[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-663185-105":59,"doc-detail-663185-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","chargepoint-cpf50-wall-mount-typical-single-line-diagram-software-services","ChargePoint CPF50 Wall Mount - Typical Single Line Diagram - Software & Services","","Typical level 2 EV charging station-wall mount configuration with cable management, including circuit-level power management requirements via ChargePoint software aligned to NEC 625.42. Provides CPF50 wiring diagram components and legend covering AC power feed, ethernet, SAE J1772 connector, cellular and WiFi connectivity, ChargePoint cloud services, and SAE J3400 (NACS) connector. Includes general installation and overcurrent protection notes, licensing requirements, and guidance on required ChargePoint cloud plans with power, essential, and community options per charging port.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/chargepoint-cpf50-wall-mount-typical-single-line-diagram-software-services/663185/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/chargepoint-cpf50-wall-mount-typical-single-line-diagram-software-services/663185.png","ImageObject",300,407,{"name":92,"@type":93},"Sarah ","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":8},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What connectivity options and connectors are listed for the CPF50 charging station?","Question",{"text":112,"@type":113},"The diagram legend includes an ethernet connection, 4G LTE cellular connection, WiFi connection, an SAE J1772 connector, and an SAE J3400 (NACS) connector.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What installation and sizing requirements are stated in the general notes?",{"text":117,"@type":113},"Overcurrent protection devices, conductors, and conduit sizes are provided by ChargePoint for reference only; site-specific wire sizing must be performed by the installation contractor based on local conditions and codes. Products must be installed by a licensed contractor with ChargePoint installer certifications.",{"name":119,"@type":110,"acceptedAnswer":120},"Which cloud plan is required for CPF50 stations and what are the main plan types?",{"text":121,"@type":113},"All CPF50 stations require an active ChargePoint cloud plan, with a power, community, or essential cloud plan required per charging port. The power plan is recommended for access-controlled lots and does not support paid charging; the essential plan targets multifamily properties with paid charging; the community plan is recommended for shared charging spaces.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},663185,1793225669,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":8,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":8,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":81},962085320529,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","TYPICAL LEVEL 2 EV CHARGING STATION-WALL MOUNT WITH CABLE MANAGEMENT  \nREQUIRES CIRCUIT-LEVEL POWER MANAGEMENT VIA CHARGEPOINT SOFTWARE PER NEC 625.42  \nCPF50 WIRING DIAGRAM  \nLEGEND  \nAC POWER FEED FROM DISTRIBUTION (3) CONDUCTORS, 6 AWG OR 8 AWG  \nETHERNET CONNECTION  \nSAE J1772 CONNECTOR  \n4G LTE CELLULAR CONNECTION  \nWIFI CONNECTION  \nCHARGEPOINT CLOUD SERVICES  \nSAE J3400 (NACS) CONNECTOR  \nGENERAL NOTES  \n1. ALL OVERCURRENT PROTECTION DEVICES, CONDUCTORS, AND CONDUIT SIZES PROVIDED ON THIS DRAWING ARE PROVIDED BY CHARGEPOINT FOR REFERENCE ONLY. SITE SPECIFIC WIRE SIZING SHALL BE PERFORMED BY THE INSTALLATION CONTRACTOR TAKING INTO ACCOUNT LOCAL CONDITIONS AND CODES / STANDARDS.  \n2. CHARGEPOINT PRODUCTS TO BE INSTALLED BY A LICENSED CONTRACTOR WITH CHARGEPOINT INSTALLER CERTIFICATIONS.  \n3. FOR MORE INFORMATION ABOUT CHARGEPOINT'S CPF50 LEVEL 2 AC CHARGER, REFER TO THE FOLLOWING LINKS:  \n● CPF50 DATASHEET: [https://docs.chargepoint.com/ref-docs-sec/content/pdfs/2-ac/cpf50/cpf50-multifamily-ds.pdf](https://docs.chargepoint.com/ref-docs-sec/content/pdfs/2-ac/cpf50/cpf50-multifamily-ds.pdf)  \n● CPF50 SITE DESIGN GUIDE: [https://docs.chargepoint.com/ref-docs-sec/content/pdfs/2-ac/cpf50/cpf50-sdg.pdf](https://docs.chargepoint.com/ref-docs-sec/content/pdfs/2-ac/cpf50/cpf50-sdg.pdf)  \n● INSTALLATION GUIDES AVAILABLE TO CERTIFIED INSTALLERS: [https://www.chargepoint.com/partners/training-certification](https://www.chargepoint.com/partners/training-certification)  \n[SOFTWARE & SERVICES](SOFTWARE & SERVICES)  \nCHARGEPOINT CLOUD PLANS  \nALL CPF50 STATIONS REQUIRE AN ACTIVE CHARGEPOINT CLOUD PLAN. A POWER, COMMUNITY OR ESSENTIAL CLOUD PLAN IS REQUIRED PER CHARGING PORT.  \nADDITIONAL SOFTWARE OPTIONS AVAILABLE FOR FLEETS. CONTACT YOUR CHARGEPOINT REPRESENTATIVE FOR MORE INFORMATION.  \nPOWER PLAN  \nCPCLD-POWER-n*  \nRECOMMENDED FOR ACCESS-CONTROLLED LOTS  \n(E.G. ELECTRIFIED FLEETS, AUTO DEALERSHIPS, ETC. ) . PAID CHARGING NOT SUPPORTED.  \nESSENTIAL PLAN  \nCPCLD-ESSENTIAL  \nRECOMMENDED FOR MULTIFAMILY PROPERTIES (OR SIMILAR) WITH ACCESS-CONTROLLED OR SEMI-PUBLIC LOTS  \nREQUIRES PAID CHARGING  \nNO UP FRONT COSTS, NO TERM LENGTH  \nCOMMUNITY PLAN CPCLD-COMMUNITY-n*  \nRECOMMENDED FOR MULTIFAMILY PROPERTIES (OR SIMILAR) WITH SHARED CHARGING SPACES.  \n*REPLACE \"n\" WITH DESIRED YEARS OF SERVICE (1, 2, 3, 4, OR 5 YEARS)  \nFOR INFORMATION ON POWER, COMMUNITY, AND ESSENTIAL CLOUD PLAN FEATURES, SEE TABLE BELOW AND VISIT:  \n[https://www.chargepoint.com/download-file/cp-cloud-plans-comparison-matrix-commercial](https://www.chargepoint.com/download-file/cp-cloud-plans-comparison-matrix-commercial)  \n| | \u003Cbr>GLOBAL HEADQUARTERS\u003Cbr>240 EAST HACIENDA AVENUE CAMPBELL, CA 95008\u003Cbr>TEL: +1 (408) 841-4500\u003Cbr>CONCEPT DRAWING NOT FOR CONSTRUCTION |\n| --- | --- |\n|  |  |\n| | DRAWING TITLE: CHARGEPOINT CPF50 WALL MOUNT\u003Cbr>TYPICAL SINGLE LINE DIAGRAM |\n|  |  |\n| | DOCUMENT \\#: 12105002c |\n|  | DATE: 08.04.25 |\n|  | DRAWN BY: CMT |\n|  | SCALE: N.T.S. |\n|  |  |\n|  | SHEET: |\n|  | EV501 |","cbCaikijr7LSx5Hf","https://ap.wps.com/l/cbCaikijr7LSx5Hf","pdf",484216,"English","# Legend\n## General Notes\n# Software & Services\n## ChargePoint Cloud Plans\n## Power Plan\n## Essential Plan\n## Community Plan","[{\"question\":\"What connectivity options and connectors are listed for the CPF50 charging station?\",\"answer\":\"The diagram legend includes an ethernet connection, 4G LTE cellular connection, WiFi connection, an SAE J1772 connector, and an SAE J3400 (NACS) connector.\"},{\"question\":\"What installation and sizing requirements are stated in the general notes?\",\"answer\":\"Overcurrent protection devices, conductors, and conduit sizes are provided by ChargePoint for reference only; site-specific wire sizing must be performed by the installation contractor based on local conditions and codes. Products must be installed by a licensed contractor with ChargePoint installer certifications.\"},{\"question\":\"Which cloud plan is required for CPF50 stations and what are the main plan types?\",\"answer\":\"All CPF50 stations require an active ChargePoint cloud plan, with a power, community, or essential cloud plan required per charging port. The power plan is recommended for access-controlled lots and does not support paid charging; the essential plan targets multifamily properties with paid charging; the community plan is recommended for shared charging spaces.\"}]","ChargePoint CPF50 Wall Mount - Typical Single Line Diagram - Software & Services | PDF"]