[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-505382-105":59,"doc-detail-505382-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","construction-and-demolition-how-to-properly-dispose-of-refrigeration-and-air-conditioning-equipment","Construction and Demolition - How to Properly Dispose of Refrigeration and Air-Conditioning Equipment","","Construction and Demolition factsheet explains EPA requirements under Section 608 of the Clean Air Act for companies disposing of refrigeration and air-conditioning equipment. It focuses on preventing releases of ozone-depleting substances and climate-impact substitutes during demolition, recycling, and destruction activities. The guidance covers legal prohibitions on venting, certification and evacuation standards, recovery equipment and technician certification, recordkeeping for compliance, and procedural steps for sending refrigerant to destruction or reclamation facilities.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/construction-and-demolition-how-to-properly-dispose-of-refrigeration-and-air-conditioning-equipment/505382/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/construction-and-demolition-how-to-properly-dispose-of-refrigeration-and-air-conditioning-equipment/505382.png","ImageObject",300,407,{"name":92,"@type":93},"dhado","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-04","2026-10-04",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",13,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What does U.S. law require for disposal of refrigeration and AC equipment under Section 608?","Question",{"text":113,"@type":114},"EPA regulations under Section 608 prohibit intentionally venting ODS refrigerants and ODS substitutes. They also require refrigerant recovery equipment certification and evacuation requirements to maximize recovery during disposal.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"Why is it illegal to vent refrigerant during disposal?",{"text":118,"@type":114},"Venting is illegal under EPA rules and is harmful to the environment and human health. The factsheet also notes you may be able to earn money by selling recovered refrigerant to an EPA-certified reclaimer.",{"name":120,"@type":111,"acceptedAnswer":121},"How do disposal companies handle refrigerant recovery equipment requirements and technician certification?",{"text":122,"@type":114},"Persons disposing equipment must certify they acquired and properly use EPA-certified recovery equipment tested by an approved organization. The regulations also include certification requirements for technicians disposing refrigeration/AC equipment, with exclusions for small appliances.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},505382,1791267862,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":19,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":52,"preview_page_count":19,"preview_urls":145},5909893218464,"https://ap-avatar.wpscdn.com/davatar_085a072bc5b1113ac321206ff7593b45","Construction and Demolition  \nHow to Properly Dispose of Refrigeration and Air-Conditioning Equipment  \nWhether you are on the job at a construction/demolition site or at a demolition scrapyard or recycling facility, you are likely to encounter refrigeration and air-conditioning (AC) equipment. Refrigeration/AC equipment has historically used refrigerants and/or insulating foam, such as chlorofluorocarbons (CFCs) and hydrochlorofluorocarbons (HCFCs), which deplete the stratospheric ozone layer and contribute to global climate change. Newer refrigeration/AC equipment is likely to contain hydrofluorocarbons (HFCs), which are used as ozone-friendly substitutes for CFCs and HCFCs but still contribute to climate change. The types of CFC, HCFC, and HFC refrigerants commonly used in refrigeration/AC equipment are shown in Box 1.  \nThis factsheet outlines the requirements established by the U.S. Environmental Protection Agency (EPA) regarding refrigerants, as well as tips on best practices for handling refrigerants and foams, to ensure that emissions of  \nozone-depleting substances (ODS) and their substitutes are minimized during the disposal of refrigeration/AC equipment by companies in the demolition/recycling industry.  \nWhat is Required by Law?  \nUnder Section 608 of the Clean Air Act (CAA), EPA has established regulations (40 CFR Part 82, Subparts A and F) that are relevant to the disposal of refrigeration/AC equipment. These regulations specify:  \n1. A prohibition on intentionally venting ODS refrigerants and ODS substitutes into the atmosphere while disposing of refrigeration/AC equipment;  \n2. Certification requirements for refrigerant recovery equipment, as well as refrigerant evacuation requirements, to maximize recovery of ODS during the disposal of refrigeration/AC equipment;  \n3. Certification requirements for technicians disposing of refrigeration/AC equipment, excluding small appliances (see Box 4 on page 3) ;  \nBox 1. What Types of Refrigerants Are Typically Contained in Refrigeration/AC Equipment in the U.S.?  \nThe refrigerants commonly found in refrigeration/AC equipment, as well as their approximate charge sizes, are listed in the table below. Actual equipment charge size varies based on equipment type and model. As shown, a household refrigerator typically contains  \n0.5 pounds of refrigerant, while a building chiller may contain over  \n1,000 pounds.  \nTypical Refrigerants and Charge Sizes Commonly Used in Refrigeration/AC Equipment  \nEquipment Type  \nChillers  \nCold Storage  \nCommercial Refrigeration  \nDehumidifiers Domestic Refrigerators & Freezers  \nIce Makers  \nIndustrial Refrigeration  \nPTAC/PTHP Unitary AC Window AC  \nCommon Refrigerants  \nCFC-11, CFC-12, HCFC-22, HCFC- 123, HFC-134a, R-407C** CFC-12, R-502*, HCFC-22, R-404ACFC-12, HCFC-22, R-404A, R-507A**  \nHCFC-22, HFC-134a CFC-12, HFC-134a  \nCFC-12, HFC-134a  \nCFC-11, CFC-12, HCFC-22, HCFC- 123, HFC-134a, R-404A** HCFC-22, R-410A**  \nHCFC-22, R-410A  \nHCFC-22, R-407C/410A  \nCharge Sizes (lb)  \n570 – 1,150  \n0.017-0.019/ft2 1,320 – 1,980  \n0.4-0.5 0.51  \n5.5 – 6.6  \n1,340 – 8,110  \n1.3 – 1.5  \n7.5 – 9.5  \n1.1 – 1.3  \n*Refrigerant blend containing HCFC-22 and CFC-115  \n** HFC blend  \n4. Safe disposal requirements for small appliances to ensure removal of refrigerants from goods that enter the waste stream with the refrigerant charge intact;  \n5. Recordkeeping requirements for persons disposing of refrigeration/AC equipment to certify to EPA that they have acquired refrigerant recovery equipment and are complying with the rule; and  \n6. Procedural requirements for sending refrigerant to a destruction or reclamation facility.  \nBox 2. Why Shouldn’t I Just Vent Refrigerant?  \n1. It’s illegal;  \n2. It’s harmful to the environment and human health; and  \n3. You can earn money by selling recovered refrigerant to an EPA-certified refrigerant reclaimer.  \nHow Do I Recover Refrigerant?  \nSection 608 of the CAA prohibits individuals from intentionally venting refrige","cbCaikxvUqBNKKYj","https://ap.wps.com/l/cbCaikxvUqBNKKYj","pdf",941321,"English","# What is Required by Law?\n## Clean Air Act Section 608 and EPA regulations\n## Prohibitions and certification requirements\n# Box 1: Types of Refrigerants and Charge Sizes\n# Box 2: Why Shouldn’t I Just Vent Refrigerant?\n# How Do I Recover Refrigerant?\n## Venting prohibition and de minimis exceptions\n## Evacuation levels and recovery equipment requirements\n# Box 3: EPA-Certified Recovery Equipment\n## Approval bodies and certification sources","[{\"question\":\"What does U.S. law require for disposal of refrigeration and AC equipment under Section 608?\",\"answer\":\"EPA regulations under Section 608 prohibit intentionally venting ODS refrigerants and ODS substitutes. They also require refrigerant recovery equipment certification and evacuation requirements to maximize recovery during disposal.\"},{\"question\":\"Why is it illegal to vent refrigerant during disposal?\",\"answer\":\"Venting is illegal under EPA rules and is harmful to the environment and human health. The factsheet also notes you may be able to earn money by selling recovered refrigerant to an EPA-certified reclaimer.\"},{\"question\":\"How do disposal companies handle refrigerant recovery equipment requirements and technician certification?\",\"answer\":\"Persons disposing equipment must certify they acquired and properly use EPA-certified recovery equipment tested by an approved organization. The regulations also include certification requirements for technicians disposing refrigeration/AC equipment, with exclusions for small appliances.\"}]","Construction and Demolition - How to Properly Dispose of Refrigeration and Air-Conditioning Equipment | PDF",1791146178,[146,150,154,158],{"page_no":8,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/6d48f4123a3a70c3761ca548a5b837fe.webp",983,1272,{"page_no":14,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/15213b9c95e43918d059b9d4a277740b.webp",982,1270,{"page_no":81,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/db8318816061252f80a85c56ebe40ec8.webp",981,1269,{"page_no":19,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/7b95545808198dc64ee770909d016718.webp",980,1268]