[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-501562-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-501562-en":131},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","ccat-prime-design-of-the-mod-cam-receiver-and-280-ghz-mkid-instrument-module","CCAT-prime - Design of the Mod-Cam receiver and 280 GHz MKID instrument module","","Mod-Cam is a first-light commissioning instrument for the CCAT-prime project's six-meter aperture Fred Young Submillimeter Telescope (FYST), currently under construction on Cerro Chajnantor in Chile. Prime-Cam will provide over ten times higher mapping speed than current and near-term facilities for unprecedented 280–850 GHz broadband and spectroscopic measurements using microwave kinetic inductance detectors (MKIDs). Planned for early observations in 2024, Mod-Cam validates instrument modules for Prime-Cam, including the 0.9 m receiver and 280 GHz module cryogenic readout enabling over 10,000 MKID readout across 18 networks.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/ccat-prime-design-of-the-mod-cam-receiver-and-280-ghz-mkid-instrument-module/501562/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/ccat-prime-design-of-the-mod-cam-receiver-and-280-ghz-mkid-instrument-module/501562.png","ImageObject",300,407,{"name":42,"@type":43},"Marglet","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-18","2026-10-03",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",13,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What is Mod-Cam in the CCAT-prime project?","Question",{"text":63,"@type":64},"Mod-Cam is a first-light and commissioning instrument for FYST, serving to test and validate instrument modules that will be used in Prime-Cam.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"What frequency range does CCAT-prime instrumentation target?",{"text":68,"@type":64},"Prime-Cam enables broadband and spectroscopic measurements across roughly 280–850 GHz, supporting additional mapping and line-intensity work in related sub-bands.",{"name":70,"@type":61,"acceptedAnswer":71},"How is the Mod-Cam receiver and 280 GHz instrument module cryogenically structured?",{"text":72,"@type":64},"The 0.9 m receiver and 280 GHz instrument module include multiple cold stages at 40 K, 4 K, 1 K, and 100 mK, together with cryogenic readout designs for large MKID counts.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},501562,1791025882,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,115,120,123,127],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":112,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":113,"slug":114},8,30,"research-report",{"id":116,"doc_module":4,"doc_module_name":25,"category_name":117,"show_sort_weight":118,"slug":119},9,"Religion & Spirituality",20,"religion-spirituality",{"id":118,"doc_module":4,"doc_module_name":25,"category_name":121,"show_sort_weight":118,"slug":122},"World Cup","world-cup",{"id":124,"doc_module":4,"doc_module_name":25,"category_name":125,"show_sort_weight":124,"slug":126},10,"Lifestyle","lifestyle",{"id":128,"doc_module":4,"doc_module_name":25,"category_name":129,"show_sort_weight":97,"slug":130},19,"General","general",{"code":4,"msg":82,"data":132},{"doc_id":79,"user_id":133,"nickname":42,"user_avatar":134,"doc_module":4,"category_id":112,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":140,"language":141,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":12,"update_tm":145,"read_time":109,"preview_page_count":33,"preview_urls":146},2336477982702,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","arXiv :2208 .05468v1 [ astro-ph .IM] 10 Aug 2022  \nCCAT-prime: Design of the Mod-Cam receiver and 280 GHz  \nMKID instrument module  \nEve M. Vavagiakisa , Cody J. Duella , Jason Austermannb , James Beallb , Tanay Bhandarkarc , Scott C. Chapmand , Steve K. Choia,g , Gabriele Coppie,f, Simon Dickerc , Mark Devlinc , Rodrigo G. Freundtg , Jiansong Gaob , Christopher Groppih , Terry L. Herterg , Zachary B. Hubera ,  \nJohannes Hubmayrb , Doug Johnstonei,j , Ben Kellera , Anna M. Kofmanc , Yaqiong Lia,k , Philip Mauskopfh , Je􀀋 McMahonl , Jenna Mooreh , Colin C. Murphya , Michael D. Niemacka,g , Thomas Nikolam , John Orlowski-Schererc , Kayla M. Rossim , Adrian K. Sinclairn , Gordon J. Staceyg ,  \nJoel Ullomb , Michael Vissersb , Jordan Wheelerb , Zhilei Xuo , Ningfeng Zhuc , and Bugao Zoup  \na Department of Physics, Cornell University, Ithaca, NY, 14853, USA b Quantum Sensors Group, NIST, Boulder, CO, 80305, USAc Department of Physics and Astronomy, University of Pennsylvania, Philadelphia, PA 19104,  \nUSA  \nd Department of Physics and Atmospheric Science, Dalhousie University, Halifax, NS, B3H  \n4R2, Canada  \ne Department of Physics, University of Milano-Bicocca, Piazza della Scienza 3, 20126 Milano,  \nItaly  \nfNational Institute for Nuclear Physics (INFN), Sezione di Milano-Bicocca, Piazza della  \nScienza 3, 20126 Milano, Italy  \ng Department of Astronomy, Cornell University, Ithaca, NY, 14853, USA h School of Earth and Space Exploration, Arizona State University, Tempe, AZ, 85281, USA i National Research Council, Herzberg Astronomy and Astrophysics, Victoria, BC, V9E  \n2E7,Canada  \nj Department of Physics and Astronomy, University of Victoria, Victoria, BC, V8P 5C2,  \nCanada  \nkKavli Institute at Cornell for Nanoscale Science, Cornell University, Ithaca, NY, 14853, USAl Department of Astronomy and Astrophysics, University of Chicago, Chicago, IL, 60637, USAm Cornell Center for Astrophysics and Planetary Sciences, Cornell University, Ithaca, NY,  \n14853, USA  \nn Department of Physics and Astronomy, University of British Columbia, Vancouver, BC, V6T  \n1Z1, Canada  \noMIT Kavli Institute, Massachusetts Institute of Technology, 77 Massachusetts Avenue,  \nCambridge, MA 02139, USA  \np Department of Applied and Engineering Physics, Cornell University, Ithaca, NY 14853, USA  \nABSTRACT  \nMod-Cam is a 􀀌rst light and commissioning instrument for the CCAT-prime project's six-meter aperture Fred Young Submillimeter Telescope (FYST), currently under construction at 5600 m on Cerro Chajnantor in Chile's Atacama Desert. Prime-Cam, a 􀀌rst-generation science instrument for FYST, will deliver over ten times greater mapping speed than current and near-term facilities for unprecedented 280{850 GHz broadband and spectroscopic  \nFurther author information: (Send correspondence to E.M.V.)  \nE.M.V.: E-mail: [ev66@cornell.edu](ev66@cornell.edu), Telephone: 1 607 255 0474  \nmeasurements with microwave kinetic inductance detectors (MKIDs) . CCAT-prime will address a suite of science goals, from Big Bang cosmology to star formation and galaxy evolution over cosmic time. Mod-Cam deployment on FYST with a 280 GHz instrument module containing MKID arrays is planned for early science observations in 2024. Mod-Cam will be used to test instrument modules for Prime-Cam, which can house up to seven instrument modules. We discuss the design and status of the 0.9 m diameter, 1.8 m long Mod-Cam receiver and 40 cm diameter 280 GHz instrument module, with cold stages at 40 K, 4 K, 1 K, and 100 mK. We also describe the instrument module's cryogenic readout designs to enable the readout of more than 10,000 MKIDs across 18 networks.  \nKeywords: Cryogenics, Superconducting detectors, Readout, Instrumentation, Cosmic Microwave Background, Kinetic Inductance Detectors, Submillimeter Astronomy  \n1. INTRODUCTION  \nThe Fred Young Submillimeter Telescope (FYST) will be a 6-meter aperture crossed-Dragone telescope for the CCAT-prime Observatory at 5600 m elevation on Cerro Chajnanto","cbCaillXTXzEj3A2","https://ap.wps.com/l/cbCaillXTXzEj3A2","pdf",18908697,16,"English","# Introduction\n## CCAT-prime, FYST, and Prime-Cam overview\n## Prime-Cam instrumentation and MKID deployment\n## Mod-Cam scope and receiver design\n# Instrument module design\n## Cryogenic stages and thermal architecture\n## Cryogenic readout for MKIDs","[{\"question\":\"What is Mod-Cam in the CCAT-prime project?\",\"answer\":\"Mod-Cam is a first-light and commissioning instrument for FYST, serving to test and validate instrument modules that will be used in Prime-Cam.\"},{\"question\":\"What frequency range does CCAT-prime instrumentation target?\",\"answer\":\"Prime-Cam enables broadband and spectroscopic measurements across roughly 280–850 GHz, supporting additional mapping and line-intensity work in related sub-bands.\"},{\"question\":\"How is the Mod-Cam receiver and 280 GHz instrument module cryogenically structured?\",\"answer\":\"The 0.9 m receiver and 280 GHz instrument module include multiple cold stages at 40 K, 4 K, 1 K, and 100 mK, together with cryogenic readout designs for large MKID counts.\"}]","CCAT-prime - Design of the Mod-Cam receiver and 280 GHz MKID instrument module | PDF",1791020592,[147,151,155,159],{"page_no":22,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/8b4425469e500253109c581b4f68515a.webp",983,1272,{"page_no":26,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/62c75095c3805208f1a024458d6a6445.webp",982,1270,{"page_no":30,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/4d13fe92dca370814e3224a5989db1e3.webp",981,1269,{"page_no":33,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/70e39c70dcb93422a05f30a1cb274dce.webp",980,1268]