[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-461434-105":59,"doc-detail-461434-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","comparative-analysis-of-implant-placement-accuracy-using-augmented-reality-technology-versus-3d-printed-surgical-guides-a-controlled-in-vitro-study","Comparative Analysis of Implant Placement Accuracy Using Augmented Reality Technology Versus 3D-Printed Surgical Guides - A Controlled In Vitro Study","","Objective: Evaluate and compare the precision of dental implant placements using augmented reality (AR) iPhone navigation versus conventional 3D-printed surgical guides. Methods: Fourteen standardized mandibular models were assigned to AR-guided and 3D-printed guide groups; each received four implants in predefined positions. Postoperative CBCT scans were aligned to surgical plans in Exocad to measure 3D deviations (entry, apex, and angular error) and analyze results with Statistica. Results: The AR group showed smaller entry and apex deviations and significantly lower angular deviation (p\u003C0.05).",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/comparative-analysis-of-implant-placement-accuracy-using-augmented-reality-technology-versus-3d-printed-surgical-guides-a-controlled-in-vitro-study/461434/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/comparative-analysis-of-implant-placement-accuracy-using-augmented-reality-technology-versus-3d-printed-surgical-guides-a-controlled-in-vitro-study/461434.png","ImageObject",300,407,{"name":92,"@type":93},"Guten tag","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-07","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":39},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What was the study purpose regarding implant placement accuracy?","Question",{"text":112,"@type":113},"To evaluate and compare the precision of dental implant placements using AR iPhone navigation technology versus conventional 3D-printed surgical guides under controlled in vitro conditions.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How were implant placements evaluated in this experiment?",{"text":117,"@type":113},"Fourteen standardized mandibular models were scanned with postoperative CBCT and aligned to preoperative 3D plans in Exocad to measure three-dimensional deviations, including total entry error, total apex error, and angular error.",{"name":119,"@type":110,"acceptedAnswer":120},"Which method showed better accuracy, and which metric improved the most?",{"text":121,"@type":113},"The AR group demonstrated superior accuracy with smaller mean entry and apex deviations and significantly lower angular deviation compared with the 3D-printed guide group (p\u003C0.05).","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},461434,1791081714,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":39,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":19,"preview_urls":146},687212321768,"https://ap-avatar.wpscdn.com/avatar/a0010bdbe886d2fe77?x-image-process=image/resize,m_fixed,w_180,h_180&k=1789897067658708522","Article  \nComparative Analysis of Implant Placement Accuracy Using Augmented Reality Technology Versus 3D-Printed Surgical Guides: A Controlled In Vitro Study  \nAdam Aleksander Nowicki 1, * and Marek Markiewicz 2  \nAcademic Editor: Francisco Mesa  \nReceived: 15 October 2025  \nRevised: 15 December 2025  \nAccepted: 22 December 2025  \nPublished: 27 December 2025  \nCopyright: © 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.  \n1 Diamante Clinica Dental Clinic, Sportowa 48 A/C, 59-300 Lubin, Poland  \n2 Markiewicz Clinic, Szymanowskiego 2, 80-280 Gda ´nsk, Poland  \n* Correspondence: [adamusnowicki@gmail.com](adamusnowicki@gmail.com)  \nAbstract  \nPurpose: The objective of this study was to evaluate and compare the precision of dental implant placements using augmented reality (AR)-iPhone (Apple, Cupertino, CA, USA) navigation technology versus conventional 3D-printed surgical guides. The accuracy was assessed by comparing the actual implant positions to their predefined three-dimensional (3D) locations in surgical plans using the Exocad software (Exocad, Dormstadt, Germany) . Materials and Methods: Fourteen standardized mandibular models were divided into two groups: AR-guided (AR1-AR7) and 3D-printed surgical guide-assisted (Group 1–7) . Each model received four implants in positions 35, 32, 42, and 45 . Postoperative CBCT scans were aligned with the preoperative plans in the Exocad software to measure threedimensional deviations, including total entry error, total apex error, and angular error. Statistical analysis was performed using the Statistica 12 software (StatSoft, Tulsa, OK, USA), incorporating Shapiro–Wilk normality tests, ANOVA, and post hoc LSD tests (where applicable) . Results: The in vitro comparative experiment demonstrated AR group superior accuracy with mean deviations of 0.42 ± 0.12 mm at the entry point and 0.51 ± 0.18 mm at the apex, compared to 0.48 ± 0.15 mm and 0.58 ± 0.22 mm, respectively, in the 3Dprinted guide group (p \u003C 0.05) . Angular deviation was significantly lower in the AR group (1.8◦ ± 0.6◦ ) versus the guide group (2.1◦ ± 0.7◦ , p = 0.009) . Descriptive statistics revealed the median apex error was 0.49 mm (IQR: 0.38–0.61) for AR versus 0.56 mm (IQR: 0.45–0.72) for guides. Conclusions: AR iPhone navigation technology achieved clinically acceptable accuracy compared to static 3D-printed guides, particularly in controlling angular deviations. While both methods produced clinically acceptable results, AR technology represents a significant advancement for precision-sensitive cases.  \nKeywords: augmented reality; dynamic navigation; implant surgery; full arch surgery; computer-assisted surgery; implantology; surgical guides  \n1. Introduction  \nImplant placement traditionally was, and will be, performed mostly freehand or with the application of 3D-printed surgical guides. However, both of these established protocols have limitations and some operative risk [1] . Two decades of progress and evolution of implant navigation systems have not only solved the issues related to the freehand and analog guides, but the learning curve, handling, size, and interface have been improved as well [2] .  \nModern navigation systems enable matching a patient’s surgical field with digitized prosthetically driven surgery in real time [3] . This approach can not only reduce the risk of intrasurgical injury of the anatomical structures [4], but also offers a possibility to make major changes motivated by a given situation (e.g., change in osteotomy angulation due to bone defect unseen on CBCT) [5] .  \nWith the incline and surfacing of protocols such PATZi being more popular, the dynamic navigation is shifting from fancy and fashionable to being more pragmatic. Remote anchorage helps not only to supply demanding cases but to restore well-being for a large group of elderly, geneticall","cbCaildwlVPkbAhb","https://ap.wps.com/l/cbCaildwlVPkbAhb","pdf",9099636,14,"English","# Abstract\n# Introduction\n## Background on Implant Placement Approaches\n## Role of Precision and Navigation Systems\n## Limitations of Static Guides and Potential of AR\n## Study Aim","[{\"question\":\"What was the study purpose regarding implant placement accuracy?\",\"answer\":\"To evaluate and compare the precision of dental implant placements using AR iPhone navigation technology versus conventional 3D-printed surgical guides under controlled in vitro conditions.\"},{\"question\":\"How were implant placements evaluated in this experiment?\",\"answer\":\"Fourteen standardized mandibular models were scanned with postoperative CBCT and aligned to preoperative 3D plans in Exocad to measure three-dimensional deviations, including total entry error, total apex error, and angular error.\"},{\"question\":\"Which method showed better accuracy, and which metric improved the most?\",\"answer\":\"The AR group demonstrated superior accuracy with smaller mean entry and apex deviations and significantly lower angular deviation compared with the 3D-printed guide group (p\\u003c0.05).\"}]","Comparative Analysis of Implant Placement Accuracy Using Augmented Reality Technology Versus 3D-Printed Surgical Guides - A Controlled In Vitro Study | PDF",1790761607,35,[147,151,155,159],{"page_no":8,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/ed03a69351712bf83ab0043bbb36b7f9.webp",983,1390,{"page_no":14,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/c26fed8fd18eea9f871e5031c6d0489b.webp",982,1388,{"page_no":81,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/4668df5ca88e50bf9360848ccf820865.webp",981,1387,{"page_no":19,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/77e07e88c3027ecc1e097f761aacbd3c.webp",980,1385]