[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-505664-105":59,"doc-detail-505664-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","choosing-flow-monitors-for-cems-applications","Choosing flow monitors for CEMS applications","","Electric power plants must reduce sulfur dioxide and nitrous oxides emissions under U.S. Clean Air Act Amendments, with the EPA requiring continuous emissions monitoring systems (CEMS) for designated Phase I and Phase II facilities. The rules allocate SO₂ and NOx allowances, define penalties and credit trading, and set detailed monitoring and reporting intervals. A key selection factor is how nonuniform flow affects CEMS accuracy, analyzed across differential pressure, ultrasonic, and thermal flow monitor methods.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/choosing-flow-monitors-for-cems-applications/505664/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/choosing-flow-monitors-for-cems-applications/505664.png","ImageObject",300,407,{"name":92,"@type":93},"dbqoiu","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-10","2026-10-04",true,{"@type":102,"interactionType":103,"userInteractionCount":44},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Why must a flow monitor be included in CEMS systems?","Question",{"text":112,"@type":113},"Nonuniform flow can affect the accuracy of continuous emissions monitoring. The document states a flow monitor must be included in systems that monitor dw/dt to address this impact.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What monitoring data cadence and reporting are required for SO2 emissions?",{"text":117,"@type":113},"Operators must record SO2 data points at least every 15 minutes, report hourly averages, and determine compliance using the sum of hourly mass emissions over the year.",{"name":119,"@type":110,"acceptedAnswer":120},"What performance specifications and testing do EPA require for CEMS flow monitors?",{"text":121,"@type":113},"EPA performance specs cover differential pressure, ultrasonic, and thermal methods, plus requirements for locating monitors away from disturbances. Flow monitors must properly span monthly average flow and undergo periodic Relative Accuracy Test Audits (RATAs) with relative accuracy limits shown in a table.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},505664,1791366974,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":44,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":29,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144,"preview_page_count":19,"preview_urls":145},3985747862462,"https://ap-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","As a result of the 1990 Clean Air Act Amendments¹,electricpower plants must reduce their emissions of sulfur dioxideand nitrous oxides-the primary causes of acid rain.TheU.S.Environmental Protection Agency(EPA),in its pro-osed rules²,designates the 111 Phase I fossil-fueled plantsroughly 268 boiler units)that must have continuous emis-sions monitoring systems(CEMS)installed,certified andoperational by November 15,1993.The EPA also designatesthe 662 Phase II plants(roughly 2,200 boiler units)thathave a January 1,1995 deadline.  \nUnder the rules,each plant is assigned an SO₂and NOxmass emissions allowance in tons per year.One allowanceauthorizes the emission of one ton(20001bm)of SO₂peryear.Plants that exceed their allowances are fined $2000for each excess ton per year.  \nPlants that release less than their annual allowance re-ceive one credit per ton of SO₂.Through an emissions credittrading market,utilities can sell or trade their credits toplants exceeding their allowances.At this writing,the esti-mated market value of each credit is $300 to $500.  \nPlant operators must monitor SO₂emissions continuous-ly,recording a data point at least every 15 minutes.Eachplant must report the hourly average of SO₂emissions,andcompliance with the annual allowance is determined fromthe sum of the hourly mass emissions over a year.  \nTo monitor SO₂mass emissions dw/dt(lIbm/h),the opera-tor must monitor both the SO₂concentration C(lbm/scf)and the mass flow rate Q(scf/h)of the stack gas,because:  \ndw/dt =CQ  \nTable 1:EPA's frequency of RATAs  \nReprinted from  \n# Choosingflow monitorsfor CEMSapplications\n\nFebruary.1993  \nA key factor in the selection process is the effect of nonuniform flowson the accuracy of the continuous emissions monitoring system.  \nJohn G.Olin,Ph.D.  \nPresident and CEO  \nSierra Instruments Inc.  \nMonterey,CA 93940  \nThis means that a flow monitor must now be included insystems that monitor dw/dt.Called continuous emissionsmonitoring systems(CEMS),these systems consist of:  \n● A sampling probe,  \n● Gas analyzers for SO₂and NOx,  \n● Opacity meter and flow monitor,  \n● Data acquisition and handling system.  \nThe accuracy and reliability of the CEMS is far more criticalthan conventional emissions instrumentation packages be-cause this system becomes something of a money meter-ameter that determines either the amount of a fine or,hope-fully,savings in the bank.  \nThe following will analyze the performance of differentialpressure,ultrasonic,and thermal flow monitors in threetypical continuous emissions monitoring locations,all ofwhich are characterized by nonuniformities in velocity pro-file and,in some instances,temperature.To help the plantoperator choose the right flow monitor for a given CEMS ap-plication,an analysis is presented of the errors in accuracyof the three flow monitors when deployed side by side at thethree CEMS locations.  \n## EPA's specifications for flow monitors\n\nThe EPA uses performance specs²for CEMS flow moni-tors and describes three basic instrumental methods:  \n● Differential pressure(△P),  \n● Ultrasonic(△t),and  \n● Thermal(△T).  \nAccording to the rules,CEMS flow monitors must be lo-cated at least 2.0 diameters from an upstream flow distur-bance,such as an elbow,expansion,or contraction,and atleast 0.5 diameters from a similar downstream disturbance.Meeting this criterion in stack locations is usually easy.However,in the duct work leading to the stack,it is oftenimpossible,and the operator must apply to EPA for a specialcertification.  \n\n| Results of Previous RATA Test   |  | Frequency   |\n| --- | --- | --- |\n| Before  \u003Cbr>Jan 1,2000   | After  \u003Cbr>Jan 1,2000   |  |\n| ±15.0%   | ±10.0%   | Semi-Annual   |\n| ±10.0%   | ±7.5%   | Annual   |\n\nAll flow monitors must properly span the monthly aver-age flow rate,but this isn't a problem with digital electron-ics.In addition,all flow monitors must undergo periodicRelative Accuracy Test Audits(RATAs).During these au-  \nAIR POLLUTION  \nSENSING &MONITORING  \ndits,t","cbCaivw64op9S2DO","https://ap.wps.com/l/cbCaivw64op9S2DO","pdf",3938011,"English","# Choosing flow monitors for CEMS applications\n## EPA's specifications for flow monitors","[{\"question\":\"Why must a flow monitor be included in CEMS systems?\",\"answer\":\"Nonuniform flow can affect the accuracy of continuous emissions monitoring. The document states a flow monitor must be included in systems that monitor dw/dt to address this impact.\"},{\"question\":\"What monitoring data cadence and reporting are required for SO2 emissions?\",\"answer\":\"Operators must record SO2 data points at least every 15 minutes, report hourly averages, and determine compliance using the sum of hourly mass emissions over the year.\"},{\"question\":\"What performance specifications and testing do EPA require for CEMS flow monitors?\",\"answer\":\"EPA performance specs cover differential pressure, ultrasonic, and thermal methods, plus requirements for locating monitors away from disturbances. Flow monitors must properly span monthly average flow and undergo periodic Relative Accuracy Test Audits (RATAs) with relative accuracy limits shown in a table.\"}]","Choosing flow monitors for CEMS applications | PDF",1791152904,15,[146,150,154,158],{"page_no":8,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/82371e4033b89b12e3e36f50fd525570.webp",983,1337,{"page_no":14,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/768f1702ec293e48a2f089c0e0db8c8b.webp",982,1331,{"page_no":81,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/35d6a13feddd3f2a014ffa6a592500f4.webp",981,1377,{"page_no":19,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/1b2e0254ef9237d56998620a6d321b23.webp",980,1368]