[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-460274-105":59,"doc-detail-460274-en":134},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":127,"head_meta":129,"extra_data":131,"updated_unix":133},105,"en","comparative-evaluation-of-resorbable-versus-titanium-fixation-systems-in-mandibular-fracture-management","Comparative Evaluation of Resorbable Versus Titanium Fixation Systems in Mandibular Fracture Management","","Titanium plates are a longstanding standard for mandibular fracture fixation, yet their palpability, imaging artifacts, and the possibility of hardware removal have driven interest in resorbable fixation systems. This prospective randomized clinical trial compared resorbable poly-L-lactic acid (PLLA) with titanium miniplates and screws in 60 patients. Outcomes assessed at 1 week, 1 month, and 3 months included stability, infection, wound healing, and neurosensory deficits. Results showed similar fracture union and complication rates, while operative time was longer with resorbable fixation.",{"@graph":69,"@context":126},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/comparative-evaluation-of-resorbable-versus-titanium-fixation-systems-in-mandibular-fracture-management/460274/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/comparative-evaluation-of-resorbable-versus-titanium-fixation-systems-in-mandibular-fracture-management/460274.png","ImageObject",300,407,{"name":92,"@type":93},"A glass of water","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-29","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":44},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118,122],{"name":109,"@type":110,"acceptedAnswer":111},"What clinical outcomes were compared between resorbable and titanium fixation systems?","Question",{"text":112,"@type":113},"The trial compared stability, infection, wound healing, and neurosensory deficits at 1 week, 1 month, and 3 months after surgery.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How was the study designed and how many patients were included?",{"text":117,"@type":113},"A prospective randomized clinical trial enrolled 60 patients with isolated mandibular fractures, assigning 30 to titanium fixation and 30 to resorbable PLLA fixation.",{"name":119,"@type":110,"acceptedAnswer":120},"Were fracture union and infection rates different between the two fixation methods?",{"text":121,"@type":113},"Fracture union rates at 3 months were similar (titanium 96.7% vs resorbable 93.3%, P = 0.56), and infection rates showed no significant difference (P = 0.65).",{"name":123,"@type":110,"acceptedAnswer":124},"What key difference did the study find regarding operative time?",{"text":125,"@type":113},"Mean operative time was significantly higher in the resorbable group (92.4 ± 12.6 min) compared with the titanium group (76.8 ± 10.9 min; P \u003C 0.001).","https://schema.org",{"og:url":83,"og:type":128,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":130,"canonical":83},"index,follow",{"doc_id":132,"site_id":62},460274,1790758118,{"code":4,"msg":5,"data":135},{"doc_id":132,"user_id":136,"nickname":92,"user_avatar":137,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":138,"file_id":139,"file_url":140,"file_type":141,"file_size":142,"view_count":44,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":81,"language":143,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":144,"faqs":145,"seo_title":146,"seo_description":67,"update_tm":133,"read_time":39,"preview_page_count":81,"preview_urls":147},962090760832,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","Original Research  \nComparative Evaluation of Resorbable Versus Titanium Fixation Systems in Mandibular Fracture Management  \nKanishka Guru1, Padmanabha Kumar2, Ankita Shrivastava1, Pooja Arora3, Udipta Sahoo4, Sameer Gupta5  \n1Department of Dentistry, Gajra Raja Medical College, Gwalior, Madhya Pradesh, India, 2Department of  \nOral and Maxillofacial Surgery, Mahsa University, Kuala Langat, Selangor, Malaysia, 3Department of Prosthodontics, Faculty of Dentistry, Taif University, kingdom of Saudi Arabia, 4Kalinga Institute of Dental Sciences, KIIT Deemed tobe University, Bhubaneswar, Odisha, India, 5Department of Oral and Maxillofacial Surgery, Inderprastha Dental College and Hospital, Ghaziabad, Uttar Pradesh, India  \nSubmitted: 04‑Jul‑2025  \nRevised: 07‑Jul‑2025  \nAccepted: 26‑Jul‑2025  \nPublished: 17‑Dec‑2025  \nAbstract  \nBackground: Titanium plates have long been the gold standard in mandibular fracture fixation. However, concerns regarding palpability, imaging artifacts, and the need for hardware removal have prompted the development of resorbable fixation systems. Despite their increasing use, comparative data on their efficacy and safety remain limited. Objective: This study aims to compare the clinical outcomes of resorbable and titanium fixation systems in the management of mandibular fractures. Materials and Methods: A prospective, randomized clinical trial was conducted on 60 patients with isolated mandibular fractures. Thirty patients were treated with titanium miniplates and screws, while the remaining 30 received resorbable poly-L-lactic acid (PLLA) fixation. Patients were evaluated at 1 week, 1 month, and 3 months postoperatively for stability, infection, wound healing, and neurosensory deficits. Results: Both groups showed similar rates of fracture union at 3 months (titanium: 96.7%, resorbable: 93.3%; P = 0.56) . The mean operative time was significantly higher in the resorbable group (92.4 ± 12.6 min) compared to the titanium group (76.8 ± 10.9 min; P \u003C 0.001) . Transient wound dehiscence occurred in two patients (6.7%) in the resorbable group and 1 (3.3%) in the titanium group. No significant differences were observed in infection rates (P = 0.65) or neurosensory complications (P = 0.78) . Conclusion: Resorbable fixation systems demonstrate comparable clinical outcomes to titanium in mandibular fracture management, albeit with a longer operative time. These systems may offer an alternative for patients desiring implant‑free recovery, particularly in pediatric or aesthetically sensitive populations.  \nKeywords: Fixation, fracture, oral surgery, titanium   \nIntroduction  \nM  \nandibular proportion  \nfractures account for a substantial of maxillofacial injuries and require  \nprompt and stable fixation to restore function and aesthetics.[1] Titanium miniplates have traditionally been considered the gold standard due to their rigidity, biocompatibility, and ease of use.[2] However, complications such as palpability, temperature sensitivity, interference with imaging, and the need for secondary surgery for hardware removal have led to the exploration of alternative fixation materials.[3]  \nResorbable fixation systems made from polymers such as polylactic acid (PLA) and polyglycolic acid (PGA)  \n\n| Access this article online |  |\n| --- | --- |\n| Quick Response Code:\u003Cbr>| Website: [https://journals.lww.com/jpbs](https://journals.lww.com/jpbs) |\n|  | DOI: 10.4103/jpbs.jpbs_1173_25 |\n\nhave emerged as promising alternatives. These materials degrade over time, eliminating the need for removal and minimizing long‑term foreign body presence.[4] Recent advancements have improved the mechanical strength and degradation profiles of these materials, allowing their application even in load‑bearing regions of the mandible.[5]  \nSeveral clinical studies have reported acceptable outcomes with resorbable systems, but concerns persist  \n\n| Address for correspondence: Dr. Ankita Shrivastava, Department of Dentistry, Gajra Raja Medical","cbCaieKIZUgWAP8B","https://ap.wps.com/l/cbCaieKIZUgWAP8B","pdf",562447,"English","# Abstract\n## Background\n## Objective\n## Materials and Methods\n## Results\n## Conclusion\n# Introduction\n# Materials and Methods","[{\"question\":\"What clinical outcomes were compared between resorbable and titanium fixation systems?\",\"answer\":\"The trial compared stability, infection, wound healing, and neurosensory deficits at 1 week, 1 month, and 3 months after surgery.\"},{\"question\":\"How was the study designed and how many patients were included?\",\"answer\":\"A prospective randomized clinical trial enrolled 60 patients with isolated mandibular fractures, assigning 30 to titanium fixation and 30 to resorbable PLLA fixation.\"},{\"question\":\"Were fracture union and infection rates different between the two fixation methods?\",\"answer\":\"Fracture union rates at 3 months were similar (titanium 96.7% vs resorbable 93.3%, P = 0.56), and infection rates showed no significant difference (P = 0.65).\"},{\"question\":\"What key difference did the study find regarding operative time?\",\"answer\":\"Mean operative time was significantly higher in the resorbable group (92.4 ± 12.6 min) compared with the titanium group (76.8 ± 10.9 min; P \\u003c 0.001).\"}]","Comparative Evaluation of Resorbable Versus Titanium Fixation Systems in Mandibular Fracture Management | PDF",[148,152,156],{"page_no":8,"url":149,"width":150,"height":151},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/dcd81bc69959e90d9f4541ab5184b44f.webp",983,1272,{"page_no":14,"url":153,"width":154,"height":155},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/79844395276c8e6aa215b014cceef576.webp",982,1270,{"page_no":81,"url":157,"width":158,"height":159},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/40260e18e1f8b3f9bba50cf21466f2f9.webp",981,1269]