[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-664983-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-664983-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","construction-drawings-knysna-municipality-knysna-municipaliteit-plan-no-202220988","CONSTRUCTION DRAWINGS - Knysna Municipality KNYSNA MUNICIPALITEIT PLAN No 2022/20988","","Approved construction drawings for a Knysna Municipality plan (Plan No 2022/20988, approved reference 13610) covering electrical, lighting, and water reticulation elements. The drawings include detailed legends for plug points, lighting types and wattages, intercom and alarm components, electrical fence, garage door motor, and conduit provisions for future fibre optic installations. They also specify water system layout notes for cold and hot water sources, stopcocks, and geyser arrangements, together with general building and trade instructions aligned to SANS 10400 and local authority requirements.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/construction-drawings-knysna-municipality-knysna-municipaliteit-plan-no-202220988/664983/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/construction-drawings-knysna-municipality-knysna-municipaliteit-plan-no-202220988/664983.png","ImageObject",300,407,{"name":42,"@type":43},"Bulrr","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-29",true,{"@type":52,"interactionType":53,"userInteractionCount":30},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"What approval and plan identifiers are stated on the drawings?","Question",{"text":62,"@type":63},"The drawings show Knysna Municipality plan identifiers including Plan No 2022/20988 and an approved reference 13610.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"What types of electrical points and lighting are listed in the legends?",{"text":67,"@type":63},"The legends list multiple plug points (including double, watertight, extractor, periscope), intercom/alarm-related components, and lighting fixtures with specified wattages and locations (down lighters, LED wall and strip lighting, pool light).",{"name":69,"@type":60,"acceptedAnswer":70},"What general construction notes govern the drawings?",{"text":71,"@type":63},"The general notes state that dimensions are in millimeters, drawings must be checked on site, works must comply with National Building Regulations SANS 10400 (including Part O), materials and conduit work must meet approved specifications, and the drawing is not to be scaled.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},664983,1793284365,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,105,110,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},6,"Technology",50,"technology",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":107,"show_sort_weight":108,"slug":109},7,"Healthcare",40,"healthcare",{"id":111,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},8,30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":111,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":30,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":101,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":79,"read_time":143},5909892115043,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","|  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- |\n|  | |  |  |  | \u003Cbr> |  |\n|  |  | Knysna Municipality\u003Cbr>KNYSNA MUNISIPALITEIT PLAN No 2022/20988\u003Cbr>GOEDGEKEUR/APPROVED 13610\u003Cbr>Volgens die NBR. WET No 103 van ~~ 1977 soos gew~~26~~y~~10~~sig  ~~~~ ~~ 7880  3120   According to NBR. ACT No 103 of ~~ 1~~7~~7 as am~~170~~en~~0~~ded  ~~110 530 270 2110 110 5120 270 2850 270  | |  |  |  |\n|  | \u003Cbr>800 2000 800\u003Cbr>\u003Cbr>\u003Cbr>4930\u003Cbr>\u003Cbr>0 900 10\u003Cbr>\u003Cbr>\u003Cbr>800 2000 800\u003Cbr>\u003Cbr>270 3600 270 4930 230 1870 270 3600 270\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>4140 7030 4140\u003Cbr>\u003Cbr>15310\u003Cbr>\u003Cbr>\u003Cbr>DIM at 1300mm above uffl.\u003Cbr>\u003Cbr>Double wall mounted plug, top of socket to be 1250mm above uffl\u003Cbr>\u003Cbr>Double wall mounted plug, top of socket to be 300mm above uffl\u003Cbr>WT\u003Cbr> Double wall mounted watertight plug\u003Cbr>ex Extractor connection plug @ 2100mm\u003Cbr>\u003Cbr> Blank conduiting boxes\u003Cbr> Periscope plug as per specification.\u003Cbr>GD Garage door ceiling mounted motor\u003Cbr>\u003Cbr> TV point aerial\u003Cbr>Shavers plug Telkom point \u003Cbr>N Network point Stove isolator ~~ ~~  ~~ ~~ Power Skirting\u003Cbr>\u003Cbr>(2 x 18 W) 1500 Long 2 tube fluorescent armature with prismatic diffuser suspended from ceiling.\u003Cbr>\u003Cbr> 5 Watt LED Down lighter as per specification\u003Cbr> 20 Watt Compacted Fluorescent pendant light as per specification\u003Cbr>\u003Cbr> (5 Watt x 2 ) Internal LED Wall mounted light\u003Cbr>E (10 Watt x 2 ) External LED Wall mounted light\u003Cbr>sp 50 Watt External LED Wall mounted spotlight\u003Cbr>\u003Cbr>13 Watt Internal compact Fluorecent Up Lighter (wall mounted) as per client\u003Cbr> Starlights (wall mounted) as per client\u003Cbr> LED  LED Strip Lighting\u003Cbr>\u003Cbr>PL Pool light as per client\u003Cbr>\u003Cbr> Foot light\u003Cbr>EF Electrical fence control box.\u003Cbr>\u003Cbr>GC Gate Control Unit\u003Cbr>\u003Cbr>PP Pre-paid Electricity meter\u003Cbr>\u003Cbr>DS Daylight sensor i\u003Cbr>\u003Cbr>Intercom IT Intercom system. AL Alarm HD Hair dryer waterproof plug Main distribution board Sub distribution board UPS Uninterruptible power supply F.O.I\u003Cbr>Sleeve to be installed for future Fibre optic\u003Cbr>installations, sleeve to be as per specialist.\u003Cbr>NOTE: All plugpoints,lightfittingsand cupboards to be demarcated onsite and approved by client/architect prior to installation.\u003Cbr>WATER RETICULATION LEGEND proposed cold water source point. plumber to tap into existing cold water pipes at this point 95mm flexible polyester blanket\u003Cbr>insulation to new\u003Cbr>geyser to achieve R-value of 2.00 municipal water connection and stop cock \u003Cbr> ET  garden tap position 50mm flexible polyester insulation to all new hot water pipes to achieve R-value of 1 proposed cold water reticulation proposed hot water reticulation proposed cold water pipe up proposed cold water pipe down proposed hot water pipe down proposed cold water stopcock proposed hot water stopcock proposed cold tap proposed hot tap \u003Cbr>shower head external mounted heat\u003Cbr>pump as per specialist.  HP  solar geyser on roof with\u003Cbr>geyser in the ceiling\u003Cbr>space as per specialist.\u003Cbr>\u003Cbr>BRICKWORK LEGEND FACE BRICKS |  |  |  | |  |\n|  |  |  |  |  | \u003Cbr>GENERAL NOTES: All dimensions are given in millimeters, unless otherwise specified. All dimensions to be checked on site before construction commences. Contractors to adhere to all local authority's regulations and requirements. Contractors to be a suitably qualified and registered participant in the construction industry as required by Construction Regulation 2014. Drawings to be read in conjunction with the clients OHS (Occupational Health and Safety) file.\u003Cbr>All work to be done in accordance with the National Building Regulations SANS 10400. Before this drawing is priced it is the contractor's responsibility to ensure he is familiar with the site. All trade names quoted may only be substituted by similar, subject to architect's approval. All materials to be installed in strict accordance with manufacturer's specifications. All conduit work tobe SABS approved quality. All light fittings is to be fitted to comply with t","cbCaimdV77TyXa6N","https://ap.wps.com/l/cbCaimdV77TyXa6N","pdf",7064070,"English","# Electrical and lighting legend\n## Water reticulation and geyser arrangements\n## General notes and construction requirements","[{\"question\":\"What approval and plan identifiers are stated on the drawings?\",\"answer\":\"The drawings show Knysna Municipality plan identifiers including Plan No 2022/20988 and an approved reference 13610.\"},{\"question\":\"What types of electrical points and lighting are listed in the legends?\",\"answer\":\"The legends list multiple plug points (including double, watertight, extractor, periscope), intercom/alarm-related components, and lighting fixtures with specified wattages and locations (down lighters, LED wall and strip lighting, pool light).\"},{\"question\":\"What general construction notes govern the drawings?\",\"answer\":\"The general notes state that dimensions are in millimeters, drawings must be checked on site, works must comply with National Building Regulations SANS 10400 (including Part O), materials and conduit work must meet approved specifications, and the drawing is not to be scaled.\"}]","CONSTRUCTION DRAWINGS - Knysna Municipality KNYSNA MUNICIPALITEIT PLAN No 2022/20988 | PDF",15]