[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-663560-105":59,"doc-detail-663560-en":129},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":122,"head_meta":124,"extra_data":126,"updated_unix":128},105,"en","cbi-composite-elevated-tank-drawings","CBI-Composite-Elevated-Tank-Drawings","","This technical document provides detailed engineering schematics and architectural drawings for a composite elevated water storage tank. It outlines essential structural components including the concrete support structure, internal access ladders, inlet and outlet piping systems, and roof hatch configurations. The content includes general notes regarding foundation requirements, safety compliance with OSHA standards, and specifications for optional accessories. It serves as a comprehensive reference for site orientation, electrical entrance planning, and overall tank assembly, ensuring that the installation of water storage infrastructure meets specified load and durability requirements for water management projects.",{"@graph":69,"@context":121},[70,84,104],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":57,"@type":76,"position":81},"https://docshare.wps.com/document/general/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/cbi-composite-elevated-tank-drawings/663560/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":98,"encodingFormat":97,"isAccessibleForFree":99,"interactionStatistic":100},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/cbi-composite-elevated-tank-drawings/663560.png","ImageObject",300,407,{"name":92,"@type":93},"Mimi","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-28",true,{"@type":101,"interactionType":102,"userInteractionCount":4},"InteractionCounter",{"@type":103},"ViewAction",{"@type":105,"mainEntity":106},"FAQPage",[107,113,117],{"name":108,"@type":109,"acceptedAnswer":110},"What are the primary factors determining the foundation dimensions for the elevated tank?","Question",{"text":111,"@type":112},"The concrete support structure diameter and foundation dimensions are determined by the tank contractor, based on the specified soil bearing capacity and recommendations from the project's soil report.","Answer",{"name":114,"@type":109,"acceptedAnswer":115},"What safety standards must the ladder systems comply with?",{"text":116,"@type":112},"All galvanized ladder safety devices must meet OSHA standards when required for installation.",{"name":118,"@type":109,"acceptedAnswer":119},"What is the purpose of the internal ladders within the concrete support structure?",{"text":120,"@type":112},"Internal ladders provide access to the various levels of the tank and roof; however, the drawings note that inside tank ladders are not recommended for cold climates.","https://schema.org",{"og:url":83,"og:type":123,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":125,"canonical":83},"index,follow",{"doc_id":127,"site_id":62},663560,1793229294,{"code":4,"msg":5,"data":130},{"doc_id":127,"user_id":131,"nickname":92,"user_avatar":132,"doc_module":4,"category_id":56,"category_name":57,"doc_title":65,"doc_description":67,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":4,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":81,"language":138,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":139,"faqs":140,"seo_title":141,"seo_description":67,"update_tm":128,"read_time":24},2336477974920,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","| MCDERMOTT   |  | SBAS   |  |\n| --- | --- | --- | --- |\n| ELEVATION  \u003Cbr>ELEVATED WATER STORAGE TANK  \u003Cbr>COMPOSITE ELEVATED TANK  \u003Cbr>GALLON CAPACITY   |  |  |  |\n| BY___  \u003Cbr>DATE  \u003Cbr>DATE  \u003Cbr>CHKD_   | PROJECT NO.   |  |  |\n|  | DWG.   |  | REV.   |\n\nN900A38-73-130  \n9D1102 REV 0  \nN90'SA3d-d9-130  \nBHRYADO  \n| AZMUTH   | DESCRIPTION   |\n| --- | --- |\n|  |  |\n|  | NORTH ARROW   |\n|  | ELECTRIC ENTRANCE   |\n|  | OVERFLOW SPLASH PAD   |\n|  | PERSONNEL DOOR   |\n|  | INLET/OUTLET PIPE   |\n|  | SIGN/L0G0   |\n|  |  |\n\n# ORIENTATION PLAN\n\nGENERAL NOTES    \n1.CONCRETE SUPPORT STRUCTURE DIAMETER AND DIMENSIONS OF FOUNDATION SHALL BEDETERMINED BY THE TANK CONTRACTOR BASED UPON THE SOIL BEARINGSPECIFIED AND THE RECOMMENDATIONS IN THE SOIL REPORT.  \n2.A GALVANIZED LADDER SAFETY DEVICE MEETNG OSHA STANDARDS SHALL BEPROVDED WHEN REQUIRED.  \n3.SEE SPECIFICATIONS FOR OPTIONAL ACCESSORIES AND ALTERNATE ITEMS.  \n4.ALL LADDERS,LANDINGS,AND ASSOCIATED COMPONENTS INSTALLED INSIDETHE CONCRETE SUPPORT STRUCTURE SHALL BE HOT-DIPPED GALVANIZED  \n\n| MCDERMOTT   |  |  |  |\n| --- | --- | --- | --- |\n| GENERAL PLAN  \u003Cbr>ELEVATED WATER STORAGE TANK  \u003Cbr>COMPOSITE ELEVATED TANK  \u003Cbr>GALLON CAPACITY   |  |  |  |\n| BY___  \u003Cbr>DATE  \u003Cbr>DATE  \u003Cbr>CHKD_   | PROJECT NO.   |  |  |\n|  | DWG.   |  | REV.   |\n\n9D1100 REV5  \nINLET/OUTLET PIPE WTH BAR OVER AND REMOVEABLE SILT STOP    \nSIGN OR LOGO(OPTIONAL)  \nMINIMUM 4 SPARE CIRCUITS  \n①0NE AT LOAD CENTER 48”ABOVE FLOOR  \n②ONE ABOVE TOP PLATFORM③0NE IN ACCESS TUBE NEAR TOP HATCHELECTRICAL SCHEMATIC BURIED THRUST BLOCK DETAL(N.T.S.)   \n| MCDERMOTT   |  | CB&l  \u003Cbr>T2B4Gs   |  |\n| --- | --- | --- | --- |\n| DETAILS  \u003Cbr>ELEVATED WATER STORAGE TANK  \u003Cbr>COMPOSITE ELEVATED TANK  \u003Cbr>GALLON CAPACITY   |  |  |  |\n| BY___  \u003Cbr>DATE  \u003Cbr>DATE  \u003Cbr>CHKD_   | PROJECT NO.   |  |  |\n|  | DWG.   |  | REV.   |\n\nTYPICAL PLAN OF LADDERAND INTERMEDIATE PLATFORM  \n9D1101 REV 5  \nCET_DtI05.DGN","cbCailuUT1PtvjVk","https://ap.wps.com/l/cbCailuUT1PtvjVk","pdf",165242,"English","# Orientation Plan\n## Structural Design Components\n## Electrical and Accessory Specifications\n## Installation and Safety Notes","[{\"question\":\"What are the primary factors determining the foundation dimensions for the elevated tank?\",\"answer\":\"The concrete support structure diameter and foundation dimensions are determined by the tank contractor, based on the specified soil bearing capacity and recommendations from the project's soil report.\"},{\"question\":\"What safety standards must the ladder systems comply with?\",\"answer\":\"All galvanized ladder safety devices must meet OSHA standards when required for installation.\"},{\"question\":\"What is the purpose of the internal ladders within the concrete support structure?\",\"answer\":\"Internal ladders provide access to the various levels of the tank and roof; however, the drawings note that inside tank ladders are not recommended for cold climates.\"}]","CBI-Composite-Elevated-Tank-Drawings | PDF"]