[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-641880-105":59,"doc-detail-641880-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","class-72-elevator-starter-set-up-guide","Class 72 Elevator Starter Set-up Guide","","Class 72 Elevator Starter Set-up Guide describes installation planning and safe setup steps for a Siemens elevator starter system. It emphasizes reading the manual before wiring and installation, outlines special features such as an LCD with RMS current/voltage display, fault messaging, and parameter access, and explains operating options like selectable stall prevention modes and adjustable current limits. It also provides starter selection tables for In Delta and In Line configurations across specified voltage ranges, including rated current, overload, current limit ranges, and catalog numbers, along with key configuration and maintenance topics.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/class-72-elevator-starter-set-up-guide/641880/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/class-72-elevator-starter-set-up-guide/641880.png","ImageObject",300,407,{"name":92,"@type":93},"Supernature","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-26","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What special features does the Class 72 elevator starter provide?","Question",{"text":112,"@type":113},"It includes a 16-character by 2-line backlit LCD that shows true RMS currents and voltages, plus fault messages and parameter settings. It also provides an easy-to-use keypad for setting parameters and navigating information and fault menus.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How does selectable stall prevention work in this starter?",{"text":117,"@type":113},"The starter supports user-selectable stall prevention modes: Dynamic (based on average start time), Instantaneous (detects stall and reacts immediately), and Time Based.",{"name":119,"@type":110,"acceptedAnswer":120},"What information is included in the starter selection tables?",{"text":121,"@type":113},"The tables list starter ratings by configuration (In Delta or In Line) and voltage range, including HP at specified voltages, rated current, overload range, current limit range, and the manufacturer catalog number.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},641880,1793052254,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},962093270004,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","Class 72 Elevator Starter Set-up Guide  \nCongratulations, you have just purchased the most advanced, full-featured Elevator Starter available. While this product contains several features to aid in set up, it is important to read and understand this manual before attempting to install. As the set up and wiring of this version is quite different from previous versions of Siemens Elevator Starters, it is equally important to read even if you have a good working knowledge of the 72E version. If questions arise, additional help is available by calling your local Siemens Sales Office. A list of these offices can be found on our website [at www.sea.siemens.com/controls](at www.sea.siemens.com/controls).  \nSpecial Features:  \n16 Character by 2 Line Backlit Liquid Crystal Display:  \nDisplays true RMS Currents for motor and line amps  \nDisplays true RMS Voltages for the incoming line power.  \nDisplays Fault Messages and Parameter settings.  \nEasy to use Keypad:  \nSet starter parameters  \nScroll through Information and Fault Menus  \nSelectable Stall Prevention:  \nUser selectable: Dynamic, based upon average start time; Instantaneous, senses stall condition and reacts immediately; or Time Based.  \nAdjustable Current Limit:  \nAllows precise control during starting.  \nTable of Contents  \nSpecial Features: ........................................................................................................................... 3  \nStarter Selection ............................................................................................................................ 4  \nFeatures Overview: ....................................................................................................................... 6  \nControl Power Connections:........................................................................................................ 7  \nMotor Connections: .................................................................................................................... 10  \nInside Delta Motor Wiring......................................................................................................... 10  \nIn Line Motor Wiring:................................................................................................................ 12  \nLCD Menu ................................................................................................................................... 13  \nBasic Configuration of Your Siemens Elevator Starter using The Parameter Menu .......... 15  \nStarter Reset ................................................................................................................................ 15  \nElectrical Specifications.............................................................................................................. 16  \nMaintenance and Troubleshooting............................................................................................ 18  \nIMPORTANT  \nThese instructions do not purport to cover all details or variations in equipment, or to provide for every possible contingency to be met in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, the matter should be referred to the local Siemens office. The contents ofthis manual shall not become part of or modify any prior or existing agreement, commitment, or relationship. The warranty contained in the contract between the parties is the sole warranty of Siemens Energy & Automation, Inc. Any statements contained hereindo not create new warranties or modify the existing warranty.  \n________________________________________________________________________________  \nStarter Selection  \nTable 1: In Delta, 200 – 460 Volt starter ratings  \n\n|  | HP @ | HP @ | HP @ | Rated | Overload | Current Limit | Manufacturer |\n| --- | --- | --- | --- | --- | --- | --- | --- |\n|  | 200V | 230V | 460V | Current","cbCaijUZVvZDOuNY","https://ap.wps.com/l/cbCaijUZVvZDOuNY","pdf",443024,23,"English","# Special Features\n## 16 Character by 2 Line Backlit Liquid Crystal Display\n## Easy to use Keypad\n## Selectable Stall Prevention\n## Adjustable Current Limit\n# Starter Selection\n## In Delta, 200 – 460 Volt starter ratings\n## In Delta, 460-575 Volt starter ratings\n## In Line, 200 – 460 Volt starter ratings\n# Control Power Connections\n# Motor Connections\n# LCD Menu\n# Basic Configuration of Your Siemens Elevator Starter using The Parameter Menu\n# Starter Reset\n# Electrical Specifications\n# Maintenance and Troubleshooting","[{\"question\":\"What special features does the Class 72 elevator starter provide?\",\"answer\":\"It includes a 16-character by 2-line backlit LCD that shows true RMS currents and voltages, plus fault messages and parameter settings. It also provides an easy-to-use keypad for setting parameters and navigating information and fault menus.\"},{\"question\":\"How does selectable stall prevention work in this starter?\",\"answer\":\"The starter supports user-selectable stall prevention modes: Dynamic (based on average start time), Instantaneous (detects stall and reacts immediately), and Time Based.\"},{\"question\":\"What information is included in the starter selection tables?\",\"answer\":\"The tables list starter ratings by configuration (In Delta or In Line) and voltage range, including HP at specified voltages, rated current, overload range, current limit range, and the manufacturer catalog number.\"}]","Class 72 Elevator Starter Set-up Guide | PDF",1792718577,58]