[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-501715-105":59,"doc-detail-501715-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","ccat-the-410-ghz-camera-module-for-fyst-design-and-testing-of-the-mkid-focal-plane","CCAT: The 410 GHz camera module for FYST - design and testing of the MKID focal plane","","Prime-Cam, the primary first-light instrument for the Fred Young Submillimeter Telescope (FYST) by the CCAT Collaboration, will host seven modules, including an off-central 410 GHz imager/polarimeter. The paper presents the 410 GHz camera module development, optical coupling approach, and evaluation of four MKID test devices with different inductor volumes to optimize performance. It proposes a ~6,700-horn-coupled TiN MKID array and assesses optical properties (Qi/Qc, responsivity) within the 410 GHz atmospheric window, including frequency-designed readout using a two-octave RFSoC system.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/ccat-the-410-ghz-camera-module-for-fyst-design-and-testing-of-the-mkid-focal-plane/501715/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/ccat-the-410-ghz-camera-module-for-fyst-design-and-testing-of-the-mkid-focal-plane/501715.png","ImageObject",300,407,{"name":92,"@type":93},"dabgoudw","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-11","2026-10-03",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",12,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What is the 410 GHz instrument module described in the document?","Question",{"text":113,"@type":114},"It is an off-central 410 GHz imager/polarimeter module for Prime-Cam on FYST, designed as a CCAT collaboration effort for camera operation in the 410 GHz atmospheric window.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How are the MKID detectors assessed for 410 GHz performance?",{"text":118,"@type":114},"Four MKID test devices with varying inductor volumes are optically tested to determine optimal Qi/Qc and responsivity for operation at 410 GHz.",{"name":120,"@type":111,"acceptedAnswer":121},"What readout approach is planned for the 410 GHz MKIDs?",{"text":122,"@type":114},"Detectors are designed for efficient multi-octave readout using a second-generation two-octave system based on a Xilinx RFSoC board, targeting over 4000 detectors per board.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},501715,1791029247,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":146,"preview_page_count":19,"preview_urls":147},3985747860484,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","arXiv :2608 .04282v1 [ astro-ph .IM] 4 Aug 2026  \nCCAT: The 410 GHz camera module for FYST – design and  \ntesting of the MKID focal plane.  \nScott C. Chapmana,b,c , Jordan Wheelerd , Anthony Huberb , Jason Austermannd , James A.  \nBealld , James Burgoyneb,c , Max Chapmane , Jesslyn Devinab , Douglas Henkef, Johannes Hubmayrd , Dylan Lockyere , Michael Niemackg , Tilak M. Patelh , Colin Rossa , Douglas Scottb , Adrian Sinclairi , Eve Vavagiakish , Michael R. Vissersd , and Ruixuan (Matt) Xieb  \naDept. of Physics and Atmospheric Science, Dalhousie University, Halifax, BC, Canada b Dept. of Physics and Astronomy, University of British Columbia, Vancouver, BC, Canada c Dept. of Physics and Astronomy, University of Victoria, Victoria, BC, Canada  \nd Quantum Sensors Group, National Institute of Standards and Technology, Boulder, CO,  \nUnited States  \ne Department of Engineering, McGill University, Montreal, QC, Canada fNRC Herzberg Astronomy & Astrophysics Research Centre, Victoria, BC, Canada g Department of Physics, Cornell University, Ithaca, NY 14853, USA h Department of Physics, Duke University, Durham, NC 27710, USA  \niWilliam H. Miller III Department of Physics and Astronomy, Johns Hopkins University,  \nBaltimore, MD, USA  \nABSTRACT  \nPrime-Cam, the primary first-light instrument for the Fred Young Submillimeter Telescope (FYST) developed by the Cerro Chajnantor Atacama Telescope (CCAT) Collaboration, will accommodate seven modules. Here we describe the off-central 410 GHz imager/polarimeter. The 410 GHz instrument is a camera module for CCAT funded by the Canadian Foundation for Innovation, being developed as a collaboration between Dalhousie University, University of British Columbia (UBC), National Research Council (NRC) -Herzberg, and Duke University. With atmospheric loading in the 410 GHz window being significantly higher than at 350 GHz (but substantially lower than 850 GHz), we assess four MKID test devices with varying inductor volume for performance at 410 GHz. We propose a design for an array of ∼6,700 horn-coupled TiN MKIDs optimized for use at 410 GHz, with a planned ∼20,000 MKIDs over three arrays, exploring mapping speed versus detector number. We test the four MKID devices optically and assess optimal Qi /Qc and responsivity for the 410 GHz atmospheric window atop Cerro Chajnantor. The detectors will be designed in frequency to be efficiently readout with a second generation, two octave readout (based on the Xilinx RFSoC board), with over 4000 detectors per board.  \n1. INTRODUCTION  \nThe Fred Young Submillimeter Telescope (FYST) at the Cerro Chajnantor Atacama Telescope (CCAT) observatory is a 6-m aperture submillimeter (sub-mm) to millimeter (mm) wave telescope, situated near the Cerro Chajnantor summit high in the Atacama Desert in Chile, and completed in April 2026 . FYST is sited 5600 meters above sea level, providing a high, dry site suitable to negate much of the atmospheric effects, such as absorption by atmospheric water vapor, which plague terrestrial infrared observations.1 FYST’s extremely wide field of view (FoV) crossed-Dragone design will enable far faster mapping than existing facilities (Figure 1: 2 ) The off-axis 6-m telescope design2 achieves very low, \u003C1%, emissivity to take advantage of the Cerro Chajnantor site for sub-mm/mm wave astrophysics. The high surface accuracy, half-wavefront error of ∼ 10.7µm, ensures excellent sub-mm sensitivity, crucial for observations at the highest frequencies.  \nFurther author information: Send correspondence to S.C.C.: E-mail: [scott.chapman@dal.ca](scott.chapman@dal.ca)  \nFigure 1 . Left: Atmospheric transmission at the CCAT site, Cerro Chajnantor, identifying the exquisite 410 GHz transparency compared to the ALMA and Mauna Kea sites. Right Top: a photo of the site, and Right Bottom: the improvement in sub-mm mapping speed expected at 5600 m relative to that of the ALMA Plateau, highlighting 410 GHz  \nPrime-Cam, the primary first generation instrument on","cbCaillROCkjkUdo","https://ap.wps.com/l/cbCaillROCkjkUdo","pdf",8007222,13,"English","# Abstract\n# 1. Introduction","[{\"question\":\"What is the 410 GHz instrument module described in the document?\",\"answer\":\"It is an off-central 410 GHz imager/polarimeter module for Prime-Cam on FYST, designed as a CCAT collaboration effort for camera operation in the 410 GHz atmospheric window.\"},{\"question\":\"How are the MKID detectors assessed for 410 GHz performance?\",\"answer\":\"Four MKID test devices with varying inductor volumes are optically tested to determine optimal Qi/Qc and responsivity for operation at 410 GHz.\"},{\"question\":\"What readout approach is planned for the 410 GHz MKIDs?\",\"answer\":\"Detectors are designed for efficient multi-octave readout using a second-generation two-octave system based on a Xilinx RFSoC board, targeting over 4000 detectors per board.\"}]","CCAT: The 410 GHz camera module for FYST - design and testing of the MKID focal plane | PDF",1791023474,33,[148,152,156,160],{"page_no":8,"url":149,"width":150,"height":151},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/237cb47df52bfa2416c2823b285eb472.webp",983,1272,{"page_no":14,"url":153,"width":154,"height":155},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/875f11d83cebfd15e5e258ad3c54f7b5.webp",982,1270,{"page_no":81,"url":157,"width":158,"height":159},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/44653568efd2b2160c61af86d4d8d7c5.webp",981,1269,{"page_no":19,"url":161,"width":162,"height":163},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/58fce12abbe07460d3b44c12117d728f.webp",980,1268]