[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-563030-105":59,"doc-detail-563030-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","conquer-type-r60-series-polymeric-positive-temperature-coefficient-pptc-resettable-fuse","CONQUER - Type R60 Series Polymeric Positive Temperature Coefficient (PPTC) - Resettable Fuse","","CONQUER Type R60 Series polymeric positive temperature coefficient (PPTC) resettable fuse specification sheet provides agency file numbers and key electrical and environmental ratings. It lists operating/storage temperature range (-40°C to +85°C), maximum device surface temperature in tripped state (125°C), and aging and durability conditions including passive aging and humidity aging with typical resistance change tolerances. Thermal shock, vibration, material composition per R60 model range, packaging formats, and cautions for operation beyond specified limits are included. A model-by-model electrical table supports parameters such as Vmax, Imax, hold/trip currents, Pd max, time-to-trip, and resistance limits with UL and TUV approvals.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/conquer-type-r60-series-polymeric-positive-temperature-coefficient-pptc-resettable-fuse/563030/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/conquer-type-r60-series-polymeric-positive-temperature-coefficient-pptc-resettable-fuse/563030.png","ImageObject",300,407,{"name":92,"@type":93},"dabgoudw","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-14","2026-10-12",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What are the operating/storage and tripped-state surface temperature limits for the R60 series fuse?","Question",{"text":112,"@type":113},"The operating/storage temperature range is -40°C to +85°C. The maximum device surface temperature in the tripped state is 125°C.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What aging and environmental tests are specified?",{"text":117,"@type":113},"Passive aging and humidity aging are specified at +85°C for 1000 hours with ±5% typical resistance change tolerance. Thermal shock from +85°C to -40°C allows ±10% typical resistance change, and vibration follows MIL-STD-202C, Method 201 with no change.",{"name":119,"@type":110,"acceptedAnswer":120},"Where can I find model-specific electrical parameters for different R60 ratings?",{"text":121,"@type":113},"A model table lists values by R60-010, R60-017, R60-020, up through R60-375, including Vmax, Imax, Ihold, Itrip/Time To Trip, Pd max, and resistance limits (Rimin/max and R1max), along with UL and TUV markings.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},563030,1792016943,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":8,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":81},3985747860484,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","|  | CONQUER\u003Cbr>Resettable Fuse |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  | |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| Type R60 Series  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| Polymeric Positive Temperature Coefficient\u003Cbr>(PPTC) |  |  |  |  |  |  |  |  |  | |  |  |  | |  | |  |  |  |  |\n| |  | |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| Agency File Number\u003Cbr>UL E201504/E319079 TUV 43486\u003Cbr>Electrical Characteristic\u003Cbr>Operating/Storage Temperature\u003Cbr>-40°C to +85°C\u003Cbr>Maximum Device Surface Temperature\u003Cbr>In Tripped State 125°C\u003Cbr>Passive Aging\u003Cbr>+85°C, 1000Hours, ±5% Typical Resistance Change\u003Cbr>Humidity Aging\u003Cbr>+85°C, 85%R. H. , 1000Hours, ±5% Typical Resistance Change\u003Cbr>Thermal Shock:\u003Cbr>+85°C to-40°C, ±10% Typical Resistance Change\u003Cbr>Vibration\u003Cbr>MIL-STD-202C, Method 201, No Change\u003Cbr>Physical Characteristic |  |  |  |  |  |  |  | Physical Dimension (Unit: mm/inch)\u003Cbr>|  |  |  |  |  |  |  |  |  |  |  |  |\n| Material\u003Cbr>R60-010: Tin-plated nickel-copper alloy, 0.205mm2 (24AWG), ø0.51mm(0 .020 in) . R60-017~040: Tin-plated copper-clad steel, 0.205mm2 (24AWG), ø0.51mm(0 .020 in) .\u003Cbr>R60-050~090: Tin-plated copper , 0.205mm2 (24AWG), ø0.51mm(0 .020 in) . R60-110 ~ 375: Tin-plated copper , 0.52mm2 (20AWG), ø0.81mm(0 .032 in) .\u003Cbr>Electrical Properties |  |  |  |  |  |  |  |  |  | Packaging\u003Cbr>In Bulk: 500 pcs per box.\u003Cbr>On Tap: Ammo pack\u003Cbr>R60-010~R60-090 3000 PCS, R60-110~R60-185 1500 PCS\u003Cbr>R60-017 2500 PCS, R60-250~R60-375 - |  |  |  |  |  |  |  |  |  |  |\n|  | Model |  | Vmax\u003Cbr>(Vdc) | Imax\u003Cbr>(A) | Ihold\u003Cbr>@25℃\u003Cbr>(A) | @I t2rip5℃\u003Cbr>(A) | Pd\u003Cbr>Max.\u003Cbr>(W) |  | Maxumum Time To Trip |  |  | Resistance |  |  | Agency Approval |  |  |  | 62 |  |\n|  |  |  |  |  |  |  |  |  | Current\u003Cbr>(A) |  | Time\u003Cbr>(Sec) | Rimin (Ω) | Rimax (Ω) | R1max (Ω) | UL |  | TUV-PS |  |  |  |\n|  | R60-010 |  | 60 | 40 | 0.10 | 0.20 | 0.38 |  | 0.50 |  | 4.0 | 2.50 | 4.50 | 7.50 | * |  | * |  |  |  |\n|  | R60-017 |  | 60 | 40 | 0.17 | 0.34 | 0.48 |  | 0.85 |  | 3.0 | 2.50 | 5.21 | 8.00 | * |  | * |  |  |  |\n|  | R60-020 |  | 60 | 40 | 0.20 | 0.40 | 0.41 |  | 1.00 |  | 2.2 | 1.25 | 2.75 | 4.40 | * |  | * |  |  |  |\n|  | R60-025 |  | 60 | 40 | 0.25 | 0.50 | 0.45 |  | 1.25 |  | 2.5 | 0.65 | 1.95 | 3.00 | * |  | * |  |  |  |\n|  | R60-030 |  | 60 | 40 | 0.30 | 0.60 | 0.49 |  | 1.50 |  | 3.0 | 0.45 | 1.33 | 2.10 | * |  | * |  |  |  |\n|  | R60-040 |  | 60 | 40 | 0.40 | 0.80 | 0.56 |  | 2.00 |  | 3.8 | 0.40 | 0.86 | 1.29 | * |  | * |  |  |  |\n|  | R60-050 |  | 60 | 40 | 0.50 | 1.00 | 0.77 |  | 2.50 |  | 4.0 | 0.35 | 0.77 | 1.17 | * |  | * |  |  |  |\n|  | R60-065 |  | 60 | 40 | 0.65 | 1.30 | 0.88 |  | 3.25 |  | 5.3 | 0.25 | 0.48 | 0.72 | * |  | * |  |  |  |\n|  | R60-075 |  | 60 | 40 | 0.75 | 1.50 | 0.92 |  | 3.75 |  | 6.3 | 0.20 | 0.40 | 0.60 | * |  | * |  |  |  |\n|  | R60-090 |  | 60 | 40 | 0.90 | 1.80 | 0.99 |  | 4.50 |  | 7.2 | 0.15 | 0.31 | 0.47 | * |  | * |  |  |  |\n|  | R60-110 |  | 60 | 40 | 1.10 | 2.20 | 1.50 |  | 5.50 |  | 8.2 | 0.13 | 0.25 | 0.38 | * |  | * |  |  |  |\n|  | R60-135 |  | 60 | 40 | 1.35 | 2.70 | 1.70 |  | 6.75 |  | 9.6 | 0.10 | 0.19 | 0.30 | * |  | * |  |  |  |\n|  | R60-160 |  | 60 | 40 | 1.60 | 3.20 | 1.90 |  | 8.00 |  | 11.4 | 0.07 | 0.14 | 0.22 | * |  | * |  | Conquer E lectronics Co. ., Ltd  |  |\n|  | R60-185 |  | 60 | 40 | 1.85 | 3.70 | 2.10 |  | 9.25 |  | 12.6 | 0.06 | 0.12 | 0.19 | * |  | * |  |  |  |\n|  | R60-250 |  | 60 | 40 | 2.50 | 5.00 | 2.50 |  | 12.50 |  | 15.6 | 0.04 | 0.08 | 0.13 | * |  | * |  |  |  |\n|  | R60-300 |  | 60 | 40 | 3.00 | 6.00 | 2.80 |  | 15.00 |  | 19.8 | 0.03 | 0.06 | 0.10 | * |  | * |  |  |  |\n|  | R60-375 |  | 60 | 40 | 3.75 | 7.50 | 3.20 |  | 18.75 |  | 24.0 | 0.02 | 0.05 | 0.08 | * |  | * |  |  |  |\n|  | Ihold = Hold Current : maximum current device will sustain for 4 hours without trippin","cbCaifC3Vprvsrmz","https://ap.wps.com/l/cbCaifC3Vprvsrmz","pdf",152182,"English","# Type R60 Series - Polymeric PPTC Resettable Fuse\n## Agency approvals and file numbers\n## Electrical characteristics and temperature ratings\n## Environmental reliability tests\n## Materials and packaging\n## Model parameter table (R60-010 to R60-375)\n## Definitions and operating caution","[{\"question\":\"What are the operating/storage and tripped-state surface temperature limits for the R60 series fuse?\",\"answer\":\"The operating/storage temperature range is -40°C to +85°C. The maximum device surface temperature in the tripped state is 125°C.\"},{\"question\":\"What aging and environmental tests are specified?\",\"answer\":\"Passive aging and humidity aging are specified at +85°C for 1000 hours with ±5% typical resistance change tolerance. Thermal shock from +85°C to -40°C allows ±10% typical resistance change, and vibration follows MIL-STD-202C, Method 201 with no change.\"},{\"question\":\"Where can I find model-specific electrical parameters for different R60 ratings?\",\"answer\":\"A model table lists values by R60-010, R60-017, R60-020, up through R60-375, including Vmax, Imax, Ihold, Itrip/Time To Trip, Pd max, and resistance limits (Rimin/max and R1max), along with UL and TUV markings.\"}]","CONQUER - Type R60 Series Polymeric Positive Temperature Coefficient (PPTC) - Resettable Fuse | PDF",1791810369]