[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-650519-105":59,"doc-detail-650519-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","cold-formed-metal-framing-section-05-40-00-650519","Cold-Formed Metal Framing - Section 05 40 00","","Specification section outlining requirements for exterior non-load-bearing wall framing, roof rafter framing, and soffit framing using cold-formed steel. Covers related sections, required preinstallation conference option, action and informational submittals (product data, shop drawings, qualification data, welding certificates, test reports, and ICC-ES research reports), and quality assurance through ASTM/ AWS qualification and specified steel and fastening test documentation. Establishes delivery and protection measures, manufacturer options, delegated design by a qualified engineer, and structural performance criteria including deflection limits and temperature-change movement allowances.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/cold-formed-metal-framing-section-05-40-00-650519/650519/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/cold-formed-metal-framing-section-05-40-00-650519/650519.png","ImageObject",300,407,{"name":92,"@type":93},"Blitz","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-24",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What types of cold-formed metal framing does this section cover?","Question",{"text":112,"@type":113},"It specifies exterior non-load-bearing wall framing, roof rafter framing, and soffit framing.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What are the required action submittals for cold-formed steel framing?",{"text":117,"@type":113},"Product data for each framing product and accessory, shop drawings showing layout and fastening details, and delegated-design submittals for cold-formed steel framing.",{"name":119,"@type":110,"acceptedAnswer":120},"How does the specification address performance and deflection limits?",{"text":121,"@type":113},"It requires delegated design by a qualified engineer and establishes deflection limits for exterior non-load-bearing framing, roof rafter framing, and soffit framing, including movement allowances under maximum ambient temperature change.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},650519,1793106829,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":52,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144},24464137899374,"https://us-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","SECTION 05 40 00-COLD-FORMED METAL FRAMING  \nPART 1-GENERAL  \n1.1 RELATED DOCUMENTS  \nA. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.  \nB. The Contractor's attention is specifically directed, but not limited, to the following documents for additional requirements:  \n1. Uniform General Conditions for Construction Contracts, State of Texas, 2010 (UGC) .  \n2. The University of Houston’s Supplemental General Conditions and Special Conditions for Construction.  \n1.2 SUMMARY  \nA. Section Includes:  \n1. Exterior non-load-bearing wall framing.  \n2. Roof rafter framing.  \n3. Soffit framing.  \nB. Related Requirements:  \n1. Section 05 50 00 \"Metal Fabrications\" for masonry shelf angles and connections.  \n2. Section 09 21 16.23 \"Gypsum Board Shaft Wall Assemblies\" for interior non-loadbearing, metal-stud-framed, shaft-wall assemblies.  \n3. Section 09 22 16 \"Non-Structural Metal Framing\" for interior non-load-bearing, metalstud framing and ceiling-suspension assemblies.  \n1.3 PREINSTALLATION MEETINGS  \nRetain \"Preinstallation Conference\" Paragraph below if Work of this Section is extensive or complex enough to justify a conference.  \nA. Preinstallation Conference: Conduct conference at Project site .  \n1.4 ACTION SUBMITTALS  \nA. Product Data: For each type of cold-formed steel framing product and accessory.  \nB. LEED Submittals (Projects authorized for LEED certification only):  \n1. Product Data for Credit MR 4: For products having recycled content, documentation indicating percentages by weight of postconsumer and preconsumer recycled content. Include statement indicating cost for each product having recycled content.  \nC. Shop Drawings:  \n1. Include layout, spacings, sizes, thicknesses, and types of cold-formed steel framing; fabrication; and fastening and anchorage details, including mechanical fasteners.  \n2. Indicate reinforcing channels, opening framing, supplemental framing, strapping, bracing, bridging, splices, accessories, connection details, and attachment to adjoining work.  \nD. Delegated-Design Submittal: For cold-formed steel framing.  \n1.5 INFORMATIONAL SUBMITTALS  \nA. Qualification Data: For testing agency.  \nB. Welding certificates.  \nC. Product Test Reports: For each listed product, for tests performed by a qualified testing agency.  \n1. Steel sheet.  \n2. Expansion anchors.  \n3. Power-actuated anchors.  \n4. Mechanical fasteners.  \n5. Vertical deflection clips.  \n6. Horizontal drift deflection clips  \n7. Miscellaneous structural clips and accessories.  \nD. Research Reports: For non-standard cold-formed steel framing, from ICC-ES.  \n1.6 QUALITY ASSURANCE  \nA. Testing Agency Qualifications: Qualified according to ASTM E 329 for testing indicated.  \nB. Product Tests: Mill certificates or data from a qualified independent testing agency indicating steel sheet complies with requirements, including base-metal thickness, yield strength, tensile strength, total elongation, chemical requirements, and metallic-coating thickness.  \nC. Welding Qualifications: Qualify procedures and personnel according to the following:  \n1. AWS D1 . 1/D1 . 1M, \"Structural Welding Code-Steel. \"  \n2. AWS D1 .3/D1 .3M, \"Structural Welding Code-Sheet Steel. \"  \n1.7 DELIVERY, STORAGE, AND HANDLING  \nA. Protect cold-formed steel framing from corrosion, moisture staining, deformation, and other damage during delivery, storage, and handling.  \nPART 2-PRODUCTS  \n2.1 MANUFACTURERS  \nA.  Manufacturers: Subject to compliance with requirements, provide products by one of the following :  \n1.  ClarkDietrich Metal Framing; a Worthington Industries Company, [www.clarkdietrich.com](www.clarkdietrich.com)  \n2.  MarinoWARE, [www. marinoware.com](www. marinoware.com).  \n3.  SCAFCO Corporation, [www.scafco.com](www.scafco.com).  \n4. Substitutions: See Section 01 25 00-Substitution Procedures.  \n2.2 PERFORMANCE REQUIREMENTS  \nA. Delegated Design: Engage a quali","cbCaiq10cJ2wx3di","https://ap.wps.com/l/cbCaiq10cJ2wx3di","pdf",155720,"English","# PART 1-GENERAL\n## 1.1 RELATED DOCUMENTS\n## 1.2 SUMMARY\n## 1.4 ACTION SUBMITTALS\n## 1.5 INFORMATIONAL SUBMITTALS\n## 1.6 QUALITY ASSURANCE\n## 1.7 DELIVERY, STORAGE, AND HANDLING\n# PART 2-PRODUCTS\n## 2.1 MANUFACTURERS\n## 2.2 PERFORMANCE REQUIREMENTS","[{\"question\":\"What types of cold-formed metal framing does this section cover?\",\"answer\":\"It specifies exterior non-load-bearing wall framing, roof rafter framing, and soffit framing.\"},{\"question\":\"What are the required action submittals for cold-formed steel framing?\",\"answer\":\"Product data for each framing product and accessory, shop drawings showing layout and fastening details, and delegated-design submittals for cold-formed steel framing.\"},{\"question\":\"How does the specification address performance and deflection limits?\",\"answer\":\"It requires delegated design by a qualified engineer and establishes deflection limits for exterior non-load-bearing framing, roof rafter framing, and soffit framing, including movement allowances under maximum ambient temperature change.\"}]","Cold-Formed Metal Framing - Section 05 40 00 | PDF",1792830763,25]