[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-386201-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-386201-en":131},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","comparative-assessment-of-different-ultrasound-technologies-in-the-detection-of-prostate-cancer-a-systematic-review-and-meta-analysis","Comparative Assessment of Different Ultrasound Technologies in the Detection of Prostate Cancer - A Systematic Review and Meta-Analysis","","The present study assesses the diagnostic test accuracy of different ultrasound scanning technologies for detecting prostate cancer. A systematic search used the Cochrane Guidelines for Screening and Diagnostic Tests across PubMed, Medline, Ovid, Embase, and the Cochrane Library. Eligibility screening identified 26 studies with 6370 patients. QUADAS-2 supported quality and bias evaluation. Pooled sensitivity ranged from 0.66 for grayscale to 0.87 for mpUS, while pooled specificity ranged from 0.56 for grayscale to 0.78 for CEUS.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/comparative-assessment-of-different-ultrasound-technologies-in-the-detection-of-prostate-cancer-a-systematic-review-and-meta-analysis/386201/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/comparative-assessment-of-different-ultrasound-technologies-in-the-detection-of-prostate-cancer-a-systematic-review-and-meta-analysis/386201.png","ImageObject",300,407,{"name":42,"@type":43},"Melati","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-24","2026-09-24",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",12,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What diagnostic ultrasound technologies were compared in the study?","Question",{"text":63,"@type":64},"The review evaluated Micro-US, mpUS, SWE, CEUS, and grayscale ultrasound as primary detection modalities for prostate cancer.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How were studies selected and quality assessed?",{"text":68,"@type":64},"The authors conducted a systematic search using Cochrane Guidelines for Screening and Diagnostic Tests and assessed study quality and bias using the QUADAS-2 tool.",{"name":70,"@type":61,"acceptedAnswer":71},"What were the main pooled sensitivity and specificity findings?",{"text":72,"@type":64},"Pooled sensitivity ranged from 0.66 (grayscale) to 0.87 (mpUS), while pooled specificity ranged from 0.56 (grayscale) to 0.78 (CEUS), with substantial heterogeneity reported across studies.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},386201,1790318939,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,115,120,123,127],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":112,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":113,"slug":114},8,30,"research-report",{"id":116,"doc_module":4,"doc_module_name":25,"category_name":117,"show_sort_weight":118,"slug":119},9,"Religion & Spirituality",20,"religion-spirituality",{"id":118,"doc_module":4,"doc_module_name":25,"category_name":121,"show_sort_weight":118,"slug":122},"World Cup","world-cup",{"id":124,"doc_module":4,"doc_module_name":25,"category_name":125,"show_sort_weight":124,"slug":126},10,"Lifestyle","lifestyle",{"id":128,"doc_module":4,"doc_module_name":25,"category_name":129,"show_sort_weight":97,"slug":130},19,"General","general",{"code":4,"msg":82,"data":132},{"doc_id":79,"user_id":133,"nickname":42,"user_avatar":134,"doc_module":4,"category_id":112,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":118,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":104,"preview_page_count":33,"preview_urls":145},962085570644,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","cancers   \nSystematic Review  \nComparative Assessment of Different Ultrasound Technologies in the Detection of Prostate Cancer: A Systematic Review and Meta-Analysis  \nDareen Alghamdi 1,2, *, Neil Kernohan 3, Chunhui Li 4 and Ghulam Nabi 1, *  \nCitation: Alghamdi, D.; Kernohan, N.; Li, C.; Nabi, G. Comparative Assessment of Different Ultrasound Technologies in the Detection of Prostate Cancer: A Systematic Review and Meta-Analysis. Cancers 2023, 15, 4105. [https://doi.org/](https://doi.org/)[ ](https://doi.org/)[10.3390/cancers15164105](10.3390/cancers15164105)  \nAcademic Editor: Giorgio Treglia  \nReceived: 20 June 2023  \nRevised: 10 August 2023  \nAccepted: 11 August 2023  \nPublished: 15 August 2023  \nCopyright: © 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license ([https://](https://)[ ](https://)[creativecommons.org/licenses/by/](creativecommons.org/licenses/by/)[ ](creativecommons.org/licenses/by/)[4.0/](4.0/)) .  \n1 Division of Imaging Sciences and Technology, School of Medicine, Ninewells Hospital, University of Dundee, Dundee DD1 9SY, UK  \n2 Radiology Department, College of Applied Medical Sciences, Imam Abdulrahman Bin Faisal University, P.O. Box 1982, Dammam 31441, Saudi Arabia  \n3 Department of Pathology, Ninewells Hospital, Dundee DD9 1SY, UK; [n.m.kernohan@dundee.ac.uk](n.m.kernohan@dundee.ac.uk)  \n4 School of Science and Engineering, University of Dundee, Dundee DD1 4HN, UK; [c.li@dundee.ac.uk](c.li@dundee.ac.uk)  \n* Correspondence: [dalghamdi@dundee.ac.uk](dalghamdi@dundee.ac.uk) (D.A.); [g.nabi@dundee.ac.uk](g.nabi@dundee.ac.uk) (G.N.)  \nSimple Summary: Prostate cancer (PCa) is considered as one of main causes of death in men globally. More research is required on the diagnostic accuracy of mpUS and advanced modalities in prostate cancer detection, which may provide insightful information into the diagnostic accuracy and clinical utility of this technique. Therefore, we have conducted a systematic review and meta-analysis to assess the diagnostic test accuracy of different ultrasound scanning technologies (shear-wave elastography, contrast enhanced, micro-ultrasound) and grayscale ultrasound technology in the detection of prostate cancer. This will assist in determining whether this new method of detecting prostate cancer is effective. Our results showed that some studies proved that advanced ultrasound modalities are promising methods for the detection of prostate cancer.  \nAbstract: The present study aimed to assess the diagnostic test accuracy of different ultrasound scanning technologies in the detection of prostate cancer. A systematic search was conducted using the Cochrane Guidelines for Screening and Diagnostic Tests. We performed a systematic search in the international databases PubMed, Medline, Ovid, Embase and Cochrane Library. Searches were designed to ﬁnd all studies that evaluated Micro-US, mpUS, SWE and CEUS as the main detection modalities for prostate cancer. This study was registered with Research Registry of systematic review and meta-analysis. The QUADAS-2 tool was utilized to perform quality assessment and bias analysis. The literature search generated 1376 studies. Of these, 320 studies were screened for eligibility, with 1056 studies being excluded. Overall, 26 studies with a total of 6370 patients met the inclusion criteria. The pooled sensitivity for grayscale, CEUS, SWE, Micro-US and mpUS modalities were 0.66 (95% CI 0.54–0.73) 0.73 (95% CI 0.58–0.88), 0.82 (95% CI 0.75–0.90), 0.85 (95% CI 0.76–0.94) and 0.87 (95% CI 0.71–1.03), respectively. Moreover, the pooled speciﬁcity for grayscale, CEUS, SWE, Micro-US and mpUS modalities were 0.56 (95% CI 0.21–0.90), 0.78 (95% CI 0.67–0.88), 0.76 (95% CI 0.65–0.88), 0.43 (95% CI 0.28–0.59) and 0.68 (95% CI 0.54–0.81), respectively. In terms of sensitivity, substantial heterogeneity between studies was detected","cbCaiiAgGPKwO05K","https://ap.wps.com/l/cbCaiiAgGPKwO05K","pdf",3115643,"English","# Abstract\n# Introduction","[{\"question\":\"What diagnostic ultrasound technologies were compared in the study?\",\"answer\":\"The review evaluated Micro-US, mpUS, SWE, CEUS, and grayscale ultrasound as primary detection modalities for prostate cancer.\"},{\"question\":\"How were studies selected and quality assessed?\",\"answer\":\"The authors conducted a systematic search using Cochrane Guidelines for Screening and Diagnostic Tests and assessed study quality and bias using the QUADAS-2 tool.\"},{\"question\":\"What were the main pooled sensitivity and specificity findings?\",\"answer\":\"Pooled sensitivity ranged from 0.66 (grayscale) to 0.87 (mpUS), while pooled specificity ranged from 0.56 (grayscale) to 0.78 (CEUS), with substantial heterogeneity reported across studies.\"}]","Comparative Assessment of Different Ultrasound Technologies in the Detection of Prostate Cancer - A Systematic Review and Meta-Analysis | PDF",1790272746,[146,150,154,158],{"page_no":22,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/292b16874f8abe1f0412a08dc85eb6e6.webp",983,1390,{"page_no":26,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/c0704c9632d6ee66a38a4965e5246243.webp",982,1388,{"page_no":30,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/fd1888f13eb121b0abe1e7aa3227b884.webp",981,1387,{"page_no":33,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/934737e0df348c943b084881772fe732.webp",980,1385]