[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-334292-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-334292-en":131},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","colon-tumor-discrimination-combining-independent-endoscopic-probe-based-raman-spectroscopy-and-optical-coherence-tomography-modalities-with-bayes-rule","Colon Tumor Discrimination - Combining Independent Endoscopic Probe-Based Raman Spectroscopy and Optical Coherence Tomography Modalities with Bayes Rule","","Colorectal cancer is among the most prevalent cancers worldwide, and routine diagnosis relies heavily on colonoscopy or sigmoidoscopy with frequent biopsy sampling. Optical methods, including Raman spectroscopy (RS) and optical coherence tomography (OCT), offer a path to improve diagnostic performance and reduce unnecessary biopsies. Fiber-optic probes for single-point Raman and volumetric OCT were developed for in vivo use and tested in an ex vivo clinical setting. The study evaluates whether combining the modalities improves cancer versus healthy tissue discrimination using AUC ROC scores. Both RS and OCT were validated separately with linear discriminant analysis, using spectral preprocessing for RS and texture feature extraction for OCT. Integrated with Bayes rule, the combined approach achieved an AUC ROC of 0.93, exceeding 0.77 for RS and 0.86 for OCT.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/colon-tumor-discrimination-combining-independent-endoscopic-probe-based-raman-spectroscopy-and-optical-coherence-tomography-modalities-with-bayes-rule/334292/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/colon-tumor-discrimination-combining-independent-endoscopic-probe-based-raman-spectroscopy-and-optical-coherence-tomography-modalities-with-bayes-rule/334292.png","ImageObject",300,407,{"name":42,"@type":43},"Genevieve","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-26","2026-09-21",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",11,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What diagnostic limitation motivates combining Raman spectroscopy and OCT?","Question",{"text":63,"@type":64},"Routine colorectal cancer diagnosis often relies on colonoscopy or sigmoidoscopy with biopsy removal. Raman spectroscopy and OCT are explored to improve diagnostics and reduce unnecessary biopsies.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How were Raman spectroscopy and OCT validated before being combined?",{"text":68,"@type":64},"Raman spectroscopy used spectral preprocessing and was validated separately with linear discriminant analysis. OCT underwent texture feature extraction and was also validated separately with linear discriminant analysis.",{"name":70,"@type":61,"acceptedAnswer":71},"How does the combined Bayes-rule approach perform compared with using each modality alone?",{"text":72,"@type":64},"Bayes-rule integration produced an AUC ROC score of 0.93, improving over Raman spectroscopy alone (0.77) and OCT alone (0.86).","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},334292,1790083873,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,115,120,123,127],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":112,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":113,"slug":114},8,30,"research-report",{"id":116,"doc_module":4,"doc_module_name":25,"category_name":117,"show_sort_weight":118,"slug":119},9,"Religion & Spirituality",20,"religion-spirituality",{"id":118,"doc_module":4,"doc_module_name":25,"category_name":121,"show_sort_weight":118,"slug":122},"World Cup","world-cup",{"id":124,"doc_module":4,"doc_module_name":25,"category_name":125,"show_sort_weight":124,"slug":126},10,"Lifestyle","lifestyle",{"id":128,"doc_module":4,"doc_module_name":25,"category_name":129,"show_sort_weight":97,"slug":130},19,"General","general",{"code":4,"msg":82,"data":132},{"doc_id":79,"user_id":133,"nickname":42,"user_avatar":134,"doc_module":4,"category_id":112,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":140,"language":141,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":12,"update_tm":145,"read_time":146,"preview_page_count":26,"preview_urls":147},1374391974585,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","Article  \nColon Tumor Discrimination Combining Independent Endoscopic Probe-Based Raman Spectroscopy and Optical Coherence Tomography Modalities with Bayes Rule  \nDavid L. Vasquez 1, Calvin Kreft 2, Ines Latka 1, Jürgen Popp 1,3, René Mantke 4,5 and Iwan W. Schie 1,2, *  \nCitation: Vasquez, D.L.; Kreft, C.; Latka, I.; Popp, J.; Mantke, R.; Schie, I.W. Colon Tumor Discrimination Combining Independent Endoscopic Probe-Based Raman Spectroscopy and Optical Coherence Tomography Modalities with Bayes Rule. Int. J. Mol. Sci. 2024, 25, 13306. [https://](https://)[ ](https://)[doi.org/10.3390/ijms252413306](doi.org/10.3390/ijms252413306)  \nAcademic Editor: Hidekazu Suzuki  \nReceived: 31 October 2024  \nRevised: 2 December 2024  \nAccepted: 6 December 2024  \nPublished: 11 December 2024  \nCopyright: © 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license ([https://](https://)[ ](https://)[creativecommons.org/licenses/by/](creativecommons.org/licenses/by/)[ ](creativecommons.org/licenses/by/)[4.0/](4.0/)) .  \n1 Leibniz-Institute of Photonic Technology (Leibniz-IPHT), Albert-Einstein-Str. 9, 07745 Jena, Germany; [davidl.vasquez-pinzon@leibniz-ipht.de](davidl.vasquez-pinzon@leibniz-ipht.de) (D.L.V.); [ines.latka@leibniz-ipht.de](ines.latka@leibniz-ipht.de) (I.L.); [juergen.popp@leibniz-ipht.de](juergen.popp@leibniz-ipht.de) (J.P.)  \n2 Department of Medical Engineering and Biotechnology, University of Applied Sciences—Jena, Carl-Zeiss-Promenade 2, 07745 Jena, Germany; [calvin.kreft@eah-jena.de](calvin.kreft@eah-jena.de)  \n3 Institute of Physical Chemistry (IPC), Abbe Center of Photonics (ACP), Friedrich-Schiller-University Jena, Helmholtzweg 4, 07743 Jena, Germany  \n4 Clinic for General and Visceral Surgery, University Hospital Brandenburg an der Havel, Brandenburg Medical School, 14770 Brandenburg an der Havel, Germany; mantke.mhb@uk-brandenburg.de  \n5 Faculty of Health Sciences Brandenburg, Brandenburg Medical School, 14770 Brandenburg an der Havel, Germany  \n* Correspondence: [iwan.schie@leibniz-ipht.de](iwan.schie@leibniz-ipht.de); Tel.: +49-3641-206-313  \nAbstract: Colorectal cancer is one of the most prevalent forms of cancer globally. The most common routine diagnostic methods are the examination of the interior of the colon during colonoscopy or sigmoidoscopy, which frequently includes the removal of a biopsy sample. Optical methods, such as Raman spectroscopy (RS) and optical coherence tomography (OCT), can help to improve diagnosticsand reduce the number of unnecessary biopsies. For in vivo use, we have developed fiber-optic probes, one for single-point Raman measurements and one for volumetric OCT. Here, we present the results of a clinical study using these fiber-optic probes in an ex vivo setting. The goal was to evaluate the beneficial effect of combining these two modalities on the AUC ROC score of the machine learning models for the discrimination of cancerous and healthy tissue. In the initial stage of the investigation, both modalities were validated separately using linear discriminant analysis. RS was subjected to spectral preprocessing, while OCT underwent texture feature extraction. Subsequently, both modalities were integrated using the Bayes rule, resulting in an enhanced area under the curve score of 0.93, representing an improvement over the 0.77 score for Raman spectroscopy and 0.86 for OCT.  \nKeywords: colon cancer; Raman spectroscopy; optical coherence tomography; OCT; fiber-optic probes; clinical application; biophotonics; invaScope  \n1. Introduction  \nIn 2022, colorectal cancer was the prevalent form of cancer globally, with 1,926,425 new cases reported; 904,019 deaths; and a 5-year prevalence of 5,767,781 cases [1] . The World Health Organization [2] expects that by 2040, the number of cases will increase by 63%, i.e., 3.2 million new cases per year, with a 73% increase in the n","cbCaic4pQ84q38Hh","https://ap.wps.com/l/cbCaic4pQ84q38Hh","pdf",4220495,17,"English","# Introduction\n## Clinical need and epidemiology\n## Optical modalities and rationale\n## Study design and integration strategy","[{\"question\":\"What diagnostic limitation motivates combining Raman spectroscopy and OCT?\",\"answer\":\"Routine colorectal cancer diagnosis often relies on colonoscopy or sigmoidoscopy with biopsy removal. Raman spectroscopy and OCT are explored to improve diagnostics and reduce unnecessary biopsies.\"},{\"question\":\"How were Raman spectroscopy and OCT validated before being combined?\",\"answer\":\"Raman spectroscopy used spectral preprocessing and was validated separately with linear discriminant analysis. OCT underwent texture feature extraction and was also validated separately with linear discriminant analysis.\"},{\"question\":\"How does the combined Bayes-rule approach perform compared with using each modality alone?\",\"answer\":\"Bayes-rule integration produced an AUC ROC score of 0.93, improving over Raman spectroscopy alone (0.77) and OCT alone (0.86).\"}]","Colon Tumor Discrimination - Combining Independent Endoscopic Probe-Based Raman Spectroscopy and Optical Coherence Tomography Modalities with Bayes Rule | PDF",1790006153,43,[148,152],{"page_no":22,"url":149,"width":150,"height":151},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-08/65bc06f5143427843e5b3c81cd3458c3.webp",983,1390,{"page_no":26,"url":153,"width":154,"height":155},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-08/4f1380434bed0777fda59edb962a51b0.webp",982,1388]