[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-402241-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-402241-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","clik-fix-picccentral-securement-read-carefully-before-use","CLIK-FIX - PICC/Central Securement - Read carefully before use","","CLIK-FIX is a single-use, sterile device intended to stabilize compatible PICC and central catheters. It provides step-by-step preparation, alignment, locking, strap securing, and pad adhesion to support consistent catheter positioning. The instructions include indications, contraindications, and adverse reactions, emphasizing skin safety and infection control. It also covers warnings such as avoiding direct application of alcohol or acetone on the device, routine inspection, and replacement at least every 7 days. A removal technique is provided to minimize skin trauma.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/healthcare/","Healthcare",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/clik-fix-picccentral-securement-read-carefully-before-use/402241/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/clik-fix-picccentral-securement-read-carefully-before-use/402241.png","ImageObject",300,407,{"name":42,"@type":43},"Fahsai","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-01","2026-09-27",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",7,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What is the purpose of the CLIK-FIX device?","Question",{"text":63,"@type":64},"CLIK-FIX PICC/Central securement is intended to stabilize compatible PICC and central catheters.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"When should the CLIK-FIX device be replaced?",{"text":68,"@type":64},"Replace the CLIK-FIX device at least every 7 days.",{"name":70,"@type":61,"acceptedAnswer":71},"What precautions are required during use and removal?",{"text":72,"@type":64},"Follow facility protocol and universal blood/body fluid precautions. Minimize manipulation and movement of the catheter during application and removal, and avoid stretching the skin during removal to reduce skin trauma.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},402241,1790765890,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":107,"slug":108},40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":55,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":26,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":143,"read_time":97,"preview_page_count":4},549768702563,"https://ap-avatar.wpscdn.com/avatar/8000c4aa63b76e948b?x-image-process=image/resize,m_fixed,w_180,h_180&k=1786536092046926083","PREP AND PLACE: ALIGN TOP: SLOT ON STRAP: CLICK TO LOCK: SECURE STRAP: PEEL AND PRESS:  \nPrep securement area according to facility protocol. Remove release paper on the topside of the device. Orient the Clik-FIX device so the green arrows point towards the insertion site. Place the Clik-FIX device under the wing of the catheter as shown.  \nTurn to learn more  \n1  \nLightly fold the top of the locking mechanism over the wing of the catheter while pushing it slightly forward in the direction of the green arrows. This creates the space required to align the slot on the top onto the strap. The securement strap should be in the vertical position as shown.  \nTurn to learn more  \n2  \nWith the securement strap up in the vertical position, lightly push the top back toward the strap aligning the slot on the top of the locking mechanism up with the securement strap until the strap is in the slot.  \nTurn to learn more  \n3  \nWhen the securement strap is in the slot, place index finger under the device and thumb on corner of the top where the strap and the slot mate. Push the top downward until you hear a “click”.  \nTurn to learn more  \n4  \nAfter the locking mechanism has been activated, fold the securement strap over and slightly move it forward in the direction of the green arrows. Slide the securement strap under the securement strap holder located on the top of the device.  \nTurn to learn more  \n5  \nRemove the center split release paper from the underside of the device one side at a time. Lightly press down on the surface of the Clik-FIX to assure hold to the patient’s skin.  \nTurn to learn more  \n6  \nCLIK-FIX ™  \nPICC/Central Securement  \nClik-FIX ™ Catheter Securement  \n-Read carefully before use  \nThe Clik-FIX device is:  \n􀁸 Single Use Only  \n􀁸 Rx only  \n􀁸 Sterile when packaged in sealed sterile pouch or when included as a component is a sterile kit  \nIndications: Clik-FIX PICC/Central securement is intended to stabilize compatible PICC and Central Catheters.  \nContraindications:  \nDo not use device on compromised skin i.e. , open wounds, burns, lesions, rash , other irritation and/or patient’s with known tape or adhesive allergies or hypersensitive skin.  \nAdverse Reactions: Skin irritation  \nNote: Adhere Clik-FIX pad after x-ray confirmation of catheter position. Adhesive strip may be applied for added security during dressing changes.  \nWarning and Pre-Cautions:  \n􀁸 Follow facility protocol when placing and removing the device, observe universal blood and body fluid precautions and infection control guidelines.  \n􀁸 Do not use the Clik-FIX device on patient’s who are allergic to adhesives and on non-adherentskin.  \n􀁸 Do not apply alcohol, acetone or other liquid agent directly on the Clik-FIX when in use. These agents can weaken the device.  \n􀁸 During application and removal of the Clik-FIX device take care to minimize manipulation and movement of the catheter.  \n􀁸 Prepare skin surface according to facility protocol. Remove oil and moisture from application area.  \n􀁸 Routinely inspect the Clik-FIX device and catheter position.  \n􀁸 Replace the Clik-FIX device at least every 7 days.  \nClik-FIX is a trademark of Starboard Medical. Inc.  \nTips for easy use:.  \nTIP: Orient the device so the green arrows on the pad are pointing toward the insertion site.  \nTIP: Fold the strap up and keep it in the vertical position. Do not bend the strap.  \nTIP: Slightly move the top of locking mechanism forward in the direction of the green arrows to align slot to strap.  \nTips for easy use:  \nTIP: After aligning the slot on the strap, lightly push the top of the locking mechanism back towards the strap. Push down to “click” secure.  \nTIP: Follow facility protocol after placement of device, place Chlorhexidine disc, transparent dressing and date and time the dressing.  \nRemoval Technique:  \nDuring removal procedure do not stretch the skin. Stabilize the skin while peeling the pad away to reduce skin trauma.  \n1. Following facility protocol, carefully re","cbCaijzcFEFTheQ8","https://ap.wps.com/l/cbCaijzcFEFTheQ8","pdf",422923,"English","# Prep and place\n## Locking mechanism activation\n## Strap securement and pad adhesion\n# Indications and contraindications\n## Warnings and pre-cautions\n# Removal technique","[{\"question\":\"What is the purpose of the CLIK-FIX device?\",\"answer\":\"CLIK-FIX PICC/Central securement is intended to stabilize compatible PICC and central catheters.\"},{\"question\":\"When should the CLIK-FIX device be replaced?\",\"answer\":\"Replace the CLIK-FIX device at least every 7 days.\"},{\"question\":\"What precautions are required during use and removal?\",\"answer\":\"Follow facility protocol and universal blood/body fluid precautions. Minimize manipulation and movement of the catheter during application and removal, and avoid stretching the skin during removal to reduce skin trauma.\"}]","CLIK-FIX - PICC/Central Securement - Read carefully before use | PDF",1790528260]