS\n## 3.09 ACCESS DOORS\n## 3.10 PLENUMS\n## 3.11 DUCT PENETRATIONS\n## 3.12 LOUVERS\n## 3.13 FILTERS AND GAUGES FOR AIR HANDLING UNITS\n## 3.14 INSPECTION AND TESTING\n## 3.15 CLEANING","[{\"question\":\"What ductwork systems and pressure classes are covered by Section 15810 Ductwork?\",\"answer\":\"The specification covers heating, ventilating, air conditioning (HVAC), and exhaust systems, including pressure classes from minus 10\\\" to plus 10\\\" water gauge (w.g.).\"},{\"question\":\"What scope is excluded from this ductwork specification?\",\"answer\":\"Ductwork requirements for materials handling systems are excluded from this specification.\"},{\"question\":\"Which ductwork elements must be specified and followed under this section?\",\"answer\":\"The standard requires specification and compliance for ductwork materials, gauges, pressure classifications, construction, duct liners, filters, dampers, connectors, supports, testing, and certifications, unless drawings note otherwise.\"}]","CONSTRUCTION STANDARD SPECIFICATION - SECTION 15810 DUCTWORK - Revision 0 - January 14, 2013 | PDF"]