[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-650882-105":59,"doc-detail-650882-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","chapter-2-review-of-shop-drawings","Chapter 2 - Review of Shop Drawings","","Chapter 2 outlines the shop drawing review process used in Structure Construction (SC). It describes how the contract submission requirement should be discussed at preconstruction meetings, emphasizing complete submittals before the review period begins. It explains that, except for foundation pads and piles, falsework cannot start until shop drawings are authorized. It also details delegated responsibilities, the role of the Structure Representative, engineering analysis documentation, authorization and rejection, revision handling, review duration, and transmittals, including sample reports and letters.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/chapter-2-review-of-shop-drawings/650882/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/chapter-2-review-of-shop-drawings/650882.png","ImageObject",300,407,{"name":92,"@type":93},"404brain","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-24",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Who is responsible for reviewing and authorizing the Contractor’s shop drawings?","Question",{"text":112,"@type":113},"Review and authorization are delegated to the Structure Representative in responsible charge of structure work at the project site. The Structure Representative is expected to give personal attention during the review and provide concurrence before authorization.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"When can falsework construction begin relative to shop drawing authorization?",{"text":117,"@type":113},"With the exception of foundation pads and piles, falsework construction may not begin until the shop drawings are authorized.",{"name":119,"@type":110,"acceptedAnswer":120},"What happens to the engineering analysis findings from the shop drawing review?",{"text":121,"@type":113},"The findings from the engineering analysis are documented in an engineering analysis report.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},650882,1793066618,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},1099529839291,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","Chapter 2: Review of Shop Drawings Table of Contents  \nChapter 2: Review of Shop Drawings.............................................................................. 1  \nTable of Contents ........................................................................................................ 1  \n2-1 Introduction ..................................................................................................... 3  \n2-2 General Information ........................................................................................ 3  \n2-3 Design Calculations ........................................................................................ 4  \n2-4 Shop Drawing Review..................................................................................... 5  \n2-4.01 Initial Review ............................................................................................ 5  \n2-4.02 Review ..................................................................................................... 7  \n2-4.03 Engineering Analysis ................................................................................ 9  \n2-4.04 Sample Engineering Analysis Report ..................................................... 10  \n2-5 Review Duration............................................................................................ 13  \n2-6 Shop Drawing Authorization and Rejection ................................................... 13  \n2-6.01 Shop Drawing Authorization ................................................................... 13  \n2-6.02 Shop Drawing Rejection ......................................................................... 16  \n2-7 Cal/OSHA Requirements .............................................................................. 16  \n2-8 Revisions to Shop Drawings ......................................................................... 16  \n2-8.01 Revisions to Rejected Shop Drawings ................................................... 16  \n2-8.02 Revisions to Authorized Shop Drawings ................................................ 17  \n2-9 Chronological Record of Shop Drawing Review ........................................... 17  \n2-9.01 Introduction ............................................................................................ 17  \n2-9.02 Example of Chronological Record of Falsework Review ........................ 18  \n2-10 Transmittal to the Contractor ........................................................................ 20  \n2-10.01 Authorized Submittals ............................................................................ 20  \n2-10.02 Rejected Submittals ............................................................................... 21  \n2-10.03 Sample Transmittal Letters..................................................................... 21  \n2-11 Submittal Guidelines ..................................................................................... 25  \n2-11.01 Introduction ............................................................................................ 25  \n2-11.02 Submittals Where Railroad is Not Involved ............................................ 25  \n2-11.03 Submittals When Railroad is Involved .................................................... 25  \n2-11.04 File Naming Convention ......................................................................... 27  \n2-12 Responsibilities ............................................................................................. 28  \n2-12.01 Structure Representative ........................................................................ 28  \n2-12.02 Assistant Structure Representative ........................................................ 29  \n2-12.03 SC Falsework Engineer .......................................................................... 29  \n2-13 Field Review of Falsework ............................................................................ 29  \n2-13.01 Introduction ...........................................","cbCaifShVqtCXy1z","https://ap.wps.com/l/cbCaifShVqtCXy1z","pdf",682694,32,"English","# Chapter 2: Review of Shop Drawings\n## 2-1 Introduction\n## 2-2 General Information\n## 2-3 Design Calculations\n## 2-4 Shop Drawing Review\n## 2-4.01 Initial Review\n## 2-4.02 Review\n## 2-4.03 Engineering Analysis\n## 2-4.04 Sample Engineering Analysis Report\n## 2-5 Review Duration\n## 2-6 Shop Drawing Authorization and Rejection\n## 2-6.01 Shop Drawing Authorization\n## 2-6.02 Shop Drawing Rejection\n## 2-7 Cal/OSHA Requirements\n## 2-8 Revisions to Shop Drawings\n## 2-8.01 Revisions to Rejected Shop Drawings\n## 2-8.02 Revisions to Authorized Shop Drawings\n## 2-9 Chronological Record of Shop Drawing Review\n## 2-9.01 Introduction\n## 2-9.02 Example of Chronological Record of Falsework Review\n## 2-10 Transmittal to the Contractor\n## 2-10.01 Authorized Submittals\n## 2-10.02 Rejected Submittals\n## 2-10.03 Sample Transmittal Letters\n## 2-11 Submittal Guidelines\n## 2-11.01 Introduction\n## 2-11.02 Submittals Where Railroad is Not Involved\n## 2-11.03 Submittals When Railroad is Involved\n## 2-11.04 File Naming Convention\n## 2-12 Responsibilities\n## 2-12.01 Structure Representative\n## 2-12.02 Assistant Structure Representative\n## 2-12.03 SC Falsework Engineer\n## 2-13 Field Review of Falsework\n## 2-13.01 Introduction\n## 2-13.02 Structure Representative & Assistant Structure Representative\n## 2-13.03 Bridge Construction Engineer\n## 2-13.04 Area Construction Manager\n## 2-13.05 SC Oversight Engineer\n## 2-14 Review of Lighting Plan\n## 2-15 Review of Adjustment Plan","[{\"question\":\"Who is responsible for reviewing and authorizing the Contractor’s shop drawings?\",\"answer\":\"Review and authorization are delegated to the Structure Representative in responsible charge of structure work at the project site. The Structure Representative is expected to give personal attention during the review and provide concurrence before authorization.\"},{\"question\":\"When can falsework construction begin relative to shop drawing authorization?\",\"answer\":\"With the exception of foundation pads and piles, falsework construction may not begin until the shop drawings are authorized.\"},{\"question\":\"What happens to the engineering analysis findings from the shop drawing review?\",\"answer\":\"The findings from the engineering analysis are documented in an engineering analysis report.\"}]","Chapter 2 - Review of Shop Drawings | PDF",1792849669,81]