[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-460222-105":3,"doc-detail-460222-en":81,"detail-sidebar-cat-0-en-105":109},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","comparative-evaluation-of-centering-ability-and-canal-transportation-using-manual-and-rotary-instruments-an-in-vitro-study","Comparative Evaluation of Centering Ability and Canal Transportation Using Manual and Rotary Instruments - An In Vitro Study","","Endodontic success depends on precise shaping and cleaning of root canals, particularly in curved anatomies where procedural errors such as canal transportation can compromise outcomes. This in vitro study evaluated manual and rotary instrumentation by comparing canal transportation and centering ability at 2, 4, and 6 mm from the apex using CBCT-based measurements. One hundred two mandibular molars with mesiobuccal canals were assigned to K-file, NeoEndo S, or GenEndo groups, followed by size 25/02 or 25/04 preparation.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/comparative-evaluation-of-centering-ability-and-canal-transportation-using-manual-and-rotary-instruments-an-in-vitro-study/460222/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/comparative-evaluation-of-centering-ability-and-canal-transportation-using-manual-and-rotary-instruments-an-in-vitro-study/460222.png","ImageObject",300,407,{"name":42,"@type":43},"pop out","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-29","2026-09-30",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",5,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What instruments were compared for canal transportation and centering ability?","Question",{"text":63,"@type":64},"The study compared manual K-files (Group I), NeoEndo S rotary files (Group II), and GenEndo rotary files (Group III).","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How were canal transportation and centering ability measured in this study?",{"text":68,"@type":64},"Cone beam computed tomography (CBCT) scans were taken before and after instrumentation, and assessments were performed at 2, 4, and 6 mm from the apex using standard formulas.",{"name":70,"@type":61,"acceptedAnswer":71},"What were the main findings regarding centering ability?",{"text":72,"@type":64},"All instruments produced some canal transportation, while centering ability differed significantly in the GenEndo group, with GenEndo files showing better centering and less deviation than NeoEndo S and K-files.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},460222,1790758042,{"code":4,"msg":82,"data":83},"success",{"doc_id":79,"user_id":84,"nickname":42,"user_avatar":85,"doc_module":4,"category_id":86,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":87,"file_id":88,"file_url":89,"file_type":90,"file_size":91,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":30,"language":92,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":93,"faqs":94,"seo_title":95,"seo_description":12,"update_tm":80,"read_time":86,"preview_page_count":30,"preview_urls":96},962090760408,"https://ap-avatar.wpscdn.com/davatar_085a072bc5b1113ac321206ff7593b45",8,"Original Research  \nComparative Evaluation of Centering Ability and Canal Transportation Using Manual and Rotary Instruments – An In Vitro Study  \nTahera Shamim, Priyanka, Mehar Fatima, Amit Kumar  \nDepartment of Conservative Dentistry and Endodontics, Mithila Minority Dental College and Hospital, Darbhanga, Bihar, India  \nSubmitted: 28‑May‑2025  \nRevised: 03‑Jun‑2025  \nAccepted: 23‑Jun‑2025  \nPublished: 17‑Dec‑2025  \nAbstract  \nBackground: Endodontic success relies heavily on the accurate shaping and cleaning of root canals, especially in curved canals where procedural errors like canal transportation can occur. Instrument design, alloy flexibility, and taper significantly influence canal shaping outcomes. Materials and Methods: A total of 102 extracted mandibular molars with uncalcified, noncarious mesiobuccal canals were selected. Teeth were divided into three groups: Group I (K-file), Group II (NeoEndo S rotary), and Group III (GenEndo rotary) . After access cavity preparation and initial glide path formation, root canals were prepared to size 25/02 (manual) and 25/04 (rotary). Cone beam computed tomography scans were performed pre‑ and postinstrumentation at 2, 4, and 6 mm from the apex to assess canal transportation and centering ability using standard formulas. Results: Group I (K-files) showed minimal mesiobuccal (MB) transportation at 2 mm (0.01 ± 0.22 mm) and the highest centering ratio at 2 mm (0.62 ± 0.85) . Group II (NeoEndo S) had the highest transportation at 2 mm (MB: [0.10 ± 0.35 mm], DL: [0.51 ± 1.30 mm]) and the lowest centering ability (0.13 ± 1.75) . At 4 mm, NeoEndo S again showed maximum transportation ([0.06 ± 0.35] MB, [0.53 ± 0.93] DL) compared to GenEndo and K-files. At 6 mm, Group III (GenEndo) showed greater MB transportation (0.31 ± 0.54 mm) and the lowest centering ability (0.01 ± 0.83) . ANOVA revealed no significant differences for MB and DL transportation (P > 0.05 across groups), but centering ability differed significantly in Group III (P = 0.023), particularly between 2 and 4 mm distances. Conclusion: All tested instruments caused some degree of canal transportation. GenEndo files demonstrated better centering ability and less canal deviation compared to NeoEndo S and K-files, attributed to their design and alloy properties.  \nKeywords: Canal transportation, CBCT, centering ability, GenEndo, K‑files, NeoEndo S, nickel‑titanium files, root canal preparation, rotary instrumentation   \nIntroduction  \nEndodontics is the dental specialty  \nwith the prevention, diagnosis, and  \nconcerned treatment  \nof diseases of the dental pulp and periapical tissues. A critical component of successful root canal therapy is the effective chemomechanical preparation of the canal system, which includes shaping, cleaning, disinfection, and, ultimately, obturation with a hermetic seal in three dimensions. [1] The primary aim of canal shaping is to create a continuous tapering funnel from the coronal portion to the apical  \n\n| Access this article online |  |\n| --- | --- |\n| Quick Response Code:\u003Cbr>| Website: [https://journals.lww.com/jpbs](https://journals.lww.com/jpbs) |\n|  | DOI: 10.4103/jpbs.jpbs_988_25 |\n\nterminus, maintaining the original canal curvature and anatomy. [2]  \nAccording to Schilder’s principles, mechanical objectives of shaping include producing a continuously tapering canal that maintains the original anatomy and facilitates obturation, while biological objectives involve  \n\n| Address for correspondence: Dr. Tahera Shamim, Department of Conservative Dentistry and Endodontics, Mithila Minority Dental College and Hospital, Darbhanga, Bihar, India.\u003Cbr>E‑mail: [taheraofficial3@gmail.com](taheraofficial3@gmail.com) |\n| --- |\n| This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License (CC BY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or use","cbCaitoYiqrlh0jh","https://ap.wps.com/l/cbCaitoYiqrlh0jh","pdf",611268,"English","# Abstract\n# Introduction\n# Materials and Methods","[{\"question\":\"What instruments were compared for canal transportation and centering ability?\",\"answer\":\"The study compared manual K-files (Group I), NeoEndo S rotary files (Group II), and GenEndo rotary files (Group III).\"},{\"question\":\"How were canal transportation and centering ability measured in this study?\",\"answer\":\"Cone beam computed tomography (CBCT) scans were taken before and after instrumentation, and assessments were performed at 2, 4, and 6 mm from the apex using standard formulas.\"},{\"question\":\"What were the main findings regarding centering ability?\",\"answer\":\"All instruments produced some canal transportation, while centering ability differed significantly in the GenEndo group, with GenEndo files showing better centering and less deviation than NeoEndo S and K-files.\"}]","Comparative Evaluation of Centering Ability and Canal Transportation Using Manual and Rotary Instruments - An In Vitro Study | PDF",[97,101,105],{"page_no":22,"url":98,"width":99,"height":100},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/00f201c39689a55fe55647b008f10299.webp",983,1272,{"page_no":26,"url":102,"width":103,"height":104},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/1b07f5a9321a2a625289f31820d39cb1.webp",982,1270,{"page_no":30,"url":106,"width":107,"height":108},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/56976153c67d49d2e03fcafb4e4a8896.webp",981,1269,{"code":4,"msg":82,"data":110},[111,115,119,123,127,132,137,140,145,148,152],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":112,"show_sort_weight":113,"slug":114},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":121,"slug":122},"Exam",70,"exam",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":125,"slug":126},"Comic",60,"comic",{"id":128,"doc_module":4,"doc_module_name":25,"category_name":129,"show_sort_weight":130,"slug":131},6,"Technology",50,"technology",{"id":133,"doc_module":4,"doc_module_name":25,"category_name":134,"show_sort_weight":135,"slug":136},7,"Healthcare",40,"healthcare",{"id":86,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":138,"slug":139},30,"research-report",{"id":141,"doc_module":4,"doc_module_name":25,"category_name":142,"show_sort_weight":143,"slug":144},9,"Religion & Spirituality",20,"religion-spirituality",{"id":143,"doc_module":4,"doc_module_name":25,"category_name":146,"show_sort_weight":143,"slug":147},"World Cup","world-cup",{"id":149,"doc_module":4,"doc_module_name":25,"category_name":150,"show_sort_weight":149,"slug":151},10,"Lifestyle","lifestyle",{"id":153,"doc_module":4,"doc_module_name":25,"category_name":154,"show_sort_weight":55,"slug":155},19,"General","general"]