[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-463833-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-463833-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","characterization-of-a-100-nm-radfet-as-a-proton-beam-detector-research-report","Characterization of a 100 nm RADFET as a Proton Beam Detector - Research Report","","The RADFET VT06 from Varadis (Cork, Ireland), designed for high-dose applications in particular for spacecraft missions, is characterized using low- and high-energy proton beams at two facilities: the Accelerator National Centre in Sevilla (Spain) and the Paul Scherrer Institute in Villigen (Switzerland). Proton energies of 1, 2, 3, 150, and 230 MeV were tested with accumulated doses from 130 to 512 Gy, irradiating the device in unbiased mode while monitoring source voltage before and after irradiation for dosimetry.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/characterization-of-a-100-nm-radfet-as-a-proton-beam-detector-research-report/463833/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/characterization-of-a-100-nm-radfet-as-a-proton-beam-detector-research-report/463833.png","ImageObject",300,407,{"name":42,"@type":43},"dhado","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-07","2026-09-30",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",10,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What is the RADFET VT06 intended for in this study?","Question",{"text":63,"@type":64},"It is aimed at high-dose radiation measurement, mainly for spacecraft missions, and is evaluated as a proton-beam detector under controlled irradiation conditions.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"Which proton energies and dose ranges were used to characterize the device?",{"text":68,"@type":64},"The study uses proton energies of 1, 2, 3, 150, and 230 MeV with accumulated doses from 130 to 512 Gy.",{"name":70,"@type":61,"acceptedAnswer":71},"How were proton dose and device readout handled during irradiation?",{"text":72,"@type":64},"The RADFET was irradiated in unbiased mode, while the source voltage was measured before and after irradiation to monitor the delivered radiation dose.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},463833,1790993216,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,115,120,123,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":112,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":113,"slug":114},8,30,"research-report",{"id":116,"doc_module":4,"doc_module_name":25,"category_name":117,"show_sort_weight":118,"slug":119},9,"Religion & Spirituality",20,"religion-spirituality",{"id":118,"doc_module":4,"doc_module_name":25,"category_name":121,"show_sort_weight":118,"slug":122},"World Cup","world-cup",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":55,"slug":125},"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":112,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":145,"preview_page_count":33,"preview_urls":146},5909893218464,"https://ap-avatar.wpscdn.com/davatar_085a072bc5b1113ac321206ff7593b45","Article  \nCharacterization of a 100 nm RADFET as a Proton Beam Detector  \nJ. A. Moreno-Pérez 1, I. Ruiz-García 2, R. Duane 3, P. Martín-Holgado 4, L. Morvaj 5, N. Vasovic 3,  \nW. Hajdas 5, Y. Morilla 4 and M. A. Carvajal 1, *  \nAcademic Editor: Virginia Strati  \nReceived: 24 November 2025  \nRevised: 21 December 2025  \nAccepted: 24 December 2025  \nPublished: 27 December 2025  \nCopyright: © 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.  \n1 PRIMELab, ECsens, Sport and Health University Research Institute (iMUDS), Department of Electronics and Computer Technology, Research Centre for Information and Communications Technologies (CITIC), University of Granada, 18071 Granada, Spain; [juanantoniomp@ugr.es](juanantoniomp@ugr.es)  \n2 James Watt School of Engineering, University of Glasgow, Glasgow G12 8QQ, UK; [isidoro.ruizgarcia@glasgow.ac.uk](isidoro.ruizgarcia@glasgow.ac.uk)  \n3 Varadis, Site 13 Carrigaline Industrial Park, Carrigaline, P43 DC53 Cork, Ireland; [russell@varadis.com](russell@varadis.com) (R.D.); [nikola@varadis.com](nikola@varadis.com) (N.V.)  \n4 Centro Nacional de Aceleradores, Universidad de Sevilla, CSIC, JA, Avda. Tomás Alva Edison 7,  \n41092 Sevilla, Spain; [pmartinholgado@us.es](pmartinholgado@us.es) (P.M.-H.); [ymorilla@us.es](ymorilla@us.es) (Y.M.)  \n5 PSI Center for Neutron and Muon Sciences, PSI, 5232 Villigen, Switzerland; [ljiljana.morvaj@psi.ch](ljiljana.morvaj@psi.ch) (L.M.); [wojtek.hajdas@psi.ch](wojtek.hajdas@psi.ch) (W.H.)  \n* Correspondence: carvajal@ugr.es  \nAbstract  \nThe RADFET VT06 developed by Varadis (Cork, Ireland), which is aimed at high-dose applications, mainly for spacecraft missions, has been characterized by low-and highenergy proton beams at two different facilities, the Accelerator National Centre (Sevilla, Spain) and the Paul Scherrer Institute (PSI) located in Villigen (Switzerland), using a reader unit system developed by the University of Granada (Spain) . The devices have been characterized with proton energies of 1, 2, 3, 150, and 230 MeV, with accumulated doses from 130 to 512 Gy, where the RADFET was unbiased during the irradiation while the source voltage was measured before and after irradiation to monitor the radiation dose. Excellent linearity has been obtained with a minimum correlation factor R2 of 0.996, with a sensitivity that can vary from (0.691 ± 0.007) mV/Gy for 1 MeV to (1.143 ± 0.023) mV/Gy for 230 MeV without any build-up layer. An excellent stability was found in the studied cases, with dispersion being lower than 4% after a dose accumulation higher than 500 and 200 Gy for protons of 1 and 3 MeV, respectively. The detectors demonstrated linear responses, very low sensitivity dispersion per set of samples, and excellent stability after irradiation. This shows that, with an appropriate readout system, the RADFET can become an excellent system for high-dose proton beams.  \nKeywords: radiation detector; RADFET; unbiased; proton beams; dosimetry  \n1. Introduction  \nIonizing radiation is characterized by the creation of ion pairs in materials. These ionic pairs cause failures in electronic circuits, which can become permanent defects, and biological damage to the DNA of human and animals, which can produce tumours and death in extreme cases. Therefore, the detection of ionizing radiation and quantification of the energy delivered by the radiation is crucial in facilities with radiation sources such as particle accelerators, nuclear plants, and hospitals with radiotherapy services, among others. Therefore, in recent decades, different types of radiation detector have been developed, such as ionization chambers, thermoluminescent dosimeters (TLDs), radiochromic films,  \nand, especially, semiconductor detectors [1–3] . Semiconductor devices such as diodes or metal-oxide field effect transistors (MOSFETs) [4–7] have been used as ","cbCaimN28uegl4fE","https://ap.wps.com/l/cbCaimN28uegl4fE","pdf",2620494,11,"English","# Abstract\n# Introduction\n## Ionizing radiation and detector needs\n## MOSFET dosimetry and RADFET operation\n## Biased vs unbiased modes and fading effect","[{\"question\":\"What is the RADFET VT06 intended for in this study?\",\"answer\":\"It is aimed at high-dose radiation measurement, mainly for spacecraft missions, and is evaluated as a proton-beam detector under controlled irradiation conditions.\"},{\"question\":\"Which proton energies and dose ranges were used to characterize the device?\",\"answer\":\"The study uses proton energies of 1, 2, 3, 150, and 230 MeV with accumulated doses from 130 to 512 Gy.\"},{\"question\":\"How were proton dose and device readout handled during irradiation?\",\"answer\":\"The RADFET was irradiated in unbiased mode, while the source voltage was measured before and after irradiation to monitor the delivered radiation dose.\"}]","Characterization of a 100 nm RADFET as a Proton Beam Detector - Research Report | PDF",1790767227,28,[147,151,155,159],{"page_no":22,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/c3c2507782ab1e7199cce76e6ef5d992.webp",983,1390,{"page_no":26,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/358c22a694759de6b0176dcafd684206.webp",982,1388,{"page_no":30,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/d407d402a1995298519dc65e3e64a67c.webp",981,1387,{"page_no":33,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/8da513166d069ef4e9ee457a9b2be8d4.webp",980,1385]