[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-663558-105":59,"doc-detail-663558-en":129},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":122,"head_meta":124,"extra_data":126,"updated_unix":128},105,"en","composite-elevated-tank-technical-design-drawings","Composite Elevated Tank - Technical Design Drawings","","This document provides detailed technical engineering drawings and design specifications for a composite elevated water storage tank. It includes structural elevation views, orientation plans, and key component details such as access ladders, platforms, inlet/outlet piping, and ventilation systems. The documentation outlines essential construction considerations, including foundation requirements, OSHA-compliant safety standards for ladders, and electrical schematic specifications. It serves as a comprehensive reference for site installation, component configuration, and maintenance planning for water utility infrastructure.",{"@graph":69,"@context":121},[70,84,104],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":57,"@type":76,"position":81},"https://docshare.wps.com/document/general/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/composite-elevated-tank-technical-design-drawings/663558/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":98,"encodingFormat":97,"isAccessibleForFree":99,"interactionStatistic":100},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/composite-elevated-tank-technical-design-drawings/663558.png","ImageObject",300,407,{"name":92,"@type":93},"supergirl","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-28",true,{"@type":101,"interactionType":102,"userInteractionCount":4},"InteractionCounter",{"@type":103},"ViewAction",{"@type":105,"mainEntity":106},"FAQPage",[107,113,117],{"name":108,"@type":109,"acceptedAnswer":110},"What are the primary structural components of the composite elevated tank?","Question",{"text":111,"@type":112},"The tank design features a concrete dome with a steel liner, an access tube, interior and exterior painters' rails, overflow pipes, and a multi-level ladder system with pass-thru platforms for maintenance access.","Answer",{"name":114,"@type":109,"acceptedAnswer":115},"How is the foundation size determined for the composite elevated tank?",{"text":116,"@type":112},"According to the general notes, the concrete support structure diameter and foundation dimensions must be determined by the tank contractor based on specified soil bearing capacities and professional soil report recommendations.",{"name":118,"@type":109,"acceptedAnswer":119},"What safety requirements are specified for the internal ladders?",{"text":120,"@type":112},"All ladders and landings installed inside the concrete support structure must be hot-dipped galvanized, and a galvanized ladder safety device meeting OSHA standards must be provided when required.","https://schema.org",{"og:url":83,"og:type":123,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":125,"canonical":83},"index,follow",{"doc_id":127,"site_id":62},663558,1793229283,{"code":4,"msg":5,"data":130},{"doc_id":127,"user_id":131,"nickname":92,"user_avatar":132,"doc_module":4,"category_id":56,"category_name":57,"doc_title":65,"doc_description":67,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":4,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":81,"language":138,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":139,"faqs":140,"seo_title":141,"seo_description":67,"update_tm":128,"read_time":24},962088121634,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","10  \n\n|  |  |  |\n| --- | --- | --- |\n| ELEVATION  \u003Cbr>ELEVATED WATER STORAGE TANK  \u003Cbr>COMPOSITE ELEVATED TANK  \u003Cbr>GALLON CAPACITY   |  |  |\n| DATE  \u003Cbr>BY_  \u003Cbr>DATE  \u003Cbr>CHKD_   | PROJECT NO.   |  |\n|  | DWG.   | REV.   |\n\nN90′OA38-73-130  \n9D1102 REV 0  \nN90'SA38-d9-130  \nELEVATION  \n(N.T.S.)  \n| AZIMUTH   | DESCRIPTION   |\n| --- | --- |\n|  |  |\n|  | NORTH ARROW   |\n|  | ELECTRIC ENTRANCE   |\n|  | OVERFL0W SPLASH PAD   |\n|  | PERSONNEL D00R   |\n|  | INLET/OUTLET PIPE   |\n|  | SIGN/LOGO   |\n|  |  |\n\n#### 180 DEG\n\n## ORIENTATION PLAN\n\nGENERAL NOTES    \n#### 1.CONCRETE SUPPORT STRUCTURE DIAMETER AND DIMENSIONS OF FOUNDATION SHALL BEDETERMINED BY THE TANK CONTRACTOR BASED UPON THE SOIL BEARINGSPECIFIED AND THE RECOMMENDATIONS IN THE SOIL REPORT.\n\n2A GALVANIZED LADDER SAFETY DEVCE MEETING OSHA STANDARDS SHALL BEPROVDED WHEN REQUIRED.  \n3.SEE SPECIFICATIONS FOR OPTIONAL ACCESSORIES AND ALTERNATE ITEMS.  \n4.ALL LADDERS,LANDINGS,AND ASSOCIATED COMPONENTS INSTALLED INSIDETHE CONCRETE SUPPORT STRUCTURE SHALL BE HOT-DIPPED GALVANIZED.  \n\n|  |  |  |\n| --- | --- | --- |\n| GENERAL PLAN  \u003Cbr>ELEVATED WATER STORAGE TANK  \u003Cbr>COMPOSITE ELEVATED TANK  \u003Cbr>GALLON CAPACITY   |  |  |\n| DATE  \u003Cbr>BY_   | PROJECT NO.   |  |\n| DATE  \u003Cbr>CHKD_   | DWG.   | REV.   |\n\n9D1100 REV5  \n### INLET/OUTLET PIPE WTH BAR OVER AND REMOVEABLE SILT STOP  \n\nSIGN OR LOGO  \nMINIMUM 4 SPARE CIRCUITS  \n①ONE AT LOAD CENTER 48”ABOVE FL₀0R  \n# ②0NE ABOVE TOP PLATFORM③ONE IN ACCESS TUBE NEAR TOP HATCHELECTRICAL SCHEMATIC BURIED THRUST BLOCK DETAIL(N.T.S.) \n\n|  |  |  |\n| --- | --- | --- |\n| DETAILS  \u003Cbr>ELEVATED WATER STORAGE TANK  \u003Cbr>COMPOSITE ELEVATED TANK  \u003Cbr>GALLON CAPACITY   |  |  |\n| DATE  \u003Cbr>BY_   | PROJECT NO.   |  |\n| DATE  \u003Cbr>CHKD_   | DWG.   | REV.   |\n\n### TYPICAL PLAN OF LADDERAND NTERMEDIATE PLATFORM\n\nCET_Dtl05.DGN  \n9D101 REV 5","cbCaioo60gggq8nq","https://ap.wps.com/l/cbCaioo60gggq8nq","pdf",247117,"English","# Structural Design and Elevations\n## Tank Components and Access Systems\n# Orientation and Layout\n## Site Plan and Azimuth Specifications\n# Technical Details and Specifications\n## Foundation and Electrical Requirements","[{\"question\":\"What are the primary structural components of the composite elevated tank?\",\"answer\":\"The tank design features a concrete dome with a steel liner, an access tube, interior and exterior painters' rails, overflow pipes, and a multi-level ladder system with pass-thru platforms for maintenance access.\"},{\"question\":\"How is the foundation size determined for the composite elevated tank?\",\"answer\":\"According to the general notes, the concrete support structure diameter and foundation dimensions must be determined by the tank contractor based on specified soil bearing capacities and professional soil report recommendations.\"},{\"question\":\"What safety requirements are specified for the internal ladders?\",\"answer\":\"All ladders and landings installed inside the concrete support structure must be hot-dipped galvanized, and a galvanized ladder safety device meeting OSHA standards must be provided when required.\"}]","Composite Elevated Tank - Technical Design Drawings | PDF"]