[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-676886-105":59,"doc-detail-676886-en":129},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":122,"head_meta":124,"extra_data":126,"updated_unix":128},105,"en","cfam-wx-series-safety-precautions","CFAM-WX Series - Safety Precautions","","Instruction manual for BeaconMedaes CFAM-WX fully automatic switchover manifolds for liquid cylinders (scale weight actuated, for liquid withdrawal and liquid dispense). It addresses experienced operators using cryogens and compressed gases, stressing the need to read MSDS for each gas/fluid, restrict access to trained personnel, and follow safety labeling. Key guidance covers compatible gas/materials, ventilation and oxygen depletion warning, compliant venting and relief device installation, pressure limits, ignition prevention, slow valve opening, hose handling, secure cylinder storage, grounding for oxygen, and ammonia-free leak test solutions. Cryogen-specific sections define cryogenic liquids below −238°F (−150°C) and highlight cryogenic burns and thermal expansion hazards.",{"@graph":69,"@context":121},[70,84,104],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/cfam-wx-series-safety-precautions/676886/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":98,"encodingFormat":97,"isAccessibleForFree":99,"interactionStatistic":100},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/cfam-wx-series-safety-precautions/676886.png","ImageObject",300,407,{"name":92,"@type":93},"asda1da","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-04",true,{"@type":101,"interactionType":102,"userInteractionCount":8},"InteractionCounter",{"@type":103},"ViewAction",{"@type":105,"mainEntity":106},"FAQPage",[107,113,117],{"name":108,"@type":109,"acceptedAnswer":110},"Who should operate the CFAM-WX series manifolds, and what documents must be reviewed?","Question",{"text":111,"@type":112},"The instructions are for experienced operators who know cryogen and compressed gas safety precautions. Review the Material Safety Data Sheet (MSDS) for each fluid/gas being used.","Answer",{"name":114,"@type":109,"acceptedAnswer":115},"What ventilation and oxygen depletion precautions are required?",{"text":116,"@type":112},"Operate only in well-ventilated areas and vent gases away from personnel. Provide a device to warn personnel of oxygen depletion in the work area.",{"name":118,"@type":109,"acceptedAnswer":119},"What restrictions apply to leak test solutions and materials compatibility?",{"text":120,"@type":112},"Do not use leak test solutions containing ammonia, which can cause brass tubing to crack. Never use the manifolds with gases incompatible with the materials of construction.","https://schema.org",{"og:url":83,"og:type":123,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":125,"canonical":83},"index,follow",{"doc_id":127,"site_id":62},676886,1793776963,{"code":4,"msg":5,"data":130},{"doc_id":127,"user_id":131,"nickname":92,"user_avatar":132,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":8,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":138,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":128,"read_time":143},3985747861852,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","Instruction Manual  \nCFAM-WX Series  \nTHIS BOOKLET, WHICH CONTAINS PROPRIETARY INFORMATION OF BEACONMEDAES, IS PROVIDED TO THE PURCHASER SOLELY FOR USE IN CONJUNCTION WITH CFAM-WX SERIES FULLY AUTOMATIC SWITCHOVER MANIFOLDS FOR LIQUID CYLINDERS – SCALE (WEIGHT) ACTUATED (LIQUID WITHDRAW / LIQUID DISPENSE) .  \nImportant  \nThese instructions are for experienced operators who know the general principles and safety precautions to be observed in handling cryogens and compressed gases. If you are not certain you fully understand the safety precautions for handling cryogenic fluids and/or gases, we urge you to obtain and read the Material Safety Data Sheet (MSDS) for each fluid/gas being used.  \nDo not permit untrained persons to install, operate, or maintain these manifolds. Do not attempt to install or operate these equipment until you have read and fully understand these instructions. If you do not fully understand these instructions, contact BeaconMedaes.  \nBe sure this information reaches the operator. Your supplier has extra copies.  \nInstruction Manual  \nCFAM-WX Series  \n1- Safety Precautions - General  \nIn this page, unless noted otherwise, the word/term“gas(es)” applies to both compressed gas and cryogenic liquid.  \nProtect yourself and others. Read and understand the following instructions before attempting to use this equipment. Failure to understand and follow these instructions could result in serious personal injury and/or damage to equipment. Because of the many potential hazards associated with gases, read the Material Safety Data Sheet for each gas you will be using.  \n􀁸 Know and understand the physical and chemical properties of the gas being used.  \n􀁸 Observe general precautions for the use of gases.  \n􀁸 Observe safety precautions for the gas being used.  \n􀁸 Read and follow precautions on cylinder labels.  \n􀁸 Never use these manifolds with gases not compatible with the materials of construction. The use of gases not compatible with the materials of construction may cause damage to equipment or injury to personnel.  \n􀁸 Many gases can cause asphyxiation by displacing oxygen in the atmosphere. Make certain the area where these manifolds are operated is well ventilated. Provide a device to warn personnel of oxygen depletion in the work area.  \n􀁸 Use this equipment only in well ventilated areas. Vent gases to the outside atmosphere, and in an area away from personnel. Be sure that venting and disposal methods are in accordance with Federal, State, Provincial and local requirements. Locate and construct vent lines to prevent condensation or gas accumulation. Be sure the vent outlet is NOT obstructed by rain, snow, ice, insects, birds, etc. Do not inter-connect vent lines; if more than one vent is needed, use separate lines.  \n􀁸 Relief devices should be installed and properly vented in all gas handling systems to protect against equipment failure and overpressurization.  \n􀁸 Never connect this equipment to a supply source having a pressure greater than the maximum rated pressure. Refer to the Equipment Specifications for maximum inlet pressure.  \n􀁸 Never permit oil, grease, or other combustible materials to come in contact with cylinders, equipment, and connections. Oil and grease may react and ignite when in contact with some gases – particularly oxygen and nitrous oxide.  \n􀁸 Cylinder, header, and master valves should always be opened very s-l-o-w-l-y. Heat of recompression may ignite combustible materials.  \n􀁸 Flexible hoses should never be kinked, twisted, or bent into a radius smaller than 3 inches. Mistreatment may cause the flexible hoses to burst.  \n􀁸 Do not apply heat. Some materials may react and ignite while in contact with some gases – particularly oxygen and nitrous oxide.  \n􀁸 Cylinders should always be secured with racks, chains, or straps. Unrestrained cylinders may fall over and damage or break off the cylinder valve which may propel the cylinder with great force.  \n􀁸 Oxygen manifolds and cylinders should be","cbCaidqaZfEBnZ0Y","https://ap.wps.com/l/cbCaidqaZfEBnZ0Y","pdf",2208952,36,"English","# 1- Safety Precautions - General\n## GENERAL SAFETY PRECAUTIONS\n# 2- Safety Precautions - Cryogens\n## GENERAL SAFETY PRECAUTIONS","[{\"question\":\"Who should operate the CFAM-WX series manifolds, and what documents must be reviewed?\",\"answer\":\"The instructions are for experienced operators who know cryogen and compressed gas safety precautions. Review the Material Safety Data Sheet (MSDS) for each fluid/gas being used.\"},{\"question\":\"What ventilation and oxygen depletion precautions are required?\",\"answer\":\"Operate only in well-ventilated areas and vent gases away from personnel. Provide a device to warn personnel of oxygen depletion in the work area.\"},{\"question\":\"What restrictions apply to leak test solutions and materials compatibility?\",\"answer\":\"Do not use leak test solutions containing ammonia, which can cause brass tubing to crack. Never use the manifolds with gases incompatible with the materials of construction.\"}]","CFAM-WX Series - Safety Precautions | PDF",91]