[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-664084-105":59,"doc-detail-664084-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","construction-standard-specification-section-06400-interior-architectural-woodwork-specification","CONSTRUCTION STANDARD SPECIFICATION - SECTION 06400 INTERIOR ARCHITECTURAL WOODWORK - Specification","","Construction Standard Specification Section 06400 establishes requirements for furnishing and installing interior architectural woodwork. It specifies laminate-clad cabinets (plastic-covered casework), thermoset decorative overlays, plastic-laminate and solid-surfacing countertops for wet areas, and associated hardware. The document also defines related sections, references applicable standards and organizations, and includes provisions for submissions, quality assurance, delivery and storage, project conditions, coordination, and definitions. A change log notes updates aligned with guiding principles and LEED-related VOC and formaldehyde limits.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/construction-standard-specification-section-06400-interior-architectural-woodwork-specification/664084/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/construction-standard-specification-section-06400-interior-architectural-woodwork-specification/664084.png","ImageObject",300,407,{"name":92,"@type":93},"Mimi","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-29",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What work does Section 06400 require contractors to provide?","Question",{"text":112,"@type":113},"It requires furnishing and installing interior architectural woodwork as shown on contract documents, including laminate-clad cabinets, thermoset decorative overlays, specified countertop types, and hardware.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Which countertop material is required for wet areas?",{"text":117,"@type":113},"Solid-surfacing material countertops are required for all wet areas, installed where provided with sinks, lavatories, or other plumbing fixtures (e.g., restrooms, kitchens, break areas, and coffee bars).",{"name":119,"@type":110,"acceptedAnswer":120},"Which standards and organizations are referenced in the specification?",{"text":121,"@type":113},"The document references standards and organizations including ALA, ANSI, ASME, ASTM, AWI, BHMA, Federal Specifications, HPVA, NEMA, and SCAQMD (including Rule #1168 for adhesive and sealant application).","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},664084,1793238599,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144},2336477974920,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","F A C I L I T I E S M A N A G E M E N T A N D O P E R A T I O N S C E N T E R  \nSAND2012-5070P  \nSpecification Section 06400 Interior Architectural Woodwork  \nJune 14 , 2012  \nSAND \\#  \nThis document has been through the formal Review and Approval process and been reviewed by Derivative Classiferand its contents have been deemed unclassified/unlimited release.  \nSandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U. S. Department of Energy’s National Nuclear Security Administration under contract DE-AC04-94AL85000 .  \nChange Log  \n\n| By | Date | Type | Change Description | ID |\n| --- | --- | --- | --- | --- |\n| DH/LEO | 6/12/12 | Subst | Incorporated elements of Guiding Principles and LEED® requirements, including consistency in VOC and formaldehyde limit requirements. Edited for general writing improvements. |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n\nJune 14, 2012  \nCONSTRUCTION STANDARD SPECIFICATION  \nSECTION 06400  \nINTERIOR ARCHITECTURAL WOODWORK  \nPage  \nPART 1-GENERAL .....................................................................................................................2  \n1.01 SUMMARY.........................................................................................................................2  \n1.02 REFERENCES ....................................................................................................................2  \n1.03 SUBMITTALS ....................................................................................................................3  \n1.04 QUALITY ASSURANCE...................................................................................................4  \n1.05 DELIVERY, STORAGE, AND HANDLING ....................................................................5  \n1.06 PROJECT CONDITIONS ...................................................................................................5  \n1.07 COORDINATION...............................................................................................................5  \n1.08 DEFINITIONS.....................................................................................................................6  \nPART 2-PRODUCTS ....................................................................................................................6  \n2.01 MATERIALS ......................................................................................................................6  \n2.02 CABINET HARDWARE AND ACCESSORY MATERIALS ..........................................7  \n2.03 INSTALLATION MATERIALS ........................................................................................7  \n2.04 FABRICATION, GENERAL..............................................................................................7  \n2.05 LAMINATE CLAD CABINETS (PLASTIC-COVERED CASEWORK).........................8  \n2.06 COUNTERTOPS.................................................................................................................9  \n3.01 PREPARATION..................................................................................................................9  \n3.02 INSTALLATION .............................................................................................................. 10  \n3.03 COORDINATION............................................................................................................. 10  \n3.04 ADJUSTING AND CLEANING ...................................................................................... 11  \n3.05 PROTECTION .................................................................................................................. 11  \n06400-1  \nINTERIOR ARCHITECTURAL WOODWORK  \nJune 14, 2012  \nCONSTRUCTION STANDARD SPECIFICATION  \nSECTI","cbCaicjQCZdKxmvU","https://ap.wps.com/l/cbCaicjQCZdKxmvU","pdf",77791,15,"English","# PART 1-GENERAL\n## 1.01 SUMMARY\n## 1.02 REFERENCES\n# PART 2-PRODUCTS\n## 2.01 MATERIALS\n## 2.02 CABINET HARDWARE AND ACCESSORY MATERIALS\n## 2.03 INSTALLATION MATERIALS\n## 2.04 FABRICATION, GENERAL\n## 2.05 LAMINATE CLAD CABINETS (PLASTIC-COVERED CASEWORK)\n## 2.06 COUNTERTOPS\n# PART 3-EXECUTION\n## 3.01 PREPARATION\n## 3.02 INSTALLATION\n## 3.03 COORDINATION\n## 3.04 ADJUSTING AND CLEANING\n## 3.05 PROTECTION","[{\"question\":\"What work does Section 06400 require contractors to provide?\",\"answer\":\"It requires furnishing and installing interior architectural woodwork as shown on contract documents, including laminate-clad cabinets, thermoset decorative overlays, specified countertop types, and hardware.\"},{\"question\":\"Which countertop material is required for wet areas?\",\"answer\":\"Solid-surfacing material countertops are required for all wet areas, installed where provided with sinks, lavatories, or other plumbing fixtures (e.g., restrooms, kitchens, break areas, and coffee bars).\"},{\"question\":\"Which standards and organizations are referenced in the specification?\",\"answer\":\"The document references standards and organizations including ALA, ANSI, ASME, ASTM, AWI, BHMA, Federal Specifications, HPVA, NEMA, and SCAQMD (including Rule #1168 for adhesive and sealant application).\"}]","CONSTRUCTION STANDARD SPECIFICATION - SECTION 06400 INTERIOR ARCHITECTURAL WOODWORK - Specification | PDF",38]