[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-460026-105":59,"doc-detail-460026-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","chapter-116-principles-and-methods-of-validation-of-diagnostic-assays-for-infectious-diseases","CHAPTER 1.1.6 - PRINCIPLES AND METHODS OF VALIDATION OF DIAGNOSTIC ASSAYS FOR INFECTIOUS DISEASES","","Adequate validation and verification of diagnostic tests for infectious diseases ensures assays are applied and interpreted in a scientifically robust, defensible manner. Validation determines whether an assay—properly developed, optimised, and standardised—fits its intended purpose, covering analytical and diagnostic performance for the relevant species and specimen. The chapter outlines how assays complete stages of the WOAH pathway, require ongoing monitoring in routine use, and may become unfit if results diverge from original data. It also explains key intended purposes and links development to validation, including guidance for different assay types, wildlife applications, and related standards.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/chapter-116-principles-and-methods-of-validation-of-diagnostic-assays-for-infectious-diseases/460026/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/chapter-116-principles-and-methods-of-validation-of-diagnostic-assays-for-infectious-diseases/460026.png","ImageObject",300,407,{"name":92,"@type":93},"Logic","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-06","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":34},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is validation in the context of diagnostic assays for infectious diseases?","Question",{"text":112,"@type":113},"Validation is a process that determines whether an assay, properly developed, optimised, and standardised, is fit for its intended purpose. It includes estimates of analytical and diagnostic performance for the species and specimen where it will be used.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Why is ongoing monitoring necessary after an assay is validated?",{"text":117,"@type":113},"Routine use can cause performance to drift. By tracking assay controls and reassessing performance over time in the targeted population, the assay can remain valid, or be identified as unfit if results no longer match the original validation data.",{"name":119,"@type":110,"acceptedAnswer":120},"How can a single diagnostic assay be validated for different intended purposes?",{"text":121,"@type":113},"By optimising performance characteristics for each purpose. For example, screening assays may be set with high diagnostic sensitivity but lower diagnostic specificity, while confirmatory assays may be set with high specificity but lower sensitivity.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},460026,1791483040,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":34,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":19,"preview_urls":146},1099513958762,"https://ap-avatar.wpscdn.com/avatar/1000023916a998db790?x-image-process=image/resize,m_fixed,w_180,h_180&k=1784791008015729253","C H A P T E R 1 . 1 . 6 .  \nPRINCIPLES AND METHODS OF VALIDATION OF DIAGNOSTIC ASSAYS FOR INFECTIOUS DISEASES  \nINTRODUCTION  \nAdequate validation and verification of the performance characteristics of diagnostic tests for infectious diseases are critical to ensuring that assays are applied and interpreted in a scientifically robust and defensible manner (Colling & Gardner, 2021). Since it was first adopted in 1996, the World Organisation for Animal Health (WOAH: founded as the OIE) Assay Development and Validation Pathway (Figure 1) has acted as the internationally recognised standard for the validation of veterinary diagnostic tests for infectious diseases.  \nValidation is a process that determines the fitness of an assay1, which has been properly developed, optimised and standardised, for an intended purpose. All diagnostic assays regardless of whether they are used in the laboratory or as point-of-care tests should be validated for the species and specimen in which they will be used. Validation includes estimates of the analytical and diagnostic performance characteristics ofa test. In the context of this chapter, an assay that has completed the first three stages of the validation pathway (see Figure 1 below), including performance characterisation, can be designated as “validated for the original intended purpose(s)”. To maintain a validated assay status, however, the assay’s performance should be carefully monitored under conditions of routine use, often by tracking the behaviour of assay controls within each run and through on-going assessment during routine diagnostic use in the targeted population over time. Should it no longer produce results consistent with the original validation data, the assay may be rendered unfit for its intended purpose(s).  \nAssays applied to individuals or populations have many purposes, such as aiding in: documenting freedom from disease in a country or region, preventing spread of disease through trade, contributing to eradication of an infection from a region or country, confirming diagnosis of clinical cases, estimating infection prevalence to facilitate risk analysis, identifying infected animals toward implementation of control measures, and classifying animals for herd health or immune status postvaccination. A single assay may be validated for one or more intended purposes by optimising its performance characteristics for each purpose, e.g. setting diagnostic sensitivity (DSe) high, with associated lower diagnostic specificity (DSp) for a screening assay, or conversely, setting DSp high with associated lower DSe for a confirmatory assay (see Section A.1 Definition of the intended purpose(s) of an assay).  \nThis chapter focuses on the criteria that must be fulfilled during assay development and validation of all assay types and the metrics used to characterise test performance. The inclusion of assay development as part of the assay validation process may seem counterintuitive, but in reality, three of the required validation criteria (definition of intended purpose[s], optimisation, and standardisation) that must be assessed in order to achieve a validated assay, comprise steps in the assay development process. Accordingly the assay development process seamlessly leads into anassay validation pathway, both of which require fulfilment of validation criteria. The guiding principles described herein also apply to infectious diseases that are not WOAH listed. More detailed guidance is provided in a series of recommendations for validation of diagnostic tests (Section 2.2 Validation of diagnostic tests, chapters 2.2.1 to 2.2.8) that are tailored for several fundamentally different types  \n1 “Assay,” “test method,” and “test” are synonymous terms for purposes of this chapter, and therefore are used interchangeably.  \nof assay (e.g. detection of antibodies, antigen and nucleic acids) and provide more information on specific issues related to the validation of diagnostic assays (Halpin et a","cbCaipNH5cO5syMu","https://ap.wps.com/l/cbCaipNH5cO5syMu","pdf",541131,27,"English","# Introduction\n## Purpose and scope of validation\n## Intended purposes of diagnostic assays\n## Assay development and validation pathway\n## Standards, reporting guidance, and proficiency testing","[{\"question\":\"What is validation in the context of diagnostic assays for infectious diseases?\",\"answer\":\"Validation is a process that determines whether an assay, properly developed, optimised, and standardised, is fit for its intended purpose. It includes estimates of analytical and diagnostic performance for the species and specimen where it will be used.\"},{\"question\":\"Why is ongoing monitoring necessary after an assay is validated?\",\"answer\":\"Routine use can cause performance to drift. By tracking assay controls and reassessing performance over time in the targeted population, the assay can remain valid, or be identified as unfit if results no longer match the original validation data.\"},{\"question\":\"How can a single diagnostic assay be validated for different intended purposes?\",\"answer\":\"By optimising performance characteristics for each purpose. For example, screening assays may be set with high diagnostic sensitivity but lower diagnostic specificity, while confirmatory assays may be set with high specificity but lower sensitivity.\"}]","CHAPTER 1.1.6 - PRINCIPLES AND METHODS OF VALIDATION OF DIAGNOSTIC ASSAYS FOR INFECTIOUS DISEASES | PDF",1790757538,68,[147,151,155,159],{"page_no":8,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/3ab808b6e307a00a4274d1532543e87b.webp",983,1390,{"page_no":14,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/4efd1c5820ccac643986efc214774888.webp",982,1388,{"page_no":81,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/17760faaefaf37c028be7e8ce34daf11.webp",981,1387,{"page_no":19,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/0668a2740993b8ddea27eeca7ad4d8ff.webp",980,1385]