[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-661977-105":59,"doc-detail-661977-en":129},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":122,"head_meta":124,"extra_data":126,"updated_unix":128},105,"en","charm-rosa-tetracycline-sl-dilution-confirmation-test-flow-chart-tet-sl-004-initial-assay","Charm ROSA - Tetracycline-SL (Dilution Confirmation) Test Flow Chart - TET-SL-004 - Initial Assay","","Flow chart for the Charm ROSA® Tetracycline-SL (Dilution Confirmation) test (Initial Assay TET-SL-004), covering detection of tetracycline, chlortetracycline, and oxytetracycline in raw milk. Includes step-by-step instructions for verifying incubator temperature, adding a measured 300 μL sample, incubating for 8 minutes, and reading results in the Charm EZ® or ROSA Pearl Reader (read-only). Provides interpretation of negative versus positive outcomes and guidance for initial positive escalation and further testing.",{"@graph":69,"@context":121},[70,84,104],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/charm-rosa-tetracycline-sl-dilution-confirmation-test-flow-chart-tet-sl-004-initial-assay/661977/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":98,"encodingFormat":97,"isAccessibleForFree":99,"interactionStatistic":100},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/charm-rosa-tetracycline-sl-dilution-confirmation-test-flow-chart-tet-sl-004-initial-assay/661977.png","ImageObject",300,407,{"name":92,"@type":93},"Aditya","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-28",true,{"@type":101,"interactionType":102,"userInteractionCount":4},"InteractionCounter",{"@type":103},"ViewAction",{"@type":105,"mainEntity":106},"FAQPage",[107,113,117],{"name":108,"@type":109,"acceptedAnswer":110},"What analytes does the Charm ROSA Tetracycline-SL (Dilution Confirmation) test detect?","Question",{"text":111,"@type":112},"It detects tetracycline, chlortetracycline, and oxytetracycline drugs.","Answer",{"name":114,"@type":109,"acceptedAnswer":115},"What are the key timing and temperature steps in the test procedure?",{"text":116,"@type":112},"Verify incubator temperature is 56 ± 1 °C, incubate the test for 8 minutes (not more than 9 minutes), then read results within 5 minutes using the specified reader.",{"name":118,"@type":109,"acceptedAnswer":119},"How should a positive initial result be handled?",{"text":120,"@type":112},"For a positive initial result, refer to the specified page/consult the Charm 2400 form and contact the State Lab Evaluation Officer or Charm Sciences technical support for assistance.","https://schema.org",{"og:url":83,"og:type":123,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":125,"canonical":83},"index,follow",{"doc_id":127,"site_id":62},661977,1793192224,{"code":4,"msg":5,"data":130},{"doc_id":127,"user_id":131,"nickname":92,"user_avatar":132,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":4,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":81,"language":138,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":139,"faqs":140,"seo_title":141,"seo_description":67,"update_tm":128,"read_time":39},962085564549,"https://ap-avatar.wpscdn.com/davatar_085a072bc5b1113ac321206ff7593b45","|  | Charm ROSA® Tetracycline-SL (Dilution Confirmation) Test Flow Chart \u003Cbr>Initial Assay TET-SL-004 |  |  |  |  |  | C\u003Cbr>T\u003Cbr>\u003Cbr>| | | | Results in 8 Minutes |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n|  |  |  |  |  |  |  |  | |  |  |  |  |\n|  | Detects:\u003Cbr>Tetracycline, Chlortetracycline, and Oxytetracycline Drugs |  |  |  |  |  |  |  |  |  |  |  |\n| Test Procedure | | (1) Peel Strip\u003Cbr>Verify incubator temperature is\u003Cbr>56 ± 1 °C.\u003Cbr>Shake sample and label test strip. Place strip in incubator and peel tape back to “Peel to Here” line. |  | \u003Cbr>\u003Cbr>| (2) Add Raw Milk Sample\u003Cbr>Slowly pipet 300 μL sample into sample compartment at incubator indicator line (as shown) .\u003Cbr>Reseal tape over sample compartment. Close lid and latch and incubate for 8 minutes, but not more than 9 minutes. |  |  | |  |  |  | (3) Incubate\u003Cbr>Remove tests from incubator.\u003Cbr>Visually inspect for even development.\u003Cbr>Within 5 minutes insert clean and visually valid test strip in Charm EZ® system or ROSA Pearl Reader in Read-only mode. |\n|  | (4) Read Results\u003Cbr>Ex. of Charm EZ Screen\u003Cbr>|  | Ex. of ROSA Pearl Reader\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>TETR\u003Cbr>DATE: 06/12/2017\u003Cbr>SAMPLE: 4256\u003Cbr>OPERATOR: CHARM SCIENCES\u003Cbr>READING:-1075\u003Cbr>RESULTS: NEGATIVE\u003Cbr>ROSA Pearl Reader |  |  | \u003Cbr>Ex. of ROSA Reader Versions 1.05 and higher\u003Cbr>\u003Cbr>\u003Cbr>TETR\u003Cbr>DATE: 06/12/2017\u003Cbr>SAMPLE: 4256\u003Cbr>OPERATOR: CHARM SCIENCES\u003Cbr>READING:-1075\u003Cbr>RESULTS: NEGATIVE\u003Cbr>ROSA Reader |  |  |  |  |  |  |\n|  | Read using Charm EZ System, ROSA Pearl Reader or Rosa Reader version 1.05 or higher. Refer to manual for complete directions.\u003Cbr>\u003Cbr>Results:\u003Cbr>Negative-NOT FOUND-No tetracyclines detected. No further testing required. | Positive- Initial Positive-Refer to page 3 or consult with Charm 2400 form. Contact State Lab Evaluation Officer or Charm Sciences technical support for assistance. |  |  |  |  |  |  |  |  |  |  |  |\n\nPage 1  \n659 Andover Street, Lawrence, MA 01843-1032, USA  \nT +1 .978.687.9200 | F +[1.978.687.9216 | E info@charm.com | www.charm.com](1.978.687.9216 | E info@charm.com | www.charm.com)[ ](1.978.687.9216 | E info@charm.com | www.charm.com)MRK-1185-003 Jun-2017  \n© 2017 Charm Sciences, Inc. Charm, Charm EZ, and ROSA are registered trademarks, and test strip product packaging is trade dress, of Charm Sciences, Inc.  \n|  | Charm ROSA® Tetracycline-SL (Dilution Confirmation) Test Flow Chart\u003Cbr>Control Preparation and Daily Performance Monitoring\u003Cbr>TET-SL-004 \u003Cbr>\u003Cbr>CT\u003Cbr>|  |  | Results in 8 Minutes |  |\n| --- | --- | --- | --- | --- | --- |\n|  | Detects:\u003Cbr>Tetracycline, Chlortetracycline, and Oxytetracycline Drugs |  |  |  |  |\n| Controls | NEGATIVE CONTROL POSITIVE CONTROL |  |  |  | \u003Cbr>Refrigerate or put on ice for\u003Cbr>5 minutes |\n|  | | 5 mL\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>| |  |  |\n|  | Previously tested tetracycline negative milk, which has previously yielded results of-600 or more negative. | Reconstitute 3 tablets with 5 mL Negative Control (raw milk) shake thoroughly and let sit for 5 minutes refrigerated or on ice. Shake thoroughly prior to testing. |  |  |  |\n|  | If using ROSA Reader Versions 1.05 and higher, or ROSA Pearl Reader, use ESC 5 reader function to enter Performance Monitoring Mode. Use left or right arrow to toggle from Beta-lactam to TETR channel. Refer to manual for complete directions.\u003Cbr>The reader will prompt for the calibrators and controls.\u003Cbr>1.\u003Cbr>4.\u003Cbr>\u003Cbr>TETR\u003Cbr>DATE: 06/12/2017\u003Cbr>SAMPLE: PERF TEST\u003Cbr>OPERATOR: CHARM SCIENCES\u003Cbr>2.\u003Cbr>\u003Cbr>TETR\u003Cbr>DATE: 06/12/2017\u003Cbr>SAMPLE: LOWCAL\u003Cbr>OPERATOR: CHARM SCIENCES\u003Cbr>READING: -0272\u003Cbr>RESULTS: IN RANGE\u003Cbr>\u003Cbr>3. TETR\u003Cbr>DATE: 06/12/2017\u003Cbr>SAMPLE: HIGHCAL\u003Cbr>OPERATOR: CHARM SCIENCES\u003Cbr>READING: 450\u003Cbr>RESULTS: IN RANGE\u003Cbr>Press ENTER to start. Insert Low Calibrator, press ENTER. Insert High Calibrator, press ENTER.\u003Cbr>\u003Cbr>TETR\u003Cbr>DATE: 06/12/2017\u003Cbr>SAMPLE: NEGATIVE CONTROL\u003Cbr>OPERATOR: CHARM SCIENCES\u003Cbr>READING:-1075\u003Cbr>RESULTS: VALID\u003Cbr>Insert Negative Control, p","cbCaiqGZtqSDr07A","https://ap.wps.com/l/cbCaiqGZtqSDr07A","pdf",1905161,"English","# Test Procedure\n## Add Raw Milk Sample\n## Incubate and Read Results\n# Results Interpretation\n## Negative\n## Positive","[{\"question\":\"What analytes does the Charm ROSA Tetracycline-SL (Dilution Confirmation) test detect?\",\"answer\":\"It detects tetracycline, chlortetracycline, and oxytetracycline drugs.\"},{\"question\":\"What are the key timing and temperature steps in the test procedure?\",\"answer\":\"Verify incubator temperature is 56 ± 1 °C, incubate the test for 8 minutes (not more than 9 minutes), then read results within 5 minutes using the specified reader.\"},{\"question\":\"How should a positive initial result be handled?\",\"answer\":\"For a positive initial result, refer to the specified page/consult the Charm 2400 form and contact the State Lab Evaluation Officer or Charm Sciences technical support for assistance.\"}]","Charm ROSA - Tetracycline-SL (Dilution Confirmation) Test Flow Chart - TET-SL-004 - Initial Assay | PDF"]