[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-502059-105":59,"doc-detail-502059-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","ccat-a-status-update-on-the-eor-spec-instrument-module-for-prime-cam","CCAT - A status update on the EoR-Spec instrument module - for Prime-Cam","","The Epoch of Reionization Spectrometer (EoR-Spec) is an upcoming Line Intensity Mapping (LIM) instrument aimed at studying the early universe’s evolution (z = 3.5 to 8) via the redshifted [CII] 158 µm fine-structure line from galaxy aggregates. [CII] serves as a strong tracer of star formation, enabling investigation of reionization driven by early stellar activity. EoR-Spec will operate on Prime-Cam, using >6500 MKIDs and a cryogenic scanning Fabry-Perot Interferometer for R ~ 100, with planned tomographic surveys and first light in 2026.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/ccat-a-status-update-on-the-eor-spec-instrument-module-for-prime-cam/502059/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/ccat-a-status-update-on-the-eor-spec-instrument-module-for-prime-cam/502059.png","ImageObject",300,407,{"name":92,"@type":93},"Maya Linwood","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-11","2026-10-03",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",11,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What scientific period and target line does EoR-Spec study?","Question",{"text":113,"@type":114},"EoR-Spec targets the epoch of reionization, studying z = 3.5 to 8, using the redshifted [CII] 158 µm fine-structure line.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"Why is the [CII] line important for reionization research?",{"text":118,"@type":114},"The [CII] emission is a dominant cooling line from neutral gas heated by OB star light, making it an excellent tracer of star formation and thus of reionization.",{"name":120,"@type":111,"acceptedAnswer":121},"What are key instrument design elements of EoR-Spec on Prime-Cam?",{"text":122,"@type":114},"Prime-Cam uses a >6500 MKID image plane illuminated by a 4-lens optical design and a cryogenic scanning Fabry-Perot Interferometer at the pupil, providing resolving power R ~ 100 over 210–420 GHz.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},502059,1791034792,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":52,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":19,"preview_urls":146},962084928432,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","CCAT: A status update on the EoR-Spec instrument module  \nfor Prime-Cam  \nRodrigo Freundt a , Yaqiong Lib , Doug Henkec , Jason Austermannd , James R. Burgoynee , Scott Chapmanc,e,f, Steve K. Choi g , Cody J. Duellb , Zach Huberb , Michael Niemackb,a , Thomas Nikolah , Lawrence Linb , Dominik A. Riechersi , Gordon Staceya , Anna K. Vaskurid , Eve M. Vavagiakisb,j , Jordan Wheelerd , Bugao Zouk , and the CCAT collaboration 1  \na Department of Astronomy, Cornell University, Ithaca, NY 14853, USA. b Department of Physics, Cornell University, Ithaca, NY 14853, USA.  \ncNRC Herzberg Astronomy and Astrophysics, 5071 West Saanich Rd, Victoria, BC, V9E 2E7,  \nCanada.  \nd Quantum Sensors Division, National Institute of Standards and Technology, Boulder, CO  \n80305, USA.  \ne Department of Physics and Astronomy, University of British Columbia, Vancouver, V6T 1Z1,  \nCanada.  \nfDepartment of Physics and Atmospheric Science, Dalhousie University, Halifax, NS, B3H 4R2,  \nCanada.  \ng Department of Physics and Astronomy, University of California, Riverside, CA 92521, USA h Cornell Center for Astrophysics and Planetary Sciences, Cornell University, Ithaca, NY  \n14853, USA.  \niInstitut f¨ur Astrophysik, Universit¨at zu K¨oln, Z¨ulpicher Strasse 77, 50937 K¨oln, Germany.  \nj Department of Physics, Duke University, Durham, NC 27708, USA. k Department of Applied and Engineering Physics, Cornell University, Ithaca, NY 14853, USA.  \nABSTRACT  \nThe Epoch of Reionization Spectrometer (EoR-Spec) is an upcoming Line Intensity Mapping (LIM) instrument designed to study the evolution of the early universe (z = 3.5 to 8) by probing the redshifted [CII] 158 µm finestructure line from aggregates of galaxies. The [CII] emission is an excellent tracer of star formation since it is the dominant cooling line from neutral gas heated by OB star light and thus can be used to probe the reionization of the early Universe due to star formation. EoR-Spec will be deployed on Prime-Cam, a modular direct-detection receiver for the 6-meter Fred Young Submillimeter Telescope (FYST), currently under construction by CPI Vertex Antennentechnik GmbH and to be installed near the summit of Cerro Chajnantor in the Atacama Desert. This instrument features an image plane populated with more than 6500 Microwave Kinetic Inductance Detectors (MKIDs) that are illuminated by a 4-lens optical design with a cryogenic, scanning Fabry-Perot Interferometer (FPI) at the pupil of the optical system. The FPI is designed to provide a spectral resolving power of R ∼ 100 over the full spectral range of 210–420 GHz. EoR-Spec will tomographically survey the E-COSMOS and ECDFS fields with a depth of about 4000 hours over a 5 year period. Here we give an update on EoR-Spec’s final mechanical/optical design and the current status of fabrication, characterization and testing towards first light in 2026 .  \nKeywords: Epoch of Reionization, Line Intensity Mapping, CII, Fabry-Perot Interferometer, MKIDs  \nFurther author information: (Send correspondence to R.F.)  \nR.F.: E-mail: [rgf57@cornell.edu](rgf57@cornell.edu)  \nMillimeter, Submillimeter, and Far-Infrared Detectors and Instrumentation for Astronomy XII, edited by Jonas Zmuidzinas, Jian-Rong Gao, Proc. of SPIE Vol. 13102, 131020U · © 2024 SPIE · 0277-786X · doi: 10. 1117/12 .3018477  \nProc. of SPIE Vol. 13102 131020U-1  \n1. INTRODUCTION  \nAn important outcome of the formation of the first stars and galaxies in the early universe is the so-called Epoch of Reionization (EoR), a cosmic time that has been technically difficult to probe due to the intrinsically faint, redshifted emission from these first luminous objects. During the EoR, the primordial hydrogen left after recombination (z ∼ 1100) underwent a gradual changeover from neutral to fully ionized as the strong radiation fields produced by these first stars and galaxies heated the interstellar and intergalactic mediums. There is solid observational evidence from the absorption spectra of distant quas","cbCaipuHFLfDD0ce","https://ap.wps.com/l/cbCaipuHFLfDD0ce","pdf",5064300,"English","# Abstract\n# Introduction","[{\"question\":\"What scientific period and target line does EoR-Spec study?\",\"answer\":\"EoR-Spec targets the epoch of reionization, studying z = 3.5 to 8, using the redshifted [CII] 158 µm fine-structure line.\"},{\"question\":\"Why is the [CII] line important for reionization research?\",\"answer\":\"The [CII] emission is a dominant cooling line from neutral gas heated by OB star light, making it an excellent tracer of star formation and thus of reionization.\"},{\"question\":\"What are key instrument design elements of EoR-Spec on Prime-Cam?\",\"answer\":\"Prime-Cam uses a \\u003e6500 MKID image plane illuminated by a 4-lens optical design and a cryogenic scanning Fabry-Perot Interferometer at the pupil, providing resolving power R ~ 100 over 210–420 GHz.\"}]","CCAT - A status update on the EoR-Spec instrument module - for Prime-Cam | PDF",1791028034,25,[147,151,155,159],{"page_no":8,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/4c029faaa63df12b9f49534cebbc3ead.webp",983,1272,{"page_no":14,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/58fc4ee19094420a146a0930a258a441.webp",982,1270,{"page_no":81,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/81d5e205977e1c1e46af3e9f10d9d2e0.webp",981,1269,{"page_no":19,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/aaa6d2322a3ea20244353d766c5833c7.webp",980,1268]