[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-514265-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-514265-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","compliance-inspections-for-existing-subsurface-sewage-treatment-systems-fact-sheet-wq-wwists4-30-september-2008","Compliance Inspections for Existing Subsurface Sewage Treatment Systems - Fact Sheet - wq-wwists4-30 - September 2008","","Compliance Inspections for Existing Subsurface Sewage Treatment Systems explains how compliance inspections evaluate an existing SSTS to determine whether a Certificate of Compliance (COC) can be issued or a Notice of Non-compliance (NON) is required. It defines what COC and NON mean, including validity and failure designations, outlines who may conduct inspections and what forms are required, and summarizes key compliance criteria such as public health protection, groundwater protection, permit-based operation, and vertical separation standards with SWF and pre-/post-1996 distinctions.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/healthcare/","Healthcare",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/compliance-inspections-for-existing-subsurface-sewage-treatment-systems-fact-sheet-wq-wwists4-30-september-2008/514265/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/compliance-inspections-for-existing-subsurface-sewage-treatment-systems-fact-sheet-wq-wwists4-30-september-2008/514265.png","ImageObject",300,407,{"name":42,"@type":43},"Stanley","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-10","2026-10-06",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",8,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What is the purpose of a compliance inspection for an existing SSTS?","Question",{"text":63,"@type":64},"A compliance inspection evaluates, investigates, or inspects the system to issue either a Certificate of Compliance (COC) or a Notice of Non-compliance (NON).","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How do the COC and the NON differ?",{"text":68,"@type":64},"A COC certifies the system complies with state requirements at the time of inspection and is valid for three years from issuance. A NON indicates the system is not in compliance and specifies failure types such as an Imminent Threat to Public Health or Safety or Failing to Protect Groundwater.",{"name":70,"@type":61,"acceptedAnswer":71},"Who may conduct a compliance inspection and what must be submitted after inspection?",{"text":72,"@type":64},"Inspections must be conducted by MPCA-certified inspectors or qualified employees with appropriate licenses, or by registered state/county/city/township employees. Inspectors must use the MPCA Existing SSTS Compliance Inspection form and submit completed COCs or NONs to the system owner or agent and the LGU within 15 business days.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},514265,1791587050,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,110,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":108,"slug":109},7,40,"healthcare",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":107,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":26,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":143,"read_time":97,"preview_page_count":4},2336477405376,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","Water Quality/Wastewater \\#4 .30 • September 2008  \nThis fact sheet provides information  \nfor homeowners and realtors on  \nCompliance Inspections for existing Subsurface Sewage Treatment System (SSTS) .  \nWhat is a compliance inspection?  \nA compliance inspection is an evaluation, investigation, inspection or other such process conducted for the purpose of issuing a Certificate of Compliance (COC) or Notice of Non-compliance (NON) .  \nWhat are a COC and a NON?  \nThe COC certifies a system is in compliance with state requirements at the time of the inspection. The COC does not guarantee future hydraulic performance, especially if the use changes or the flow increases over the amounts used by the current occupants.  \nFor an existing SSTS, the COC is valid for three years from the date of issuance.  \nThe NON gives notice a system fails to bein compliance with state requirements atthe time of inspection. There are two types of failing designations, an Imminent Threat to Public Health or Safety and a Failing to Protect Ground water. The NON must also indicate the time frame for upgrade, repair, or replacement as set in the local ordinance.  \nBoth documents must include a signed, certified statement stating the person conducting the inspection completed the work in accordance with applicable regulations.  \nIs a disclosure the same as a compliance inspection?  \nNo. A septic system disclosure is different than a compliance inspection. A disclosure describes, to the best ofthe property owner’s knowledge, the location of a SSTSon the property and what condition it is in. A compliance inspection is conducted by a specifically trained and licensed individual to determine if the SSTS is in compliance with state regulations. A disclosure is not a compliance inspection and cannot be used as a substitute.  \nWhen are compliance inspections required?  \nWhile state law does not require an inspection at property transfer, many Local Government Units (LGUs) have ordinances requiring this. LGUs are Counties, Townships, and Cities.  \nThe LGU may also require a compliance inspection when complaints are received, as part of area surveys, or for lot splits. Compliance inspections can also be required upon request by the purchaser of a property, the mortgage lender, or real estate agent.  \nwq-wwists4-30  \nWho can conduct a compliance inspection?  \nCompliance inspections must be conducted by:  \n• Minnesota Pollution Control Agency (MPCA) -Certified Inspector, Advanced Inspector, or Qualified Employees of a business with a MPCA Inspector or Advanced Inspector license; or  \n• State, county, city, or township employees with MPCA Inspector or Advanced Inspector registration.  \nWhat forms must an inspector use?  \nThe MPCA’s Existing SSTS Compliance Inspection form must be used. Additional forms, if required by the LGU, may also be attached. The inspector must submit COCs or NONs to the system owner or owner’s agent and the LGU within 15 business days after the date of inspection.  \nWhat are the compliance criteria for an existing SSTS?  \n• must be protective of public health and safety  \n• must be protective of ground water  \n• must be operated, meet performance standards, and be managed according to its operating permit  \n• must meet vertical separation requirements applicable to the date the system was constructed, its location, or the facility it serves  \no if built after March 31, 1996, or in a shorelandarea, well head protection area, or serving food, beverage, or lodging establishments (SWF), a three-foot vertical separation distance as measured outside the area of system influence in an area of similar soil is required  \n• the local ordinance may allow up to a 15 percent reduction in the vertical separation distance to account for settling of sand or soil, normal variation of measurements, and interpretations ofthe limiting layer conditions  \no if built before April 1, 1996, or in areas that are not SWF, a two vertical separation or a vertical separat","cbCaijSrAAwbDq6G","https://ap.wps.com/l/cbCaijSrAAwbDq6G","pdf",48535,"English","# What is a compliance inspection?\n# What are a COC and a NON?\n# Is a disclosure the same as a compliance inspection?\n# When are compliance inspections required?\n# Who can conduct a compliance inspection?\n# What forms must an inspector use?\n# What are the compliance criteria for an existing SSTS?\n# What is the upgrade time frame for a failing SSTS?\n# Where do I find more information?","[{\"question\":\"What is the purpose of a compliance inspection for an existing SSTS?\",\"answer\":\"A compliance inspection evaluates, investigates, or inspects the system to issue either a Certificate of Compliance (COC) or a Notice of Non-compliance (NON).\"},{\"question\":\"How do the COC and the NON differ?\",\"answer\":\"A COC certifies the system complies with state requirements at the time of inspection and is valid for three years from issuance. A NON indicates the system is not in compliance and specifies failure types such as an Imminent Threat to Public Health or Safety or Failing to Protect Groundwater.\"},{\"question\":\"Who may conduct a compliance inspection and what must be submitted after inspection?\",\"answer\":\"Inspections must be conducted by MPCA-certified inspectors or qualified employees with appropriate licenses, or by registered state/county/city/township employees. Inspectors must use the MPCA Existing SSTS Compliance Inspection form and submit completed COCs or NONs to the system owner or agent and the LGU within 15 business days.\"}]","Compliance Inspections for Existing Subsurface Sewage Treatment Systems - Fact Sheet - wq-wwists4-30 - September 2008 | PDF",1791298057]