[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-648478-105":59,"doc-detail-648478-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","chapter-iii-reference-drawings-concrete-and-romar-step-and-gravity-septic-tank-installations-april-2024","Chapter III - Reference Drawings - Concrete and Romar Step and Gravity Septic Tank Installations - April 2024","","Reference drawings for concrete and HDPE/Romar step and gravity septic tank installations are provided for Anne Arundel County, Maryland Department of Public Works. The index lists plan and section sheets for severe duty pressure and gravity systems, including riser and cover details, pipe trench bedding, pump simplex arrangements, pump one-line diagrams, electrical junction boxes, and valve/insert details. Drawing notes specify tracer wire, detection tape, electrical conduit and float wiring, sealing and backfill requirements, bedding aggregate standards, and clearance guidance for safe pump operation and maintenance.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/chapter-iii-reference-drawings-concrete-and-romar-step-and-gravity-septic-tank-installations-april-2024/648478/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/chapter-iii-reference-drawings-concrete-and-romar-step-and-gravity-septic-tank-installations-april-2024/648478.png","ImageObject",300,407,{"name":92,"@type":93},"Aditya","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-25","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What types of septic tank installations are covered by the reference drawing index?","Question",{"text":112,"@type":113},"The index includes severe duty pressure installations (HDPE step) and severe duty gravity installations (Romar SDG), along with supporting details such as risers, covers, and pipe trench bedding.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Which electrical components and layouts are referenced in the drawings?",{"text":117,"@type":113},"The drawings reference electrical junction boxes, PVC electrical conduits, conduit elbows, and one-line diagrams for pump power, including wiring callouts for float switches and pump power.",{"name":119,"@type":110,"acceptedAnswer":120},"What installation and sealing requirements are emphasized in the notes?",{"text":121,"@type":113},"The notes specify backfilling with clean sand within grading limits, providing bentonite around penetrations and seals, using geotextile materials with overlap, and using compression seals for pipe penetrations to ensure proper sealing.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},648478,1792878746,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":36},962085564549,"https://ap-avatar.wpscdn.com/davatar_085a072bc5b1113ac321206ff7593b45","| \u003Cbr>ANNE ARUNDEL COUNTY MARYLAND\u003Cbr>DEPARTMENT OF PUBLIC WORKS\u003Cbr>CHAPTER III\u003Cbr>REFERENCE DRAWINGS\u003Cbr>for\u003Cbr>CONCRETE AND ROMAR STEP AND GRAVITY SEPTIC TANK INSTALLATIONS |  |  |\n| --- | --- | --- |\n| | April 2024 | |\n\nPublished: 01/01 Revised: 04/24  \nREFERENCE DRAWINGS FOR  \nCONCRETE AND ROMAR STEP AND GRAVITY  \nSEPTIC TANK INSTALLATIONS  \nINDEX OF DRAWINGS  \nDESCRIPTION DRAWING NO.  \n1. Plan-HDPE Step Septic Tank Severe Duty, Pressure Installation SS-S-1a  \n2. Section-HDPE Step Septic Tank, Severe Duty, Pressure Installation SS-S-1b  \n3. Reference Step and Gravity Septic Tank Design Plan View SS-S-1c  \n4. Plan – Romar SDG Septic Tank, Severe Duty, Gravity Installation SS-S-2a  \n5. Section-Romar SDG Septic Tank Severe Duty, Gravity Installation SS-S-2b  \n6. Riser and Cover Detail for HDPE Tanks SS-S-3  \n7. Pipe Trench Bedding Detail SS-C-1  \n8. Septic Tank Simplex Pump System Typical Arrangement at Residence SS-E-1  \n9. One Line Diagram for Pumps ½ H.P. or Less (115V) SS-E-2  \n10. One Line Diagram for Pumps ½ [H.P. to 2 H.P](H.P. to 2 H.P). (230V) SS-E-3  \n11. Explosion Proof Junction Box SS-E-4  \n12. Quazite Composolite Enclosure SS-E-5  \n13. Curb Valve Detail SS-M-1  \n14. Pump Insert Detail SS-M-2  \nPublished: 01/01 Revised: 04/24  \n\n| RISER,\u003Cbr>SEE DETAIL SHEET NO. S-5\u003Cbr>\u003Cbr>PUMP INSERT SEE DETAIL, SHT. NO. M-2\u003Cbr>1 \u003Cbr>2\" STAINLESS STEEL CABLE CLAMPS (TYP.)\u003Cbr>1-1/2\"PVCTRUE UNION BALL VALVE\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>SUBMERSIBLE\u003Cbr>SEPTIC TANK EFFLUENT\u003Cbr>PUMP\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>4\" (TYP.)\u003Cbr>2\" POLYPROPYLENE ROPE\u003Cbr>~~ ~~SLEEVE ROPE THRU BLOCK (TYP.)\u003Cbr> (3)8\"x 8\"x 16\" CMU ATTACHED AS SHOWN\u003Cbr>(TYP.)\u003Cbr>\u003Cbr>\u003Cbr>1 \u003Cbr>1-1/2\" PVC ELECTRICAL CONDUIT\u003Cbr>1-1/2\"Ø SPR 21 PVC DISCHARGE PIPE\u003Cbr>JUNCTION BOX\u003Cbr>FLOAT ~~  ~~SWITCHES\u003Cbr>AASHTO NO.67 AGGREGATE ~~ ~~\u003Cbr>4\" PVC INLET\u003Cbr>4\" PVC CLEANOUT\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>6\"x4\" TEE\u003Cbr>\u003Cbr>\u003Cbr>|  |  |  |  |\n| --- | --- | --- | --- | --- |\n| | \u003Cbr>\u003Cbr>| | | |\n|  |  |  | |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n\n| |  |  |  |  | ELECTRICAL JUNCTION BOX (SEE DETAIL; SHT. E-4 & E-5)\u003Cbr>1 1/2\"PVC ELECTRICAL CONDUIT ELBOWS (SEE DETAIL E-5)\u003Cbr>\u003Cbr>EXTEND 6\" TO MATCH ELEV. OF COVER & PROVIDE PVC CAP\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>NEOPRENE COMPRESSION SEAL-TYP. ALL PIPE PENETRATIONS\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>BACKFILL WITH CLEAN SAND TO\u003Cbr>WITHIN 4\" OF GRADE\u003Cbr>\u003Cbr>ANCHOR SHALL\u003Cbr>BE WITHIN 10 FEET\u003Cbr>DISTANCE FROM BOTTOM OF TANK SHALL BE CENTERED\u003Cbr>PROVIDE BENTONITE AROUND ALL PENTRATIONSAND SEALS\u003Cbr>1.5\", CALL OUT DISTANCE TO DROP LINE TO 4' OF COVER\u003Cbr>\u003Cbr>GEOTEXTILE MATERIAL OVER TOP OF GRAVEL AND OVERLAP AT TANK AND GROUND\u003Cbr>A MINIMUM OF 1'-0\"\u003Cbr>(3)8\"x 8\"X 16\" CMU ATTACHED AS SHOWN\u003Cbr>1' AROUND TANK FOR STONE\u003Cbr>\u003Cbr>GRAVEL UNDER DISCHARGE PIPE\u003Cbr>1\u003Cbr>CONNECT TO OUTER PART OF RIB, ALLOWS GROMMET TO SEAL BETTER\u003Cbr>\u003Cbr>GEOTEXTILE MATERIAL OVER TOP OF GRAVEL\u003Cbr>METALLIC DETECTION TAPE &\u003Cbr>TRACER WIRE\u003Cbr>\u003Cbr>2\"\u003Cbr>\u003Cbr>~~ ~~ ADD WOOVEN GEOTEXTILE\u003Cbr>NOTES:\u003Cbr>PROVIDE TRACER WIRE BETWEEN TANK & R/W\u003Cbr>PROVIDE BALL VALVE |\n| --- | --- | --- | --- | --- | --- |\n| |  | |  | |  |\n| |  |  | |  |  |\n|  |  |  | \u003Cbr>| |  |\n| |  |  |  |  |  |\n\n\n| \u003Cbr>\u003Cbr>\u003Cbr>PROVIDE\u003Cbr>\u003Cbr>CLEARANCES ~~ ~~TO BE ABLE\u003Cbr>TO REMOVE AND OPERATE\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>|  |  |  |  |\n| --- | --- | --- | --- | --- |\n| NOTE: RISER CONDUIT PENETRATION FOR PUMP POWER AND FLOATS SHALL FALL WITHIN EITHER AREA \"A\" OR \"B\" IN ORDER TO AVOID INTERFERENCE WITH THE PUMP DISCHARGE PIPE AND TO PREVENT INTERFERENCE WITH PUMP DISCHARGE REMOVAL.\u003Cbr>|  |  |  |  |\n| | \u003Cbr>\u003Cbr>| | | |\n|  |  |  | |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n\n| \u003Cbr>SEPTIC TANK\u003Cbr>4\" PVC CLEANOU~~T ~~\u003Cbr>\u003Cbr>CORRUGATED POLYETHYLENE RISER (SEE DETAIL SHT. NO. S-6)\u003Cbr>EXCAVATION FOR ANTIFLOATATION DEVICE\u003Cbr>(TYP.)\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>6\" PVC PUMPOUT W/ CAP PER COUNTY STANDARD S/9\u003Cbr>1 \u003Cbr>2\" STAINLESS STEEL CABLE CLAMPS (TYP.) ~~ ~~\u003Cbr>4\" PVC OUTLET\u003Cbr>SCH 40 PVC  THROUGHOUT \u003Cb","cbCaicKXibIV4M1T","https://ap.wps.com/l/cbCaicKXibIV4M1T","pdf",648531,16,"English","# Index of Drawings\n## Plan and Section Drawings\n## Pumping, Electrical, and Valves Details\n## Notes and Installation Requirements","[{\"question\":\"What types of septic tank installations are covered by the reference drawing index?\",\"answer\":\"The index includes severe duty pressure installations (HDPE step) and severe duty gravity installations (Romar SDG), along with supporting details such as risers, covers, and pipe trench bedding.\"},{\"question\":\"Which electrical components and layouts are referenced in the drawings?\",\"answer\":\"The drawings reference electrical junction boxes, PVC electrical conduits, conduit elbows, and one-line diagrams for pump power, including wiring callouts for float switches and pump power.\"},{\"question\":\"What installation and sealing requirements are emphasized in the notes?\",\"answer\":\"The notes specify backfilling with clean sand within grading limits, providing bentonite around penetrations and seals, using geotextile materials with overlap, and using compression seals for pipe penetrations to ensure proper sealing.\"}]","Chapter III - Reference Drawings - Concrete and Romar Step and Gravity Septic Tank Installations - April 2024 | PDF",1792793681]