[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-662499-105":59,"doc-detail-662499-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","century-house-ac-system-addition-notes-and-wall-penetration-details","CENTURY HOUSE AC SYSTEM ADDITION - NOTES AND WALL PENETRATION DETAILS","","Tender package drawings arranged by discipline for architectural, electrical, and mechanical scope, including a comprehensive list of abbreviations and general notes governing coordination, site verification, and reinstatement of finishes. Specifies work sequencing such as making good patches, re-installing affected devices like CCTV and lighting, completing tie-ins through a qualified contractor, and defining fire-stopping requirements for 1HR FRR wall openings. Includes wall penetration/stucco cladding detail sheets with scale callouts, plus definitions of make good and re & re.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/century-house-ac-system-addition-notes-and-wall-penetration-details/662499/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/century-house-ac-system-addition-notes-and-wall-penetration-details/662499.png","ImageObject",300,407,{"name":92,"@type":93},"Angel","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What does the document require contractors to do before construction starts?","Question",{"text":112,"@type":113},"Verify site conditions and dimensions prior to start of construction and report any variations affecting scope or setting out to obtain direction from the consultants.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How should affected existing finishes be restored after new work?",{"text":117,"@type":113},"Patch and make good all existing finish where affected, including refinishing entire wall/ceiling surfaces to match existing finish and colour, so no visible traces remain at specified viewing distance.",{"name":119,"@type":110,"acceptedAnswer":120},"What requirement applies to 1HR FRR wall openings?",{"text":121,"@type":113},"Openings must be boxed in with 5/8\" Type X GWB, and provide fire stopping at penetrations.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},662499,1793218524,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144},687207412472,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","TENDER PACKAGE DRAWINGS IN ORDER OF ARRANGEMENT: ARCHITECTURAL DRAWINGS (9 PAGES)  \nELECTRICAL DRAWINGS (6 PAGES)  \nMECHANICAL DRAWINGS (15 PAGES)  \n| \u003Cbr>LIST OF ABBREVIATIONS ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION ARCH ARCHITECTURAL FIN FINISH OR FINISHED PREFIN PREFINISHED ALT ALTERNATE FIN FLR FINISHED FLOOR PT PRESSURE TREATED ALUM ALUMINUM GALV GALVANIZED PNT PAINT ANOD ANODIZED GWB GYPSUM WALLBOARD PNTD PAINTED BLDG BUILDING HC HANDICAPPED REINF REINFORCED, REINFORCEMENT BLK BLOCK HORIZ HORIZONTAL REQ'D REQUIRED BLKG BLOCKING INSUL INSULATION RO ROUGH OPENING BP BUILDING PAPER INT INTERIOR SEAL SEALANT CAULK CAULKING LA LIQUID APPLIED SHEATH SHEATHING CONC CONCRETE MAX MAXIMUM SIM SIMILAR CONT CONTINUOUS MECH MECHANICAL SPEC SPECIFICATION COORD COORDINATE (WITH) MEMB MEMBRANE STRUCT STRUCTURAL COL COLUMN MIN MINIMUM THK THICK C/W COMPLETE WITH MTL METAL TYP TYPICAL DBL DOUBLE NTS NOT TO SCALE U/G UNDERGROUND DTL DETAIL OC ON CENTRE UNO UNLESS NOTED OTHERWISE DWG DRAWING O/H OVERHEAD U/S UNDERSIDE EA EACH P&S PEEL & STICK VB VAPOUR BARRIER ELEV DRAWING ELEVATION PERIM PERIMETER VR VAPOUR RETARDER ELEC ELECTRICAL PLAM PLASTIC LAMINATE VERT VERTICAL EXIST EXISTING PLY PLYWOOD WDW WINDOW EXT EXTERIOR POLY POLY VAPOUR BARRIER WP WATERPROOF(ING) NOTE: THIS IS NOT AN EXHAUSTIVE LIST. IF IN DOUBT, CONTACT THE CONSULTANT FOR CLARIFICATION\u003Cbr>General Notes 1. This drawing is prepared from archival information and from limited site review. Actual conditions may vary. The contractor shall verify site conditions and dimensions prior to start of construction. The contractor shall report any variations that affect the scope or setting out of the work and obtain direction from the consultants. 2. Patch and Make good all existing finish where affected by new work. 3. Drawings to be read in conjunction with mechanical, electrical and structural drawings. 4. Remove and reinstall existing CCTV camera, lighting equipments and fire exit signs needed to complete work. 5. Where an existing surface material is re-instated to match the existing material, refinish the entire wall and/ or ceiling surfaces to match existing finish and colour. 6. All roofing, patching, penetrations and tie-ins are to be completed by a RCABC approved contractor.\u003Cbr>NOTE:\u003Cbr>FOR 1HR FRR WALLS\u003Cbr>OPENING MUST BE BOXED IN WITH 5/8\" TYPE X GWB. PROVIDE FIRE STOPPING AT PENETRATIONS\u003Cbr>\u003Cbr>\u003Cbr>3 A100\u003Cbr>TYP. WALL PENETRATION-STUCCO CLADDING\u003Cbr>SCALE: N.T.S.\u003Cbr>\u003Cbr>A100 SCALE: 3/32\" = 1'-0\" A100 SCALE: 3/32\" = 1'-0\"\u003Cbr>REMOVE+ REINSTALL SUFFICIENT BRICK CLADDING TO ALLOW FOR CLOSURES . PATCH/ REPAIR\u003Cbr>TO MATCH EXISTING\u003Cbr>REMOVE SUFF IC IENT DRY WALL\u003Cbr>TO ALLOW FOR INSTALLATION OF\u003Cbr>BLOCK ING AND CLOSURES .\u003Cbr>PATCH/ REPAIR TO MATCH EXISTING\u003Cbr>EX IST WALL ASSEMBLY\u003Cbr>REMOVE SUFFICIENT STUCCO TO ALLOW FOR CLOSURES .\u003Cbr>PATCH AND REPAIR TO MATCH EXISTING\u003Cbr>1\"\u003Cbr>REMOVE SUFF IC IENT DRY WALL TO ALLOW FOR INSTALLATION OF BLOCK ING AND CLOSURES . PATCH AND REPAIR TO MATCH ADJACENT EXISTING AS NEEDED\u003Cbr>Definitions:\u003Cbr>1.\"making good\" and/or \"make good\" shall be defined as preparing new surfaces which are identical to adjacent surfaces (with similar backing materials), and finished off in such a manner that there are absolutely no visible traces (at a distance of 600mm / 2 feet) between existing work and the work of new patching. \"making good\" therefore, extends to the complete re-finishing of entire surface areas as is necessary, to junction points or inside or outside corners of walls, partitions and ceilings.\u003Cbr>2. \"making good\" for painting refers to satisfactorily preparing finish surfaces for paint, so that newly patched surfaces are indistinguishable from immediately adjacent existing finishes of similar materials.\u003Cbr>3. \"patch and paint\" for painting shall mean \"make good\".\u003Cbr>4. \"re & re\" shall mean, remove, safely store and reinstall in a proper functional condition. Make good areas affected by this work. | |  |  |  |  |  |  |\n|","cbCaie8V5y5MO4of","https://ap.wps.com/l/cbCaie8V5y5MO4of","pdf",7932307,31,"English","# General Notes\n## Definitions\n## Wall Penetration Detail (A100)","[{\"question\":\"What does the document require contractors to do before construction starts?\",\"answer\":\"Verify site conditions and dimensions prior to start of construction and report any variations affecting scope or setting out to obtain direction from the consultants.\"},{\"question\":\"How should affected existing finishes be restored after new work?\",\"answer\":\"Patch and make good all existing finish where affected, including refinishing entire wall/ceiling surfaces to match existing finish and colour, so no visible traces remain at specified viewing distance.\"},{\"question\":\"What requirement applies to 1HR FRR wall openings?\",\"answer\":\"Openings must be boxed in with 5/8\\\" Type X GWB, and provide fire stopping at penetrations.\"}]","CENTURY HOUSE AC SYSTEM ADDITION - NOTES AND WALL PENETRATION DETAILS | PDF",78]